• Title/Summary/Keyword: Ceramic Adhesion

Search Result 203, Processing Time 0.032 seconds

Comparison between Shear and Tensile Adhesion Strength of Cement for Ceramic Tiles and an Experimental Evaluation on the Cutting Effect of Tile for Tensile Adhesion Strength (타일 시멘트 전단접착강도와 인장부착강도 비교 및 인발부착강도 타일커팅 영향에 관한 실험적 평가)

  • Lee, Sang-Hyun;Ki, Jun-Do;Cho, Hong-Bum;Kim, Young-Sun;Moon, Hyung-Jae;Jeon, Hyun-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.181-182
    • /
    • 2021
  • Selecting a proper tile cement for ceramic tile is important to secure tile construction quality. But there is some ambiguity in standards about evaluating adhesion test such as using KS L 1593 in Lab test but using KS L 1592 in site. So, this study aims to how to select proper tile cement for securing adhesion strength in site considering both tensile and shear adhesion strength of cement for ceramic tile. Also, when doing tensile adhesion test in site, there may be adhesion drop because of cutting tile with grinder. As a result, drop of adhesion strength is about 9% ans quality manager consider these factor and should select proper tile cement.

  • PDF

An Experimental Study on Bacterial Adhesion onto Activated Carbon and Ceramic (활성탄 및 세라믹 재질에의 세균 부착성에 대한 연구)

  • Kwon Sung-Hyun;Cho Dae-Chul;Rhee In-Hyoung
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1163-1170
    • /
    • 2005
  • The microbial adsorption characteristics of two different media for biological treatment were studied using attached diverse microbes onto activated carbon and ceramic. The results in the experiments of the characteristics of physical adhesion on two different media with addition of high and low concentrated substrate in the culture were observed that the efficient of adhesion onto F-400 activated carbon was higher over that of ceramic due to the surface area of media. The irradiation treatment by ultrasonication with 400 W power and 3 min retention time on the media without addition substrate conditions and subsequent mixing throughly the culture showed the highest efficiency of cell detachment on the media. Three different microbes, P. ovalis, A calcoaceticus, and B. subtillis were used for the study of the characteristics of microbial adhesion on the media. p ovalis showed the highest adhesion capability while B. subtillis showed the lowest capability adhesion onto media either addition of substrate in the culture. The mixed bacterial culture showed $10\%$ lower removal efficiency of DOC in the low concentrated substrate culture compared to the single pure culture. Whileas, it did not show significant difference between two cultures at high concentrated substrate. It was also observed same population density of microorganism by counting of microbes adhered to microbial media with an ultrasound treatment.

Adhesion improvement between metal and ceramic substrate by using ISG process (ISG법에 의한 금속과 세라믹기판과의 밀착력 향상)

  • 김동규;이홍로;추현식
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.6
    • /
    • pp.709-716
    • /
    • 1999
  • Ceramic is select for an alternative substrate material for high-speed circuits due to its low-thermal expansion. As, in this study, ceramic was prepared by ISG (interlayer sol-gel) process using metal salts and a metal alkoxide as the starting materials. Generally ceramic substrate is used electroless copper plating for the metallization. But it has been indicate weakely the adhesion strength between the substrate and copper layer. Therefore, this research, using the ISG process on the preparation of homogeneous and possible preparation at law temperature fabricated sol solution. Using of the dip coating method was coated for the purpose of giving the anchoring effect on the coating layer and enhancing the adhesion strength between the $Al_2$O$_3$ substrate and copper layer. This study examined primary the characteristic of the sol making condition and differential thermal analysis (DTA) X-ray diffraction (XRD) were mearsured to identify the crystal phase of heat treatment specimens. The morphology of the coated films were studied by scanning electron microscopy(SEM). As a resurt, XRD analysis was obtained patterns of $\alpha$-cordierite after heat-treatment about 2 hours at $1000^{\circ}C$. SEM analysis could have seen a large number of voids on coated film. The more contants of$ Al_2$$O_3$ Wt% was increased the more voids was advanced. Peel adhesion strength has a maximum in the contants of the TEOS:ANE of 1:0.7 mole%. In this case, adhesion strength has been measured 1150gf, peel adhesion strength were about 10 times more than uncoated of the ceramics film.

