• Title/Summary/Keyword: Channel Image

Search Result 1,033, Processing Time 0.03 seconds

Motion Vector Recovery Scheme for H.264/AVC (H.264/AVC을 위한 움직임 벡터 복원 방법)

  • Son, Nam-Rye
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.5
    • /
    • pp.29-37
    • /
    • 2008
  • To transmit video bit stream over low bandwidth such as wireless channel, high compression algorithm like H.264 codec is exploited. In transmitting high compressed video bit-stream over low bandwidth, packet loss causes severe degradation in image quality. In this paper, a new algorithm for recovery of missing or erroneous motion vector is proposed. Considering that the missing or erroneous motion vectors in blocks are closely correlated with those of neighboring blocks. Motion vector of neighboring blocks are clustered according to average linkage algorithm clustering and a representative value for each cluster is determined to obtain the candidate motion vector sets. As a result, simulation results show that the proposed method dramatically improves processing time compared to existing H.264/AVC. Also the proposed method is similar to existing H.264/AVC in terms of visual quality.

Estimation of morphological change using waterline method in the Ganghwado tidal flats

  • Lee, Yoon-Kyung;Ryu, Joo-Hyung;Eom, Jin-Ah;Jo, Min-Jeong
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.22-24
    • /
    • 2007
  • Waterline extraction is the one of widely used methods for studying changes in tidal flat environment and coastlines using multi-temporal optical images such as Landsat TM and Landsat ETM+. High dynamics of tidal currents and land reclamation which accelerate sedimentation and/or erosion cause waterline change in tidal flats. The amount of sediment deposited or eroded can be evaluated by precisely estimating waterline changes in tidal flats. The objective of this study is to detect the change of waterlines during 17 years and analyze the trends of erosion and sedimentation in the study areas. The Ganghwado tidal flat on the west coast of the Korean Peninsula was selected. The study area is famous for high dynamics of tidal currents and vast tidal flats. Land reclamation which has been carried out on a large scale is also considered as one of elements that have accelerated the environmental changes in this tidal flat. In this study, we acquired 26 waterlines from Landsat TM and Landsat ETM+ images. We extracted the waterline from each satellite image to generate a digital elevation map (DEM) which was used for reference and to compare with the other waterline which was extracted from DEM having a same tide. The result of comparison well depicted the areas of dominant sedimentation and erosion, and general trends of sedimentation and erosion according to sub-regions are also revealed during the investigation time. Results showed that erosion during a decade was dominant at the west of the Southern Ganghwado tidal flat, while sedimentation was dominant at the wide channel between the Southern Ganghwado tidal flat and the Yeongjongdo tidal flat. This area has been commonly affected by high currents and sedimentation energy. Although we were not able to verify the accuracy of the waterline changes, this result clearly showed the waterline change and therefore, the waterline extraction method used in this study has proven as an effective tool for long term tidal change estimation.

  • PDF

Comparison of Algorithms for Sea Surface Current Retrieval using Himawari-8/AHI Data (Himawari-8/AHI 자료를 활용한 표층 해류 산출 알고리즘 비교)

  • Kim, Hee-Ae;Park, Kyung-Ae;Park, Ji-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.589-601
    • /
    • 2016
  • Sea surface currents were estimated by applying the Maximum Cross Correlation (MCC), Zero-mean Sum of Absolute Distances (ZSAD), and Zero-mean Sum of Squared Distances (ZSSD) algorithms to Himawari-8/Advanced Himawari Imager (AHI) thermal infrared channel data, and the comparative analysis was performed between the results of these algorithms. The sea surface currents of the Kuroshio Current region that were retrieved using each algorithm showed similar results. The ratio of errors to the total number of estimated surface current vectors had little difference according to the algorithms, and the time required for sea surface current calculation was reduced by 24% and 18%, relative to the MCC algorithm, for the ZSAD and ZSSD algorithms, respectively. The estimated surface currents were validated against those from satellite-tracked surface drifter and altimeter data, and the accuracy evaluation of these algorithms showed results within similar ranges. In addition, the accuracy was affected by the magnitude of brightness temperature gradients and the time interval between satellite image data.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.

