• Title/Summary/Keyword: Characteristic radiation

Search Result 611, Processing Time 0.027 seconds

A Effect on Physiological Metabolism of Microorganism Which Irradiated by Non-ionization Radiation (비 전리 방사선을 조사한 미생물에서 생리적 대사에 미치는 영향)

  • Ko, In-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.381-387
    • /
    • 2018
  • A Effect on physiological metabolism of microorganism which irradiated by visible light of non-ionization radiation(12,000 Lux) was investigated. The microorganism used in this experiment was a Rhodospirillum rubrum KS-301 of chemosynthetic microorganism. Batch fermentation of glucose were implement, and based on the data resulted from the fermentation. First, physiological characteristic of microorganism which was not irradiated was investigated. As a result, the decrease of the residual quantity of the substance(5.03 g/L - 2.17 g/L) was increased with the quantity of the bacteria(1.08 g/L - 3.14 g/L)and the quantity of the hydrogenous production(0.186 g - 0.3 g) respectively. Second, physiological characteristic of microorganism which was irradiated was investigated. As a result, the decrease of the residual quantity of the substance(13.17 g/L - 5.2 g/L) was increased with the quantity of the bacteria(4.7 g/L - 10.57 g/L)and the quantity of the hydrogenous production(0.186 g - 0.3 g) respectively. As the physiological characteristic of microorganism which was irradiated by visible light of non-ionization radiation(12,000 Lux) was active with its life, but the cell damages irradiated by with gamma-ray, X-ray, electron-ray in ionization radiation were appeared at cell.

Radiation Therapy Result of Polymorphic Reticulosis (다형성 세망증(Polymorphic Reticulosis)의 방사선 치료 성적)

  • Chung, Eun-Ji;Kim, Gwi-Eon;Park, Young-Nyun
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.83-90
    • /
    • 1993
  • During the period from January, 1975, to June, 1989, one hundred patients with histopathologically proven polymorphic reticulosis in the upper respiratory tract were treated with radiation therapy and the analysis of treatmemt results was undertaken. One hundred patients (69 males, 31 females) with a mean age of 46 years (range 12-79 years) were presented. Nasal cavity was the most frequent site of involvement ($56{\%}$), and 44 cases had multifocal sites of involvement. The incidence of cervical lymph node metastasis at initial diagnosis was $24{\%}$. Staging was determined by Ann-Arbor classification, retrospectively. The number of patients of stage IE, IIE, IIIE and IVE were 35, 60, 1, and 4, respectively. The overall 5 year actuarial survival rates were $38.4{\%}$. The difference in 5 year survival rates between patients with stage IE and IIE, with solitary and multiple, with CR and PR after irradiation were significant statistically. For the analysis of failure patterns, failure sites include the following: local failure alone (30/55=$54.6{\%}$), systemic failure alone (9/55=$16.4{\%}$), both local and systemic failure (16/55=$29.0{\%}$). Retrograde slide review was available in 29 cases of PMR with respect to histopathologic bases, and immunohistochemical studies were performed using MT1 and DACO-UCHL-1 as T-cell markers, MB2 as a B-cell marker and alpha-1-antichymotrypsin as a histiocytic markers. All that 29 cases showed characteristic histologic features similar to those of peripheral T-cell lymphoma and showed positive reactio to the T-cell marker. These findings suggest strongly that quite a significant portion of PMR may be in fact T-cell lymphoma.

