• 제목/요약/키워드: Chamber experiment

검색결과 757건 처리시간 0.026초

온돌 온열환경지표 평가방법 (Evaluation Methods on ONDOL Thermal Environmental Index)

  • 김성조
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.101-110
    • /
    • 2022
  • For this purpose, the authors proposed and proved usefulness of the modified mean skin temperature which is integrated mean radiation temperature and the effect of floor contacted heat conduction. The mean radiation temperature is applied form factor between half cross-legged human body and surrounding wall of indoor. In addition the floor contacted heat conduction is applied heat transfer coefficient of half cross-legged human body. Eight Korean young men were targeted for the experiment. From the experiment the authors excerpted physiological reaction and psychological reaction in Ondol environment which is combined physiccal environmental factor of artificial climate chamber, air and floor temperature. As a result of the experiment it is confirmed that heat conduction has more impact than heat exchange from existing research for the heat exchange between half cross-legged human body and surrounding wall in Ondol thermal environment. Thereby, it is proved the effectiveness of the modified mean skin temperature which is added floor contacted temperature to the Ondol thermal environmental evaluation index.

농산물(農産物) 건조(乾燥)를 위(爲)한 태양열(太陽熱) 집열기(集熱機)의 제작(製作) 및 이용(利用)에 관(關)한 연구(硏究) (Design and Utilization of Solar Collector for Drying Agricultural Products)

  • 고학균;금동혁
    • Journal of Biosystems Engineering
    • /
    • 제6권2호
    • /
    • pp.48-57
    • /
    • 1982
  • In order to improve the quality of traditionally sun-dried red peppers and to increase the efficiency of drying performance, three types of solar dryers were designed and built, and drying performance of the solar dryers was compared to traditional sun drying. Results obtained from the experiment are summarized as fallows: 1. The air temperature and relative humidity profiles over a 8-hour period measured at the specified locations in the drying chamber of solar dryers appeared to have large variation in each dryer. The rate of drying increased with the temperature rise in the drying chamber of the solar dryer. 2. In general. drying with solar dryers proceeded faster than traditional sun drying. With A'-type of solar dryer developed in the second experiment it was possible to dry red peppers in seven days from an initial moisture content of 80% to safe storage conditions. The drying time with the A'-type solar drier was 50% shorter compared to traditional sun drying. 3. Red peppers appeared to have an increasing or constant-rate drying period until the weight of the product was reduced to about one half the initial weight, followed by a falling-rate drying period. When the dried red peppers were exposed to the atmospere during the night, the moisture content increased as much as 6%, which is much higher than for the grains. 4. It was suggested from the experiment that either a heat storage system or a supplemental heating system in the solar dryer was desirable for more efficient drying operation. 5. It was shown that the solar dryer developed in this study may be suitable for drying other vegetables and fishes, and also offered additional advantages of saving in drying time, maintaining sanitation and minimizing contamination by dust, insects and unfavorable weather condition.

  • PDF

고온 고압 정적 연소실에서 연소과정에 따른 온도 분포 측정 (Study of spatial temperature distribution during combustion process in a high temperature and pressure constant volume chamber)