Protein Expression of Mouse Uterus in Post-Implantation

  • Kim, Hong-Rye;Han, Rong-Xun;Kim, Myung-Youn;Diao, Yunfei;Park, Chang-Sik;Jin, Dong-Il
    • Reproductive and Developmental Biology
    • /
    • v.33 no.4
    • /
    • pp.237-242
    • /
    • 2009
  • Pregnancy is a unique event in which a fetus develops in the uterus despite being genetically and immunologically different from the mother, and the underlying mechanisms remain poorly understood. To analyze the differential gene expression profiles in nonpregnant and 7 days post coitus (dpc) pregnant uterus of mice, we performed a global proteomic study by 2-D gel electrophoresis (2-DE) and MALDI-TOF-MS. The uterine proteins were separated using 2-DE, Approximately 1,000 spots were detected on staining with Coomassie brilliant blue. An image analysis using Melanie III (Swiss Institute for Bioinformatics) was performed to detect variations in protein spots between pregnant and nonpregnant uterus. Twenty-one spots were identified as differentially expressed proteins, of which 10 were up-regulated proteins such as alpha-fetoprotein, chloride intracellular channel 1, transgelin, heat-shock protein beta-1, and carbonic anhydrase II, while 11 were down-regulated proteins such as X-box binding protein, glutathione S-transferase omega 1, olfactory receptor Olfr204, and metalloproteinase-disintegrin domain containing protein TECADAM. Most of the identified proteins appeared to be related with catabolism, cell growth, metabolism, regulation, cell protection, protein repair, or protection. Our results uncovered key proteins of mouse uterus involved in pregnancy.

Usefulness of the High B-value DWI in Brain Tumors (뇌종양 확산강조영상에서 High B-value의 유용성 평가)

  • Kim, Jin-tae;Byun, Jae-Hu;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports (DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF

The Effect of Sohabhyangwon(蘇合香元) on Regional Cerebral Blood Flow and Area of Cerebral Infarction in the Experimentally induced Cerebral Infarction in Rats (소합향원(蘇合香元)이 실험적(實驗的) 뇌경색(腦梗塞) 흰쥐의 국소뇌혈류량(局所腦血流量) 및 경색(梗塞) 면적에 미치는 영향(影響))

  • Choi, Eun-Jeong;Shin, Gil-Cho;Lee, Won-Chul
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.456-469
    • /
    • 1997
  • The cerebral infarction arised from occulsion of cerebral artery has a high mortality rate and fatal sequelae. Sohabhyangwon(蘇合香元) is generally regarded to have a effect of walking up the patient from unconsiousness and promoting the flow of Qj(氣) by warming channel. METHOD The purpose of this study is to find out the effections of Sohabhyangwon(蘇合香元) on regional cerebral blood flow and relative cerebral infarction area in the experimentally induced infartion in rats In this experiment, 12 Spraque-Dawley rats weighting 280-350g were used. Cerebral ischemia induced by intraluminal suture technique of Kozumi's and Zea-Longer's method. $Co_{2},\;O_2$, pH, arterial blood pressure in rats were checked by Blood Gas Analyzer every 30 minutes for 2 hours. And regional cerebral blood flow were checking by hydrogen clearance technique, cerebral infarcted area was megsured by Image Analysis System. RESULTS 1. During the experiment, $CO_{2},\;O_2$, pH, arterial blood pressure in rats had no change in both sample group and control group. 2. Cortical cerebral blood flow decreased at same rate in both sample group and control group after inducing cerebral infarction. 3. On comparison of relative cerebral infarcted area, Sohabhyangwon(蘇合香元) perfused group showed a significant decrease. CONCLUSION According to the result above, Sohabhyangwon has a protection effect on cranial nerve and-has no effect on cerebral blood flow.

  • PDF

Depth Map Based Distributed Multi-view Video Coding Scheme through an Efficient Side Information Generation (효율적인 보조 정보 생성을 통한 깊이지도 기반의 분산 다시점 비디오 코딩 기법)

  • Yoo, Ji-Hwan;Lee, Dong-Seok;Kim, Tae-June;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1093-1103
    • /
    • 2009
  • In this paper, we propose a new depth map based distributed multi-view video coding algorithm through an efficient side information generation. A distributed video coding scheme corrects errors between an original image and side information generated at a decoder by using channel coding techniques. Therefore, the more accurate side information is generated, the better performance of distributed video coding scheme is achieved. In the proposed algorithm, a distributed video coding scheme is applied to multi-view video coding based on depth map. Side information is also generated from images of adjacent views through 3D warping by using a depth map and is also combined with MCTI(motion compensated temporal interpolation) which uses images on a temporal axis, and 3D warping. Experimental results show that side information generated by using the proposed algorithm has 0.97dB better average PSNR compared with using MCTI and 3D warping separated. In addition, 8.01% of average bit-rate has been decreased while the same PSNR in R-D curves is kept.