  • PDF

Effects of Plasticizer to Radioresistance and Electrical Conductivity of Irradiated Polyvinylchlorde (방사선(放射線)으로 조사(照射)된 Polyvinylchloride의 내방사성(耐放射性) 전기전도도(電氣傳導度)에 가소제(可塑劑)가 미치는 영향(影響))

  • Kim, Bong-Heup
    • Journal of Radiation Protection and Research
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 1978
  • In order to investigate corelation between contents of dioctylphthalate in polyvinylchloride blent dibutyl tin dilaulate with dibutyl tin maleate as stabilizer and the behaviors of radiation resistance as well as electrical conductivity on irradiated specimens, several observations were carried out. A characteristic peak observed in the range of $1,540-1,640cm^{-1}$ on infrared spectra shows such a sensitive response to radiation as the intensity decreases with increasing doses and that this tendency strongly depressed in the presence of plasticizer. It is seemingly attributed for origin of the peak to the existence of RCOO- ion resulting from dissociation of stabilizere, further the depressive effect of decreasing peak intensity influenced by radiation seems to be caused by resonance absorption in benzen ring being a consistituent of plasticizer. It is also suggestive to be use the peak behavior influenced by radiation as a criterion for the evaluation of radiation resistance of PVC. Further the results obtained from electrical conductivity measurement also exhibit reasonable characteristics explainable with views used for the interpretation of the peak behavior mentioned previousely.

  • PDF

Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study

  • Cheon, Bo-Wi;Yoo, Dohyeon;Park, Hyojun;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Hong, Bong Hwan;Chung, Heejun;Min, Chul Hee
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1970-1978
    • /
    • 2021
  • The aim of this study was to optimize the target, moderator, and collimator (TMC) in a neutron beam generator for the accelerator-based BNCT (A-BNCT) system. The optimization employed the Monte Carlo Neutron and Photon (MCNP) simulation. The optimal geometry for the target was decided as the one with the highest neutron flux among nominates, which were called as angled, rib, and tube in this study. The moderator was optimized in terms of consisting material to produce appropriate neutron energy distribution for the treatment. The optimization of the collimator, which wrapped around the target, was carried out by deciding the material to effectively prevent the leakage radiations. As results, characteristic of the neutron beam from the optimized TMC was compared to the recommendation by the International Atomic Energy Agent (IAEA). The tube type target showed the highest neutron flux among nominates. The optimal material for the moderator and collimator were combination of Fluental (Al203+AlF3) with 60Ni filter and lead, respectively. The optimized TMC satisfied the IAEA recommendations such as the minimum production rate of epithermal neutrons from thermal neutrons: that was 2.5 times higher. The results can be used as source terms for shielding designs of treatment rooms.

Study on Performance Enhancement of Microstrip Antenna Using EBG Structure (EBG 구조를 이용한 마이크로스트립 안테나의 성능 향상에 관한 연구)

  • Yoon, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.1
    • /
    • pp.44-52
    • /
    • 2014
  • In this study, the influence of the near field, far field and radiation directivity of microstrip patch antenna when is used mushroom EBG(Electromagnetic Band Gap) as ground is investigated. Using characteristic of dispersion diagram of mushroom EBG, we calculated forbidden band(2.36GHz-2.85GHz) given mushroom type EBG microstrip antenna(2.45GHz) having 2-layer EBG that is operating within forbidden band. In oder to conform performance enhancemen of antenna using EBG ground, we have compared with the antenna using PEC(Perfect Electric Conductor) ground. We could know about 2.74dB increment of the radiation directivity, because EBG can suppress surface wave that is generated at interfaces of the dielectrics-conductor.

A study on the UWB Antenna Design Techniques for Improving Pulse Fidelity (펄스 충실도 개선을 위한 UWB 안테나 설계기법 연구)

  • Kim, Jung-Min;Kang, Eun-Kyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.299-307
    • /
    • 2013
  • In this paper, design of UWB Antenna which propagate impulse by pulse fidelity and distortion equation was induced and applied. UWB Antenna which has directional characteristic in UWB band should have low radiation loss and impulse radiation distortion. As a result, the paper designed wide band impedance transformer and microstrip slotline transit region structured antenna feeder line. By using the fabricated UWB antenna, the radiation pattern was measured in the radio anechoic chamber. Pulse fidelity of impulse radiation show good results more than 93% within ${\pm}30^{\circ}$ beam width.