  • 김기현
    • 한국산학기술학회논문지
    • /
    • 제18권1호
    • /
    • pp.345-350
    • /
    • 2017
  • 디젤 엔진의 연비와 배기를 개선하고자 하는 노력으로 다운사이징이 강화되고 있다. 이에 따라 엔진의 사이즈는 작아지고, 엔진 연소실 내 온도와 압력은 상승하는 추세이다. 따라서 높은 온도와 압력 조건에서 연료 분무의 발달과정과 연소과정 연구가 매우 중요하다. 본 연구에서는 디젤 엔진 연소실의 고온 고압 환경을 벤치에서 모사해줄 수 있는 정적 연소실을 개발하였다. 정적 연소실은 예혼합기를 연소시켜 순간적으로 온도와 압력을 급격하게 상승시킨 다음, 주변으로의 열전달에 의해 온도와 압력이 감소할 때 시험 목표조건인 온도와 압력 조건에 다다르면, 연료 분사기에 신호를 인가하여 연료분무를 개시하며 쿼츠 창을 통하여 연료 분무를 가시화 한다. 이 때, 정적 연소실 내에 연료 분무가 이루어지는 영역의 온도를 정확히 측정하여 정확한 시험 조건을 형성해야 한다. 본 연구에서는 고속으로 온도를 측정할 수 있는 열전대를 직접 개발 및 제작하여 연소실 내 시공간적 온도분포를 측정하였다. 측정 결과, 전체 체적 온도보다 연료 분무가 개시되는 중심 공간의 온도가 더 높게 나타났으며, 이는 연소실 벽면으로의 열전달 때문임을 확인하였다. 또한 횡방향으로의 온도 편차는 약 10%이내 수준이었으나, 종방향으로 온도편차가 최대 15%수준으로 나타났고 이는 부력으로 인한 고온의 연소가스의 상승효과 때문으로 판단되었다.

소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가 (Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber)

  • 이석조;장성기;김미현;이홍석;임준호;장미;서수연
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.344-354
    • /
    • 2005
  • 최근 들어 실내공기질 악화의 주 오염원인 건축자재에 대한 관심이 고조되면서 건축자재 오염물질 방출시험 자료 구축이 중요하게 됨에 따라, 신뢰성 있는 자료 확보를 위해 건축자재 방출시험 정도 관리에 대한 필요성이 대두되었다. 이에 본 연구는 건축자재 방출시험 성능에 대한 정도관리를 위해 총 휘발성 유기화합물과 포름알데히드에 대하여 기기분석 재현성, 회수율, 검출한계, 중복 및 반복채취 재현성, 파과용량 평가 등을 실시하였다. 기기분석 및 시료채취에 대한 재현성은 20~30% 이내의 양호한 결과를 보였으며, 회수율은 80% 이상으로 나타났으며, 파과 역시 일어나지 않아 소형챔버법에 의한 성능은 전반적으로 만족할 만한 수준을 보였다. 따라서, 소형챔버를 이용한 건축자재 오염물질 방출시험방법은 신뢰성있는 자료를 제공해 줄 수 있을 것으로 판단된다.

Flow-3D 모형을 이용한 순환수취수펌프장 내 흐름현상 연구 (Study for Flow Phenomenon in the Circulation Water Pump Chamber using the Flow-3D Model)

  • 하성원;김태원;최주환;박영진
    • 한국산학기술학회논문지
    • /
    • 제20권4호
    • /
    • pp.580-589
    • /
    • 2019
  • 인도네시아는 전력 공급이 매우 부족한 현실에 처해 있으며, 이에 대한 해결책으로 화력발전소 건설 계획이 증가하고 있다. 화력발전소는 발전에 수반되는 엔진과 장비의 과열을 식히기 위해 냉각수 계통을 필요로 하며, 냉각수 계통 중 순환수 취수펌프장(circulating water pump chamber)은 일반적으로 ANSI (1998) 기준에 따라 설계된다. 본 연구에서는 인도네시아 K-석탄화력발전소의 순환수취수펌프장이 현장 여건상 ANSI (1998)의 확산각 설계기준 $20^{\circ}$를 만족시킬 수 없어, 수리적으로 안정된 흐름 및 구조물이 되도록 3차원 수치모형실험을 수행하였다. 수치모형으로 Flow-3D 모형을 이용하였다. Flow-3D 모형의 적용성을 검토하기 위해 Rodi (1997)의 사각형 구조물 주변에 형성되는 흐름 연구 결과와 금회 수치해석 결과를 비교하였다. 수치해석에서 도출된 종방향 유속 분포는 잘 일치함을 보여주고 있다. 순환수취수펌프장 내 설계유속을 만족시키기 위해 유속 저감에 유리한 사각형 형태의 배플을 적용하였다. 순환수취수펌프장으로 유입되는 유속이 1.5 m/s ~ 2.5 m/s로 분포되는 경우, 배플에서 분리흐름의 각도는 약 $15^{\circ}{\sim}20^{\circ}$로 발생하였다. 이를 고려하여 분리흐름 각도 이하로 하류에 배플을 배치함으로 Inlet bay 설계유속 0.5 m/s 이하를 만족시켰다.

