• 제목/요약/키워드: Characteristic radiation

검색결과 606건 처리시간 0.039초

공동주택 거실의 냉방방식에 따른 열환경 특성에 관한 연구 (A Study on the Characteristic of the Thermal Environment in the Cooling System at the Apartment)

  • 이무진
    • 한국주거학회논문집
    • /
    • 제10권4호
    • /
    • pp.111-120
    • /
    • 1999
  • The purpose of this study is to evaluate the efficiency of the thermal environment created by the cooling system at the apartment that combines the forced convection cooling(the system reducing humidity from room) with the floor cooling radiation which uses the floor panel from floor heating system, a general residential heating system in Korea. In this study, the combined cooling system in which air supply, spurt temperature difference and interior draft are reduced, is compared with the existing forced convection cooling system. To identify the effect of the comparison concretely, a comparative experiment is carried out on tour conditions, ie, convection cooling, floor radiation convection cooling and floor radiation cooling. Through it the characteristical thermal environment formed within the model room is analyzed, and the conveying system of compressed floor chill and condensation problem are reviewed.

  • PDF

UC-EBG 구조와 Mushroom EBG 구조가 집적된 마이크로스트립 패치 안테나의 방사 특성 비교 (Comparison of the Radiation Characteristic of a Microstrip Patch Antenna integrated with a UC-EBG Structure and a Mushroom EBG Structure)

  • 김태영;김부균;신종덕
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.233-234
    • /
    • 2008
  • Radiation characteristics of a microstrip patch antenna integrated with a UC-EBG (Uniplanar Compact Electromagnetic Bandgap) structure and a Mushroom EBG structure are compared. Radiation characteristics of a patch antenna integrated with a Mushroom EBG structure are better than those of a patch antenna integrated with a UC-EBG structure.

  • PDF

국내 일사량 자원 특성분석 (A Characteristic Analysis of Solar Radiation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.413-416
    • /
    • 2009
  • Since the solar radiation is main input for sizing any solar photovoltaic system and solar thermal power system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. Among some significant results, the yearly averaged horizontal global insolation was turned out 3.61 kWh/$m^2$/day and the yearly mean 5.38 kWh/$m^2$/day of the direct normal insolation was evaluated for clear days.

  • PDF

고에너지 방사선을 이용한 의학용 x-ray 필름 특성연구 (Studies on the Characteristics of Medical X-ray Films Using the High Energy Radiation)

  • 이재성;허훈
    • 한국인쇄학회지
    • /
    • 제20권2호
    • /
    • pp.153-160
    • /
    • 2002
  • Two different commercial brand X-ray films are used for examining possible differences caused by different target distances when the patients are examined with highenergy X-rays. 6MV- and 15MV X-rays are tested at four different target distances. The films on which the radiation amounts are gradually increased using H$_2$O phantoms are developed by an automatic developing machine to be analysed in the image densities. Characteristic curves have similar shapes for different conditions but for the 130cm target distance. ${\gamma}$ values and average image densities per the illuminated radiation are used to analyse the differences.

  • PDF

150W LED등기구 방열을 위한 열 해석에 관한 연구 (A Study on Heat Simulation for Heat Radiation in 150W LED)

  • 소병문
    • 반도체디스플레이기술학회지
    • /
    • 제15권4호
    • /
    • pp.79-85
    • /
    • 2016
  • For long life time and high efficiency, not necessary in improvement of LED chip structure, but also improve heat radiation for decrease heat in LED chip. In this study, efficiency decline factor has been investigated in LED lamp as study heat characteristic, luminance flux and heat resistance. When LED lamp temperature was increased, about 7% loss of luminance flux. In consequence of temperature analysis, width of fin was the most important factor of heat radiation. As a result, secure the enough heat path is very important factor of LED lamp design.

표준실험동에서 중량충격음의 방사 특성 (Radiation Characteristics of Heavy-weight Floor Impact Sounds in a Standard Test Building)

  • 유승엽;정영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.381-384
    • /
    • 2005
  • The purpose of this study is to develop a prediction model for evaluating heavy-weight floor impact sounds in a test building. Three rooms in the test building (slab thickness In and 240mm), which consist of frame concrete structures were tested and modeled. First, the SPL distribution in the receiving room was analyzed by measuring SPL at 90 positions using a bang machine. Then, a vibration model using finite element method is proposed considering the material properties and boundary conditions. In addition, the result of transient analysis was compared with field measurements using a standard heavy-weight impact source. Through a vibro-acoustic simulation program, an acoustic model evaluating the building elements (reflected wall, nor, window and door) was proposed. Finally, validation of the prediction model was conducted by vibro-acoustic analysis with field measurements of noise radiation characteristics in receiving rooms.