Risk Relationship of Cataract and Epilation on Radiation Dose and Smoking Habit

  • Tomita, Makoto;Otake, Masanori;Moon, Sung-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1349-1364
    • /
    • 2006
  • An analytic approach that provides explicit estimates of risk on cataract and epilation data is evaluated by reasonableness of conceivable relative risk models regarding a simple, odds, logistic or Gompertz regression method, assuming a binomial distribution. In these analyses, we apply relative risk models with two thresholds between epilators and nonepilators from a highly characteristic lesion of which radiation cataract does not occur around 2 gray for a single acute exposure. The risk models are fitted to the data assuming 10 as a constant relative biological effectiveness of neutron. The likelihood of observing the entire data set in these models fitted is evaluated by an individual binary-response array. Estimation of a threshold with or without severe epilation and the 100 ($1-\alpha$)% confidence limits are derived from the maximum likelihood approach. The relative risk model with two thresholds can be expressed as a formula with structure of Background $\times$ RR, where RR includes threshold models with or without epilation. The radiosensitivity of ionizing radiation to cataracts has been examined for the relationship between epilators and nonepilators.

  • PDF

A Study on Thermal Characteristics of Stratospheric Airship Considering Radiation Heat Transfer (복사 열전달에 의한 성층권 무인 비행선의 열 특성 연구)

  • Kim Seung-Min;Lee Sang-Myeong;Roh Tae-Seong;Choi Dong-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.285-288
    • /
    • 2005
  • A Stratospheric airship should stay long to achieve its original mission. Meanwhile, to obtain what the solar radiation and heat transfer have an effect on Stratospheric condition, heat analysis has been done. For this work, Stratospheric heat condition's been examined and for the numerical analysis, by using Gridgen, grids of airship have been generated. And by using STAR-CD, the study about heat characteristic of airship model was carried out. Especially, with changing the position of the Sun, the temperature change of the airship body was focused on. With this background, the possibility of realizing the simulation of the effects solar radiation have on the Stratospheric airship.

  • PDF

Design of Tapered Slot Antenna for UWB Communications (UWB 통신을 위한 테이퍼드 슬롯 안테나 설계)

  • Kim, Sun-Woong;Choi, Dong-You
    • Smart Media Journal
    • /
    • v.4 no.4
    • /
    • pp.64-69
    • /
    • 2015
  • In this paper, we have proposed a tapered slot antenna for UWB communication system. The tapered slot antenna has directional radiation and broad bandwidth. Proposed tapered slot antenna is designed using Ansys Inc. HFSS and its VSWR, return los, and radiation pattern is analyzed. Operating band of the antenna were satisfied -10 dB S11 and $VSWR{\leq}2$ in 2.7 ~ 4.8 GHz band. The radiation pattern of the antenna is showed in E-plane (YZ plane) and the H-plane (XZ plane) and the highest gain of 7.3 dBi is seen at 4.5 GHz. Therefore, proposed tapered slot antenna has wide bandwidth characteristic and directional for location awareness.

CHARACTERISTICS OF FABRICATED SiC RADIATION DETECTORS FOR FAST NEUTRON DETECTION

  • Lee, Cheol-Ho;Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Park, Hyeon-Seo;Kim, Gi-Dong;Park, June-Sic;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.70-74
    • /
    • 2012
  • Silicon carbide (SiC) is a promising material for neutron detection at harsh environments because of its capability to withstand strong radiation fields and high temperatures. Two PIN-type SiC semiconductor neutron detectors, which can be used for nuclear power plant (NPP) applications, such as in-core reactor neutron flux monitoring and measurement, were designed and fabricated. As a preliminary test, MCNPX simulations were performed to estimate reaction probabilities with respect to neutron energies. In the experiment, I-V curves were measured to confirm the diode characteristic of the detectors, and pulse height spectra were measured for neutron responses by using a $^{252}Cf$ neutron source at KRISS (Korea Research Institute of Standards and Science), and a Tandem accelerator at KIGAM (Korea Institute of Geoscience and Mineral Resources). The neutron counts of the detector were linearly increased as the incident neutron flux got larger.