• 제목/요약/키워드: Cervical fracture

검색결과 118건 처리시간 0.028초

Management of horizontal root fractures by fabrication of canine protected occlusion using composite resin

  • Shin, Joo-Hee;Kim, Ryan Jin-Young
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.180-184
    • /
    • 2012
  • Traumatic injuries of the face often involve root fractures especially in anterior teeth. The prognosis and the treatment of the root fracture depend on the extent of the fracture line, general health and patient compliance. This case report outlines a new conservative trial treatment modality to stabilize the maxillary central incisors with horizontal root fracture on the cervical to middle third by fabricating canine guidance to remove loading on the traumatized maxillary central incisors during eccentric movements and thus inducing spontaneous healing of the fractured line between the fragments. Radiographs after thirty months showed adequate healing with no signs of pathological changes including root resorption, ankylosis or displacement. Long term follow-up revealed that vitality, stability and aesthetics were maintained and the patient was satisfied with the outcome.

두개저 골절과 동반된 외상성 양측성 외전신경 마비 1례 (A Case of Traumatic Bilateral Abducens Nerve Palsy Associated with Skull Base Fracture)

  • 황정인;조진성;이승철;이정훈
    • Journal of Trauma and Injury
    • /
    • 제21권1호
    • /
    • pp.66-69
    • /
    • 2008
  • Traumatic bilateral abducens nerve palsy is rare and is associated with intracranial, skull and cervical spine injuries. We report a case of bilateral abducens nerve palsy in a 40-month-old patient with a skull base fracture. The injury mechanism was associated with direct nerve injury caused by a right petrous bone fracture and indirect injury by frontal impact on the abducens nerve at the point of fixation to the petrous portion and Dorello's canal. The emergency physician should be aware of injuries and the mechanism of abducens nerve palsy in head trauma.

Relationship between Stiffness of Restorative Material and Stress Distribution for Notch-shaped Non-carious Cervical Lesions

  • Kim, Kwang-Hoon;Park, Jeong-Kil;Son, Kwon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.64-67
    • /
    • 2008
  • This study investigated the influence of composite resins with different elastic moduli and occlusal loading conditions on the stress distribution of restored notch-shaped non-carious cervical lesions (NCCL) using 3D finite element analysis. Two different materials, Tetric Flow and Z100, were used as representative flowable hybrid resins for the restoration of NCCL. A static point load of 500 N was applied at the buccal and palatal cusps. The ratios of stress reduction to energy dissipation were better in the compressive state than the tensile state regardless of the restorative material. The total dissipation ratios for Tetric Flow were 1.5% and 4.2% larger than those for Z100 under compression and tension, respectively. Therefore, tensile stress poses more of a risk for tooth fracture, and Tetric Flow is a more appropriate material for restoration.

Clinical and Radiological Outcomes of Anterior Cervical Interbody Fusion Using Hydroxyapatite Spacer

  • Kim, Sung-Chul;Kang, Sung-Won;Kim, Se-Hyuk;Cho, Ki-Hong;Kim, Sang-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.300-304
    • /
    • 2009
  • Objective : This is retrospective study of clinical and radiological outcomes of anterior cervical fusion using Bongros-$HA^{TM}$ (BioAlpha, Seongnam, Korea) which is a type of synthetic hydroxyapatite (HA) spacer to evaluate the efficacy in its clinical application and usefulness as a reliable alternative to autograft bone. Methods : Twenty-nine patients were enrolled in this study and 40 segments were involved. All patients were performed anterior cervical interbody fusion using HA spacer and plating system. Indications for surgery were radiculopathy caused by soft-disc herniation or spondylosis in 18 patients, spondylotic myelopathy in 1 patient, and spinal trauma in 10 patients. Cervical spine radiographs were obtained on postoperative 1day, 1week, and then at 1, 2, 6, and 12 months in all patients to evaluate intervertebral disc height, and the degrees of lordosis. Cervical computed tomography was done at postoperative 12 month in all patients to confirm the fusion status. The mean period of clinical follow-up was 17 months. Results : Complete interbody fusion was achieved in 100% of patients. Preoperative kyphotic deformities were corrected in all cases after surgery. Intervertebral disc height was well maintained during follow up period. There were no cases of graft extrusion, graft deterioration and graft fracture. Conclusion : HA spacer is very efficient in achieving cervical fusion, maintaining intervertebral disc height, and restoring lordosis. When combined with the placement of a cervical plate, immediate stability can be achieved and graft related complication can be prevented.