  • PDF

상반성 기법과 p-p method를 이용한 구조물 방사소음 유한요소해석 기법 연구 (Study on sound radiation estimation using a reciprocity technique and p-p method by finite element simulation)

  • 유지우;박헌;이지운
    • 한국음향학회지
    • /
    • 제42권1호
    • /
    • pp.1-6
    • /
    • 2023
  • 구조진동 소음 문제의 평가에 있어 방사소음은 중요한 물리적 특성으로 음향 인텐시티 측정으로 확인이 가능하지만, 시간이 오래 걸리고 까다로운 측정 조건 때문에 시험을 꺼리는 경향이 많다. 그 대안으로 시뮬레이션이 사용되고 있으며, 그 정확도도 높다. 문제는 방사소음 파워와 방사효율 같은 중요한 물리량을 얻기 위해서는 이를 계산해 주는 특정한 소프트웨어가 필요하다는 점이다. 본 연구에서는 이런 관점에서 일반적인 유한요소 해석 소프트웨어를 사용하여 방사소음 파워와 방사 효율을 계산하는 후처리 기법을 제안한다. 제안된 두가지 방법은 기본적으로 시험에서 사용하는 방법을 시뮬레이션에 활용하는 것이다. 첫번째 방법은 상반성 기법을 이용하는 것이며, 두번째 방법은 인접한 2개의 위치에서 계산된 음압을 이용하는 방법이다. 두가지 방법이 모두 효과적으로 방사소음 파워를 예측할 수 있음을 보였으며, 그 한계도 설명하였다.

Differential non-linearity correction for successive approximation ADC

  • Yamada, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집(한일합동학술편); 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.847-850
    • /
    • 1987
  • In this paper a new method to correct the differential non-linearity(D NL) error for a successive approximation is proposed. The DNL of ADC is very important characteristic in the field of radiation pulse height analysis or measurement of probability density function. The results of computer simulations are shown to demonstrate the feasibility of the proposed correction method.

  • PDF

이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증 (Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design)

  • 강상식;허승욱;최일홍;전제훈;양승우;김교태;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.547-553
    • /
    • 2017
  • 현재 의료분야에서는 방사선 차폐체로서 납(Pb)이 널리 쓰이고 있다. 하지만 납은 무게가 매우 무거워 납치마 등의 방호복은 장시간 착용이 어려우며, 인체에 치명적인 납 중독의 위험이 상시 가지고 있다는 문제점을 가지고 있다. 이러한 문제점을 해결하고자 납을 대체 할 수 있는 물질에 대한 많은 연구가 진행되고 있다. 현재 납의 대체물질로써 대표적인 바륨(Ba)과 요오드(I) 등은 우수한 차폐능을 가지고 있지만, 30keV 근처의 에너지 영역에서 특성 X선을 방출하는 특성을 가지고 있다. 환자나 방사선 종사자의 경우 차폐체를 인체에 접촉하고 있는 경우가 많으므로 차폐체에서 발생되는 특성 X선이 인체에 직접 조사되어 방사선 피폭을 증가시킬 위험이 매우 높다. 본 연구에서는 바륨(Ba)과 요오드(I)등에서 발생되는 특성 X선을 제거하기에 적절한 이중구조 차폐체를 방사선 수송코드 중 하나인 FLUKA 수송코드를 개발하여 선행연구로서 진행된 MCNPX 시뮬레이션과 비교 분석하여 이중구조 차폐체의 차폐율에 대한 신뢰성을 검증하고자 하였다. MCNPX와 FLUKA를 이용하여 황산바륨($BaSO_4$)과 산화비스무스($Bi_2O_3$)로 이루어진 다양한 두께조합의 이중구조 차폐체를 설계하였으며, IEC61331-1에 제시된 모식도를 기하학적으로 동일하게 시뮬레이션 상에 구현하였다. 또한, 120 kVp의 연속 X선 스펙트럼에 대한 차폐체의 투과스펙트럼과 흡수선량을 납과 비교 평가하였다. 평가결과, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$$0.1mm-BaSO_4/0.5mm-Bi_2O_3$ 구조에서는 33 keV와 37 keV의 특성 X선을 모두 흡수하였으며, 90 keV 이상의 고에너지 X선에 대해서도 납과 거의 유사한 차폐효율을 보였다. 또한, FLUKA의 수송코드는 33 keV 이하에서는 cut-off 가 발생하여 저에너지 X선 광자에 대한 전산모사에 제약이 있지만, 40 keV 이상의 고에너지 영역에서 MCNPX와의 상대오차가 6 % 이내로 신뢰성이 매우 우수하다는 것을 확인할 수 있었다.