• Title/Summary/Keyword: Channel Calibration

Search Result 167, Processing Time 0.027 seconds

The Dual-Channel, Pulse-Counting Pierce-Blitzstein Photometer-The PBPHOT: Our Last Paper with Bob Koch, and Additional Technical History

  • Ambruster, Carol;Hull, Tony;Koch, Robert H.;Mitchell, Rich;Wolf, George;Smith, Bob
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.2
    • /
    • pp.195-198
    • /
    • 2012
  • The dual channel Pierce-Blitzstein photometer (PBPHOT) was productively used at the Flower and Cook Observatory to provide 60 years of study of binary systems and other cosmic objects. We review the history of this instrument, discuss its calibration, and recall some personal and professional interactions with Professor Robert H. Koch.

An RSS-Based Localization Scheme Using Direction Calibration and Reliability Factor Information for Wireless Sensor Networks

  • Tran-Xuan, Cong;Koo, In-Soo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.1
    • /
    • pp.45-61
    • /
    • 2010
  • In the communication channel, the received signal is affected by many factors that can cause errors. These effects mean that received signal strength (RSS) based methods incur more errors in measuring distance and consequently result in low precision in the location detection process. As one of the approaches to overcome these problems, we propose using direction calibration to improve the performance of the RSS-based method for distance measurement, and sequentially a weighted least squares (WLS) method using reliability factors in conjunction with a conventional RSS weighting matrix is proposed to solve an over-determined localization process. The proposed scheme focuses on the features of the RSS method to improve the performance, and these effects are proved by the simulation results.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

A Robotic Vision System for Turbine Blade Cooling Hole Detection

  • Wang, Jianjun;Tang, Qing;Gan, Zhongxue
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.237-240
    • /
    • 2003
  • Gas turbines are extensively used in flight propulsion, electrical power generation, and other industrial applications. During its life span, a turbine blade is taken out periodically for repair and maintenance. This includes re-coating the blade surface and re-drilling the cooling holes/channels. A successful laser re-drilling requires the measurement of a hole within the accuracy of ${\pm}0.15mm$ in position and ${\pm}3^{\circ}$ in orientation. Detection of gas turbine blade/vane cooling hole position and orientation thus becomes a very important step for the vane/blade repair process. The industry is in urgent need of an automated system to fulfill the above task. This paper proposes approaches and algorithms to detect the cooling hole position and orientation by using a vision system mounted on a robot arm. The channel orientation is determined based on the alignment of the vision system with the channel axis. The opening position of the channel is the intersection between the channel axis and the surface around the channel opening. Experimental results have indicated that the concept of cooling hole identification is feasible. It has been shown that the reproducible detection of cooling channel position is with +/- 0.15mm accuracy and cooling channel orientation is with +/$-\;3^{\circ}$ with the current test conditions. Average processing time to search and identify channel position and orientation is less than 1 minute.

  • PDF

Calibration of Water Velocity Profile in Circular Water Channel Using Particle Image Velocimetry (PIV를 이용한 회류수조의 유속 분포 교정에 관한 연구)

  • Suh, Sung-Bu;Jung, Kwang-Hyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.23-27
    • /
    • 2011
  • This experimental study was performed to find rpms of the impeller and the surface flow accelerator to make a uniform velocity vertical distribution in the circular water channel. PIV technique was employed to measure the water velocity profiles into the water depth from the free surface. The number of instantaneous velocity profiles was decomposed into mean and turbulence velocity components, and the distribution of velocity fluctuation and turbulence intensity were computed for each experimental condition. From these results, the velocity uniformity was quantitatively determined to present the flow quality in the measuring section of the circular water channel. It has been shown that the proper operation of the surface flow accelerator would make the uniform velocity profiles and reduce the velocity fluctuation near the free surface.

A Study on the Calibration of GaAs-based 0.1-$\mu\textrm{m}$ $\Gamma$-gate MHEMT DC/RF Characteristics for the Development and Fabrication of over-100-GHz Millimeter-wave HEMT devices (100GHz 이상의 밀리미터파 HEMT 소 제작 및 개발을 위한 GaAs기반 0.1$\mu\textrm{m}$ $\Gamma$-게이트MHEMT의 DC/RF 특성에 대한 calibration 연구)