내부금속관 형태에 따른 도재전장금관의 파절강도와 도재색조에 관한 연구 (A STUDY ON FRACTURE STRENGTH AND COLOR BY THE DESIGN OF METAL COPING IN CERAMO METAL CROWN)

  • 이명호;전영찬
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.103-124
    • /
    • 1992
  • The purpose of this study was to investigate the effect on the fracture strength and color of ceramic by the design of the metal coping in ceramo metal crown. In this study, four types of ceramic crowns were made for fracture strength : standard ceramo metal crown, collariess ceramo metal crown, modified ceramo metal crown, and ceramic jacket crown. And three types of disk formed-specimens were made to compare the dentin shade owing to aluminous opaque powder and palladium alloy. Fracture strength was measured by universal testing machine(Instron Co. Ltd., U.S.A) and color was measured by color and color difference meter(Yasuda Seiki Seisakusho, Ltd., Japan). The results were as follows : 1. The fracture strength of ceramic was affected significantly by the design of metal coping in ceramo metal crown. The mean fracture strength(192.0 Kg) of standard ceramo metal crown was about 1.7 times higher than that(111.5 Kg) of collarless ceramo metal crown, and about 2.8 times higher than that(67.8 Kg) of ceramic jacket crown. 2. Modified ceramo metal crown that has metal band in the labio cervical had the lowest fracture strength. 3. Lightness, yellowness and redness of the dentin fired were decreased by the metal coping.

  • PDF

Radiographic Comparison of Four Anterior Fusion Methods in Two Level Cervical Disc Diseases : Autograft Plate Fixation versus Cage Plate Fixation versus Stand-Alone Cage Fusion versus Corpectomy and Plate Fixation

  • Kim, Min-Ki;Kim, Sung-Min;Jeon, Kwang-Mo;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권3호
    • /
    • pp.135-140
    • /
    • 2012
  • Objective : To evaluate radiographic results of anterior fusion methods in two-level cervical disc disease : tricortical autograft and plate fixation (ACDF-AP), cage and plate fixation (ACDF-CP), stand-alone cage (ACDF-CA), and corpectomy and plate fixation (ACCF). Methods: The numbers of patients were 70 with a minimum 6 month follow-up (ACDF-AP : 12, ACDF-CP : 27, ACDF-CA : 15, and ACCF : 16). Dynamic simple X-ray and computed tomography were evaluated preoperatively, postoperatively, 6 month, and at the final follow-up. The fusion and subsidence rates at the final were determined, and global cervical lordosis (GCL), cervical range of motion, fused segment angle (FSA), and fused segment height (FSH) were analyzed. Results: Nonunion was observed in 4 (25%) patients with ACDF-CA, 1 (8%) patient with ACDF-AP, 1 (4%) patient with ACDF-CP. The number of loss of FSH (%) more than 3 mm were 2 patients (16%) in ACDF-AP, 3 patients (11%) in ACDF-CP, 5 patients (33%) in ACDF-CA, and 3 patients (20%) in ACCF. The GCL was decreased with ACDF-CA and increased with others. The FSA was increased with ACDF-AP, ACDF-CP, and ACCF, but ACDF-CA was decreased. At the final follow-up, the FSH was slightly decreased in ACDF-CP, ACDF-AP, and ACCF, but ACDF-CA was more decreased. Graft related complication were minimal. Screw loosening, plate fracture, cage subsidence and migration were not identified. Conclusion: ACDF-CP demonstrated a higher fusion rate and less minimal FSH loss than the other fusions in two-level cervical disc disease. The ACDF-AP and ACCF methods had a better outcome than the ACDF-CA with respect to GCL, FSA, and FSH.

경추용 일체형 추간체 유합 보형재의 디자인 변화에 따른 생체역학적 효과 비교 연구 (Comparative Study on Biomechanical Behavior of Various Cervical Stand-Alone Cage Designs)

  • 박광민;정태곤;정승조;이성재
    • 한국정밀공학회지
    • /
    • 제33권11호
    • /
    • pp.943-950
    • /
    • 2016
  • The purpose of this study was to evaluate and compare by finite element analysis the biomechanical performance, in terms of cervical stand-alone cage screw insert angle (Type 3 - 5: 2 Screws) and screw arrangement (Type 6 and 7: 3 Screws / Type 8 and 9: 4 Screws), and the range of motion (ROM) of traditional anterior cervical discectomy of a fusion device (Type 1: Cage / Type 2: Cage + ACP). Our study suggests that the biomechanical behavior of a postoperative cervical spine could indeed be influenced by design features, such as screw angle and number of screws. In particular, ROM and the risk of subsidence were more sensitive during extension about type 5 (Insert Angle $20^{\circ}$). Our study also suggested that the number of screw asymmetries between up and down for type 6 and 7 could result in differences in the risk of screw fracture manifesting in different clinical aspects.

