• Title/Summary/Keyword: Change Rate

Search Result 9,316, Processing Time 0.037 seconds

A study on the color change switch and electrochemical doping of polythiophene (Polythiophene의 전기화학적 도핑과 변색 스위치에 관한 연구)

  • 구할본;김주승;김현철;김종욱
    • Electrical & Electronic Materials
    • /
    • v.9 no.2
    • /
    • pp.165-173
    • /
    • 1996
  • We prepared polythiophene and poly(3-methylthiophene) films, known as conducting polymer, by electrochemical method. Polythiophene and poly(3-methylthiophene) films were doped and undoped dopant for the studing the understanding of doping mechanism and possible application to the color change switch. We observed that the anodic, cathodic wave and absorption spectra were slightly changed during doping and undoping process in polythiophene. It shows that doping and undoping process were showed some difference by the appearance and disappearance of polaron and bi-polaron. In the relation of the peak of oxidative current density and potential sweep rate of cyclic voltammograms, the amount of dopant in polythiophene film was homogeneously increased at low scan rate. This also can be applied to the poly(3-methlythiophene).

  • PDF

Structural Change in Real Estate Market (IMF 이후의 부동산시장의 구조변화)

  • 서승환;김갑성
    • Journal of the Korean Regional Science Association
    • /
    • v.15 no.3
    • /
    • pp.33-51
    • /
    • 1999
  • After the 1997 currency crisis, the real estate prices had been rapidly dropped and the deregulation in the Korean real estate merket has been performed. It is analyzed whether these transactions caused a structural change in real estate market, or not. The Pettitt test shows there exists a turing point in real estate prices in 1998. It is found that the degrees of co-movement between the change in real estate prices and real GDP growth rate are increased. Consequently, the factor, represented as real GDP growth rate, determining the market fundamental of real estate prices will effect on the behavioral pattern and the real estate prices in the long run. While the factors determining the portfolio selection behaviors, such as interest rate and stock prices, will cause short-term variations.

  • PDF

Biaxial Compressive Deformation Characteristics and Microstructure Change in a Round Copper Pipe (원형 동관의 2축압축 변형특성 및 조직변화에 관한 연구)

  • Yoo, C.K.;Won, S.T.
    • Transactions of Materials Processing
    • /
    • v.22 no.2
    • /
    • pp.67-73
    • /
    • 2013
  • The deformation characteristics and microstructure changes in a round copper pipe under biaxial compression was studied using a horizontal compression die. The change of material properties, punch load and deformation behavior were monitored using various compressive deformation rates in the range of 0.5mm/min.~450mm/min. The strains, either tensile or compressive, were estimated from Vickers microhardness test results. The punch load and deformation characteristics of the round copper pipes were found to change greatly at a deformation rate of about 200mm/min. The punch load decreased with increasing compressive deformation rate. The results of numerical simulations agreed well with what was expected from the final microstructure and the hardness profile estimated from the final deformation strains.

Study on the Surface Roughness of the Epoxy resins) (엑폭시 수지의 절삭가공시 표면거칠기에 관한 연구)

  • 김희남
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.64-74
    • /
    • 1996
  • The meachanism for cutting epoxy resins specimens which were specially provided was experimentally investigated to obtain a fine surface finish. the specimens were cut the three-dimensional undrer dry conditions using a lathe. the relationship between the topography of the cut surface due to the change rate of temperature of the cutting condition using sintered carbides (P20, K10, KT150) was investigated. the main results obtained are as follows: 1) The change rate of temperature of the cutting edge is increased in nearly proportion ot cutting speed feed rate depth of cut. 2)The profile of surface roughness were regulated k10 but irregulated P20 KT150. 3) The surface roughness value decreased K10 rather than P20 KT150. 3) The surface roughness value decreased K10 rather than P20 KT 150.4)The cutting resistance increased thrust force rather than cutting force due to the visco-elastic material of epoxy resins.

  • PDF

Design and Performance Test of Valve Operated by ER Fluids (ER 유체로 작동되는 벨브의 제작 및 성능실험)

  • 장성철;염만오
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.1
    • /
    • pp.63-68
    • /
    • 2004
  • Recently ER fluids are put to practical use in fluid power industry field. As only with electrical signal change to the valve in which ER fluid flowing, ER fluid flow is controlled, so devepment of simple ER valves have been tried. In this case a technical problem is to check the pressure drop caused from flow rate change in valves because the pressure drop is very small. In this study ER valves are designed and manufactured, and small pressure drop induced from flow rate change is checked by pressure transducer which is made with appling strain gage. The ER valves and pressure drop check method are considered to be applied to the fluid power industry.

Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers (Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구)

  • 송시홍;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.

Freezing of Water in Von-Kármán Swirling Flow (Von-Kármán 회전 유동 하에서의 물의 결빙)

  • Yoo, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.413-422
    • /
    • 1996
  • Freezing of water in von-$K{\acute{a}}rm{\acute{a}}n$ swirling flow is considered. The transient behavior of the temperature distribution in both solid and liquid phases and freezing rate are determined. The fluid flow induced by the rotation of solid strongly inhibits the freezing process. The thickness of frozen layer is inversely proportional to the square root of the angular velocity of solid. As the angular velocity or initial liquid temperature becomes larger, the freezing process is more strongly inhibited by the fluid flow. When phase change is present, the transient heat transfer rate is greater than the case with no phase change.

  • PDF

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

Melting of Ice Inside a Horizontal Cylinder under the Volume Change (수평원관내 체적변화를 고려한 얼음의 용용시 전열특성에 관한 연구)

  • 조남철;김동춘;이채탈;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1266-1274
    • /
    • 2001
  • Heat transfer phenomena during melting process of the phase change material (ice) was studied by numerical analysis and experiments. In a horizontal ice storage tube, the natural convection caused an increase in melting rate. However, the reduction of the heating surface area caused a decrease in melting rate. Therefore, during the melting process of ice in a horizontal cylinder, the reduction of the heating surface area should be considered. Under the same heating wall and initial water temperature condition, the melting rate became higher for $V_s/V_tot/=0.545 \;than \;that\; for\; V_s/V_tot$/=1.00 due to the difference in the reduction of heating surface area. A modified melting model considering the equivalent thermal conductivity of liquid phase and volume reduction was proposed. The results of the model were compared with the measured values and found to be in good agreement.

  • PDF

Evaluation of the Contribution Ratio that the Pollution Loads of the Drainage Areas Affect Soyang-lake (배수구역의 유달오염부하량이 소양호 유역에 미치는 기여율 평가)

  • Park, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5363-5368
    • /
    • 2014
  • This study examined contribution rate on the Soyangho Lake watershed based on the flow regime, and seasonal change was evaluated by calculating the delivery pollution load of the drainage area of Soyangho Lake watershed. According to the contribution rate of the drainage area by the flow regime change, Inbukcheon Creek watershed's SS and T-P entry have recorded abnormal Six month flow and a contribution rate of 46% and 51% during the Low-water flow period. At the same time, the T-P recorded a 49.5% contribution rate and a contribution rate of 48.5% during the Low-water flow period. In sequence, Inbukcheon creek's SS entry recorded a comparatively higher contribution rate than the other drainage area, which are 39.6% and 44.3% during the entire season and 53.8% for T-P, as a result of observing the contribution rate based on the seasonal changes. The T-N at the Naerincheon Creek watershed for the entire season recorded a contribution rate between 39.6% and 44.3%. Overall, Inbukcheon Creek watershed's SS and T-P entry and Naerincheon creek's T-N had a high contribution rate on contaminant spill.