  • 손명식;이복형;이진구
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.751-754
    • /
    • 2003
  • Metamorphic HEMTs (MHEMTs) have emerged as excellent challenges for the design and fabrication of high-speed HEMTs for millimeter-wave applications. Some of improvements result from improved mobility and larger conduction band discontinuity in the channel, leading to more efficient modulation doping, better confinement, and better device performance compared with pseudomorphic HEMTs. We have studied the calibration on the DC and RF characteristics of the MHEMT device using I $n_{0.53}$G $a_{0.47}$As/I $n_{0.52}$A1$_{0.48}$As modulation-doped heterostructure on the GaAs wafer. For the optimized device performance simulation, we calibrated the device performance of 0.1-${\mu}{\textrm}{m}$ $\Gamma$-gate MHEMT fabricated in our research center using the 2D ISE-DESSIS device simulator. With this calibrated parameter set, we have obtained very good reproducibility. The device simulation on the DC and RF characteristics exhibits good reproducibility for our 0.1-${\mu}{\textrm}{m}$ -gate MHEMT device compared with the measurements. We expect that our calibration result can help design over-100-GHz MHEMT devices for better device performance.ormance.

  • PDF

Measurement of local wall temperature and heat flux using the two-thermocouple method for a heat transfer tube

  • Ahn, Taehwan;Kang, Jinhoon;Jeong, Jae Jun;Yun, Byongjo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1853-1859
    • /
    • 2019
  • The two-thermocouple method was investigated experimentally to evaluate its accuracy for the measurement of local wall temperature and heat flux on a heat transfer tube with an electric heater rod installed in an annulus channel. This work revealed that a thermocouple flush-mounted in a surface groove serves as a good reference method for the accurate measurement of the wall temperature, whereas two thermocouples installed at different depths in the tube wall yield large bias errors in the calculation of local heat flux and wall temperature. These errors result from conductive and convective changes due to the fin effect of the thermocouple sheath. To eliminate the bias errors, we proposed a calibration method based on both the local heat flux and Reynolds number of the cooling water. The calibration method was validated with the measurement of local heat flux and wall temperature against experimental data obtained for single-phase convection and two-phase condensation flows inside the tube. In the manuscript, Section 1 introduces the importance of local heat flux and wall temperature measurement, Section 2 explains the experimental setup, and Section 3 provides the measured data, causes of measurement errors, and the developed calibration method.

Development of an energy and efficiency calibration method for stilbene scintillators

  • Kim, Chanho;Kim, Jaehyo;Hong, Wooseong;Yeom, Jung-Yeol;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3833-3840
    • /
    • 2022
  • A method for calibrating the energy scale and detection efficiency of stilbene scintillators is presented herein. This method can be used to quantitatively analyze the Compton continuum of gamma-ray spectra obtained using such scintillators. First, channel-energy calibration was conducted by fitting a semi-empirical equation for the Compton continuum to the acquired energy spectrum and a new method to evaluate the intrinsic detection efficiency, called intrinsic Compton efficiency, of stilbene scintillators was proposed. The validity of this method was verified by changing experimental conditions such as the number of sources being measured simultaneously and the detector-source distance. According to the energy calibration, the standard error for the estimated Compton edge position was ±1.56 keV. The comparison of the intrinsic Compton efficiencies calculated from the single- and two-source spectra showed that the mean absolute difference and the mean absolute percentage difference are 0.031 %p and 0.557%, respectively, demonstrating reasonable accuracy of this method. The feasibility of the method was confirmed for an energy range of 0.5-1.5 MeV, showing that stilbene scintillators can be used to quantitatively analyze gamma rays in mixed-radiation fields.

Performance Analysis of a Noncoherent OOK UWB System Based on Power Detection in Indoor Wireless Channels (실내 무선 채널에서 전력검출 기반 Noncoherent OOK UWB 시스템의 성능 분석)

  • Oh Jongok;Yang Suckchel;Shin Yoan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.11C
    • /
    • pp.1498-1509
    • /
    • 2004
  • In this paper, we evaluate the performance of a noncoherent OOK (On-Off Keying) UWB (Ultra Wide Band) system based on power detection with noise power calibration and noise power windowing for ubiquitous sensor network applications in typical indoor wireless channels. Utilizing noise power calibration and noise power windowing, the current noise information can be initially or adaptively provided to determine suitable detection threshold value for signal demodulation. Simulation results show that the noncoherent OOK UWB system using noise power calibration achieves good BER (Bit Error Rate) performance which is favorably comparable to that of the system using the ideal adaptive threshold, while maintaining simple receiver structure. However, despite the serious loss of the data transmission rate, the performance improvement by noise power windowing is not so remarkable. furthermore, these performance results are similarly maintained in BEE 802.15 Task Group 3a UWB indoor channel model, and it is also revealed that the BER performance can be significantly improved by increasing the pulse repetition rate.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.