1-D 시뮬레이션을 활용한 핀틀추력기의 성능해석-II : 비정상상태 특성 (Performance Analysis of the Pintle Thruster Using 1-D Simulation-II : Unsteady State Characteristics)

  • 노성현;김지홍;허환일
    • 한국항공우주학회지
    • /
    • 제43권4호
    • /
    • pp.311-317
    • /
    • 2015
  • 본 연구는 공압시험용 핀틀추력기의 비정상상태 특성을 예측하기 위한 1-D 시뮬레이션 적용법을 기술한다. 추력을 제어하기 위해 질량유량, 챔버압력, 노즐출구 압력은 핵심 매개변수이다. 챔버압력은 핀틀 스트로크 변화에 따라 단조롭게 증감하였지만, 추력은 챔버 압력의 변화와 다른 양상을 보였다. 핀틀이 전진할 때 핀틀 속도와 챔버 자유체적이 특정 값을 초과하면 추력 값은 초기에 감소하다가 다시 증가하는 경향을 보였다. 1-D 시뮬레이션은 비정상 상태 특성을 예측하는데 한계가 있지만 실험이나 수치해석 이전에 듀얼벨 노즐과 같은 다양한 고도보정노즐 추력기의 초기 성능 평가에 여전히 유용하다.

Effects of Elevated $CO_2$ and Temperature on Seedling Emergence of Herbs in a Japanese Temperate Grassland

  • Lee, Jae-Seok;Takehisa Oikawa;Shigeru Mariko;Lee, Ho-Joon
    • The Korean Journal of Ecology
    • /
    • 제23권6호
    • /
    • pp.423-429
    • /
    • 2000
  • To understand the effects of elevated $CO_2$ concentration and temperature on seedling emergence of seven herbaceous species, the seedling emergence was monitored between November 1997 and May 1998 using a temperature gradient chamber and a $CO_2$-temperature gradient chamber. Experiment was conducted under current ambient condition (Control plot), 2$^{\circ}C$-warmed condition with ambient $CO_2$ (T2 Plot), 4$^{\circ}C$-warmed condition with ambient $CO_2$ (T4 plot). and 4$^{\circ}C$-warmed condition with 1.8 fold of ambient $CO_2$ (CT4 plot). Species tested in this study were Digitaria adscendens, Echinochloa crus-galli, Panicum bisulcatum, Setaria viridis. Oenothera biennis, Andropogon virginicus, and Imperata cylindrica. Each species often dominates in the herbaceous stage of secondary succession in Japan. The mean seedling emergence times for all species were significantly increased to 23.6 and 32.2 d in the T2 and T4 plot compared to the Control plot, respectively. The most sensitive and insensitive species in seedling emergence time in T2 plot were O. biennis and D. adscendens, respectivel.y, and those in the T4 and CT4 plot were I. cylindrica and D. adscendens, E. crus-galli and A. virginicus, respectively. All experimental species showed no significant difference in the seedling emergence rate between treatments except for O. biennis and I. cylindrica. O. biennis showed a great decrease in the seedling emergence rate from 83.3% in the Control plot to 38.0%, 14.7%, and 29.3% in the T2, T4, and CT4 plot, respectively. Elevated $CO_2$ had very little effect on the seedling emergence. From these observations, it is expected that increased temperature would greatly advance the vegetative recovery time after disturbance through the advancement of seedling emergence time.