Delayed Brain Infarction due to Bilateral Vertebral Artery Occlusion Which Occurred 5 Days after Cervical Trauma

  • Jang, Donghwan;Kim, Choonghyo;Lee, Seung Jin;Kim, Jiha
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권2호
    • /
    • pp.141-145
    • /
    • 2014
  • Vertebral artery (VA) injuries usually accompany cervical trauma. Although these injuries are commonly asymptomatic, some result in vertebrobasilar infarction. The symptoms of VA occlusion have been reported to usually manifest within 24 hours after trauma. The symptoms of bilateral VA occlusions seem to be more severe and seem to occur with shorter latencies than those of unilateral occlusions. A 48-year-old man had a C3-4 fracture-dislocation with spinal cord compression that resulted from a traffic accident. After surgery, his initial quadriparesis gradually improved. However, he complained of sudden headache and dizziness on the 5th postoperative day. His motor weakness was abruptly aggravated. Radiologic evaluation revealed an infarction in the occipital lobe and cerebellum. Cerebral angiography revealed complete bilateral VA occlusion. We administered anticoagulation therapy. After 6 months, his weakness had only partially improved. This case demonstrates that delayed infarction due to bilateral VA occlusion can occur at latencies as long as 5 days. Thus, we recommend that patients with cervical traumas that may be accompanied by bilateral VA occlusion should be closely observed for longer than 5 days.

말티즈 견에서 Screw, Wire와 PMMA를 사용한 외상성 경추 골절의 안정화 (Stabilization using Screws, Wire, and PMMA for Traumatic Cervical Fracture in a Maltese Dog)

  • 김근영;김민경;박지훈;신정인;김준수;장윤설;이재훈
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.519-522
    • /
    • 2014
  • 2년령 2 kg 말티즈가 진행성 사지마비와 목의 통증으로 내원하였다. 개는 알 수 없는 외상 이후 지난 2주간 스테로이드로 처치되었으나 점진적으로 상태가 악화되었고, 사지마비 상태가 되었다. 내원 시 개는 보행이 불가능한 사지마비 상태를 보였다. 방사선 사진과 CT 결과, C2의 가로골절과, 환추관절과 C2-C3의 불완전 탈구가 발견되었다. 추가적으로, MRI 상에서 뇌수종이 관찰되었다. Screw, Wire 와 PMMA를 사용한 C1-C3의 안정화가 시행되었다. 수술 후 4주에 임상 증상이 개선되었고, 개는 수술 6주 후에 이전과 마찬가지로 보행이 가능하였다. 본 증례의 Screw, Wire 와 PMMA를 안정화로 경추 골절을 효과적으로 치료하였다.

외상성 경추 골절 후 발생한 Brown-Sequard 증후군 환자 1례 (A Case Report of Brown-Sequard Syndrome Caused by Traumatic Cervical Fracture)

  • 김슬기;김준현;박승혁;최준섭;조남근
    • Journal of Acupuncture Research
    • /
    • 제32권1호
    • /
    • pp.133-140
    • /
    • 2015
  • Objectives : The purpose of this study is to report a case of Brown-Sequard syndrome caused by traumatic cervical fracture, presenting pain in the right upper extremity and back of the left hand, motor weakness in the right side and diminished pain and temperature in the left side. Methods : A patient received Korean medical treatment(acupuncture, electroacupuncture, herbal medicine, cupping, moxibustion, Silver Spike point electrotherapy(SSP)) and rehabilitation treatment. We evaluated pain with the Numeric Rating Scale(NRS), motor grade with a Medical Research Council(MRC) scale, sensory function and Modified Barthel Index(MBI). Results : After treatment, the patient showed considerable improvement in NRS, motor & sensory function, and MBI. Conclusions : Korean medical and rehabilitation treatments could be effective for Brown-Sequard syndrome patients. More extensive studies should be carried out.