  • PDF

Surface Treatment of Dielectric Ceramic Resonator for High Frequency Devices (고주파용 유전체 세라믹 공진기의 표면처리)

  • Park, Hae-Duck;Kang, Sung-Goon
    • Korean Journal of Materials Research
    • /
    • v.11 no.11
    • /
    • pp.923-928
    • /
    • 2001
  • An electrolytic silver plating process has been successfully developed for terminated electrode parts of dielectric ceramic resonator. High adhesion strength and high Qu is obtained and blister occurance is minimized under plating condition with $HNO_3$750 $m\ell/\ell$ and HF $ 250m\ell/\ell$ solution at $25^{\circ}C$ for 20 minutes. Adhesion strength has the highest value, 3.2 kg/mm$^2$ at etching temperature of $25^{\circ}C$. Adhesion strength, Qu and blister occurance are monotonically increased with the thickness of electrodeposition layer. In case of electrodeposition of Ag, Qu value of 380 has obtained higher than in case of electrolytic Cu plating with Qu value of 325. Therefore, terminated electrode parts of dielectric ceramic resonator reducing dielectric loss can be obtained using prensent process.

  • PDF

Effect of Glass Additions on the Adhesion and Electrical Conductivity of Photoimageable Silver Paste

  • Lee, Eun-Heay;Heo, Yu-Jin;Kim, Hyo-Tae;Kim, Jong-Hee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.63-70
    • /
    • 2011
  • Anorthite forming glass frits in amounts up to 25 vol% of the silver powder were added to improve the adhesion between the conductor pattern formed by thick film photoimageable process and the low temperature co-fired ceramics (LTCC) substrate. The sheet resistance of the conductor pattern was raised from 0.13 ${\Omega}/{\square}$ to 2.25 ${\Omega}/{\square}$ as the volume percentage of glass frit increased up to 25 vol%. The adhesion strength was improved with this glass frit increase, but it decreased when the glass content exceeded 20 vol% which are possibly attributed to the liquid pool effect and the reduced fracture toughness in the interface between conductor and LTCC layer. The shrinkage of the width of the conductor pattern decreased with the addition of glass contents.

Fabrication and Adhesion Strength Evaluation of Glass Sealants for Ceramic to Ceramic Component Joining (세라믹-세라믹 컴포넌트 접합용 글라스 실란트의 제조 및 접합력 평가)

  • Heo, Yu Jin;Kim, Hyo Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.89-94
    • /
    • 2019
  • Glass base sealant is required as a ceramic-ceramic joining material between α-alumina insulation cap and β-alumina electrolyte tube in the development of NaS battery cell package for electrical energy storage system. The fabrication of glass frit by thermal quenching method, phase analysis, particle size analysis, coefficient of thermal expansion and surface roughness according to the glass compositions were analyzed for the fabrication of glass sealing paste for ceramic-ceramic joining. Also, a new evaluation method of the adhesion strength of glass sealant at the small area in ceramic-ceramic joining component was proposed using conventional Dage bond tester that was used to measure the adhesion of solder ball joint.

Development of Novel Composite Powder Friction Modifier for Improving Wheel-rail Adhesion in High-speed Train (고속열차 점착계수 향상을 위한 신규 복합재료 분말 마찰조절재 개발 및 점착력 특성 평가)

  • Oh, Min Chul;Ahn, Byungmin
    • Journal of Powder Materials
    • /
    • v.25 no.6
    • /
    • pp.501-506
    • /
    • 2018
  • With the recent remarkable improvements in the average speeds of contemporary trains, a necessity has arisen for the development of new friction modifiers to improve adhesion characteristics at the wheel-rail interface. The friction modifier must be designed to reduce slippage or sliding of the trains' wheels on the rails under conditions of rapid acceleration or braking without excessive rolling contact wear. In this study, a novel composite material consisting of metal, ceramic, and polymer is proposed as a friction modifier to improve adhesion between wheels and rails. A blend of Al-6Cu-0.5Mg metallic powder, $Al_2O_3$ ceramic powder, and Bakelite-based polymer in various weight-fractions is hot-pressed at $150^{\circ}C$ to form a bulk composite material. Variation in the adhesion coefficient is evaluated using a high-speed wheel-rail friction tester, with and without application of the composite friction modifier, under both dry and wet conditions. The effect of varying the weighting fractions of metal and ceramic friction powders is detailed in the paper.