  • PDF

정수면 아래 최적 유공부 길이 산정 : 유공 1실 조건 (Estimation of Optimal Slit Length of Perforated Wall below Still Water Level: Single Chamber Condition)

  • 김영택;이종인
    • 한국수자원학회논문집
    • /
    • 제46권4호
    • /
    • pp.327-334
    • /
    • 2013
  • 본 연구에서는 단면수리실험으로 다양한 실험파 조건과 유수실 폭(B)을 변화시키면서 유공부 길이(S)와 반사율의 관계를 검토하여 유공 1실인 유공구조물의 정수면 아래 최적 유공부 길이를 제시하였다. 입사파로 불규칙파를 적용함에 따라 최저 반사계수는 상대 유수실 폭($B/L_s$)이 $B/L_s{\approx}0.15$에서 발생하였다. 유공부 길이와 입사파고와의 관계를 고려한 상대 유공부 길이($S/H_s$)는 $S/H_s{\approx}2.5$에서 최저 반사계수를 보였으며, 이는 정수면 아래 유공부 길이가 입사파고의 약 2.5배일때 최적임을 의미하는 것이다.

LP가스 폭발로부터 화재로의 천이에 관한 연구 (A Study on the Explosion to Fire Transition Phenomena of Liquidfied Petroleum Gas)

  • 오규형;이춘하
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.107-113
    • /
    • 1993
  • Small rectangular explosion chamber of its size 25cmX25cmX32cm with a circular bursting diaphram at the top was used to study the mechanism of gas explosion to fire transition phenomena, the process of ignition of solid combustibles during a gas explosion. To visulize the explosion to fire transition phenomena, transparent acryl window and high speed camera system were used. The test piece of solid combustible in this experiments was a 5cm$\times$5cm square sheet of newspaper which was placed in the explosion chamber filled with a LPG-air mixture. The mixture was ignited by an electric spark at the center of the chamber. Explosion to fire transition phenomena and the behavior of out flow and in flow of gas through the opening yielded by bursting the diaphram was visualized with shlieren system and without shlieren system. Diameter of a bursting dlaphram at the top of the explosion chamber was varied 5cm, 10cm, and 15cm, and the position of test piece were varied with 6 point. Explosion pressure was measured with strain type pressure transducer, and the weight difference of the test piece before and after each experimental run was measured. By comparing the weight difference of solid combustibles before and after the experiment and the behavior of out flow and inflow of gas after explosion, it was found that the possibility of ignition was depends on the LPG-air mixture concentration and the exposure period of test piece to the burnt gas. Test result of this experiments it was found that the main factor of this phenomena are that heat transfer to the test piece, and the pyrolysis reaction of test piece. Based on the results, the mechanism of the explosion to fire transition phenomena were inferred ; gas explosion- heat transfer to solid combustibiles ; pyrolysis reaction of solid combutibles : air inflow ; mixing of the pyroly gas with air ignition.

  • PDF

Construction of a Thermal Vacuum Chamber for Environment Test of Triple CubeSat Mission TRIO-CINEMA

  • Jeon, Jeheon;Lee, Seongwhan;Yoon, Seyoung;Seon, Jongho;Jin, Ho;Lee, Donghun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.335-344
    • /
    • 2013
  • TRiplet Ionospheric Observatory-CubeSat for Ion, Neutron, Electron & MAgnetic fields (TRIO-CINEMA) is a CubeSat with 3.14 kg in weight and 3-U ($10{\times}10{\times}30$ cm) in size, jointly developed by Kyung Hee University and UC Berkeley to measure magnetic fields of near Earth space and detect plasma particles. When a satellite is launched into orbit, it encounters ultra-high vacuum and extreme temperature. To verify the operation and survivability of the satellite in such an extreme space environment, experimental tests are conducted on the ground using thermal vacuum chamber. This paper describes the temperature control device and monitoring system suitable for CubeSat test environment using the thermal vacuum chamber of the School of Space Research, Kyung Hee University. To build the chamber, we use a general purpose thermal analysis program and NX 6.0 TMG program. We carry out thermal vacuum tests on the two flight models developed by Kyung Hee University based on the thermal model of the TRIO-CINEMA satellite. It is expected from this experiment that proper operation of the satellite in the space environment will be achieved.