Measurement of Adhesion Strength for Ceramic Sheet (세라믹 박판의 접착 강도 측정)

  • Huh, Y.H.;Kim, D.I.;Kim, D.J.;Lee, K.;Kim, D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1798-1802
    • /
    • 2007
  • Adhesion strength of single layer ceramic capacitor sheet was measured using a peel testing system developed in this study. The peel test specimens with various dimensions were prepared from the ceramic sheet cast on the PET film. In peel test, the sheet specimen was adhered on the glass jig floating on the liquid media, which was designed to minimize the friction, and the specimen was then pulled up by micro-actuator. During the separation of the sheet from the PET film, peel force was measured. To normalize the testing condition, 3 different widths of the specimen were selected: 5, 10 and 20 mm. was used Furthermore, testing speed effect was investigated in this study. From the resullts using various testing conditions, the standard method for the peel strength testing may be suggested. Based on the testing condition, effect of peel angle on the strength was experimentally examined. It was found that the adhesive strength for the ceramic sheet is nearly identical, irrespective of the specimen width ranged from 5 to 20 mm, while the adhesive strength was increased with increasing testing speed. Furthermore, the strength was shown to be dependent on the peel angle.

  • PDF

Adhesion Characteristic and Porosity Change of Alkali Silicate Impregnant of Concrete (Silicate계 콘크리트 함침제 도포에 따른 부착특성 및 공극변화)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu;Lim, Young-Chul
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.4
    • /
    • pp.276-282
    • /
    • 2010
  • There are the impregnating layer formation by surface protective materials or impregnants and the adhesion method by polymer, FRP sheet or steel plate in the surface protective method of concrete structure. The surface impregnation method by impregnants improves the durability of concrete structure by modifying the structure of the concrete surface and also have a merit that can be shortly applied in place without the decrease of concrete surface appearance and is easily applied again. This study is interested in manufacturing the concrete surface impregnants including lithium and potassium silicate for the repair of the exposed concrete and the color concrete requiring the advanced function in view of the concrete appearance. The durability and porosity properties was tested for the review of application. The result of this study show that the effective content of silicate ranges 5 to 20% and the separate application of the first impregnant and the second impregnant is effective for the optimum performance. The adhesion in tension is slightly increased but the reinforcement of concrete substrate is slight. So, the concrete impregnant of this study is more desirable for the improvement of durability rather than the reinforcement.

Bonding to zirconia with resin cements (지르코니아와 레진 시멘트의 결합)

  • Lim, Bum-Soon;Her, Soo-Bok
    • The Journal of the Korean dental association
    • /
    • v.49 no.5
    • /
    • pp.265-278
    • /
    • 2011
  • The introduction of zirconia-based materials to the dental field broadened the design and application limits of, all-ceramic restorations. Most ceramic restorations are adhesively luted to the prepared tooth, however, resin bonding to zirconia components is less reliable than those to other dental ceramic systems. It is important for high retention, prevention of microleakage, and increased fracture resistance, that bonding techniques be improved for zirconia systems. Strong resin bonding relies on micromechanical interlocking and adhesive chemical bonding to the ceramic surface, requiring surface roughening for mechanical bonding and surface activation for chemical adhesion. In many cases, high strength ceramic restorations do not require adhesive bonding to tooth structure and can be placed using conventional cements which rely only on micromechanical retention. However, resin bonding is desirable in some clinical situations. In addition, it is likely that strong chemical adhesion would lead to enhanced long-term fracture and fatigue resistance in the oral environment.