• Title/Summary/Keyword: Centrifugal tests

Search Result 105, Processing Time 0.028 seconds

Influence of Materials and Embedded Depth of Isolation Barrier on Ground Vibration - With Point Loaded Centrifugal Tests - (진동 차단벽재료 및 타설심도가 방진효과에 미치는 영향 - 점가진 원심모형실험을 중심으로 -)

  • 이강일;김태훈
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.41-49
    • /
    • 2004
  • In general, open trenches or in-filled trenches have been used to isolate transmitting of vibration. Recently alternative methods, in which various materials are used for wall barriers have been proposed and performed in several sites. Although the effects of these methods are verified, resonable and qualitative evaluation methods have not yet been conducted. It may be because many factors, such as the characteristics of vibration sources, ground condition, and parameters of wall barrier are coupled complicatedly. In this study, a series of centrifugal modelings were conducted in order to examine the evaluation method of a vibration wall barrier when point load transmits to the surface. The experiments were performed with different stiffness of wall barriers and different depths of installations. Using the results obtained from tests, effects of those variables on the efficiency of vibration barrier were analyzed. Through this investigation we observed vibration transmission of under ground, and verified the applicability of ball dropping system which was developed in this study.

Analysis of the Structural Behaviors of Tunnel Linings in Joomunjin Standard Sand by Centrifugal Model Tests (원심모형실험에 의한 사질토 지반내 터널 복공의 역학적 거동에 관한 연구)

  • 김택곤;김영근;박중배;이희근
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.161-168
    • /
    • 1999
  • A series of centrifuge model tests were performed in order to investigate the behaviors of various tunnel linings. A 1/100-scaled aluminum and hydrostone horseshoe tunnel linings with a radius km, height km were buried in a depth of C/D=3 with dry Joomunjin standard sand, the relative density of which was 86%. Bending moments and thrusts along the tunnel circumference were measured by 12 strain gages. Earth pressures in soil and on lining were estimated by pressure transducers, ground surface settlements at center and edges by using LVDTs. Average Ko(coefficient of earth pressure at rest) was 0.39 for the model sand. The structural behaviors of lining depended on its damaged conditions. But, as a rule, on the crown, the tensile circumferential strain of lining occurred at the inner surface, and the compressive at the outer surface, then positive bending moment was created at the crown. The circumferential strain of the inner surface on the springline was tensile, and the outer compressive, so negative bending moment was measured at the springline. For hydrostone linings, cracks initiated at the inner surface on the crown, and the outer on the springline over average 40g.

  • PDF

Development of Centrifugal Compressors in an 1.2MW Industrial Gas Turbine(I)-Aerodynamic Design and Analysis- (1.2MW급 산업용 가스터빈 원심압축기 개발(1)- 공력설계해석 -)

  • Jo, Gyu-Sik;Lee, Heon-Seok;Son, Jeong-Rak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.8
    • /
    • pp.2707-2720
    • /
    • 1996
  • The aerodynamic design of the two-stages of centrifugal compressors in an 1.2MW industrial gas turbine is completed with the application of numerical analyses. The final shape of an intake, the axial guide vanes and a return channel is determined using several interactions between design and two-dimensional turbulent flow analysis, focused on the minimum loss of internal flows. The one-dimensional turbulent flow analysis, focused on the minimum loss of internal flows. The one-dimensional design and prediction of aerodynamic performances for the compressors are performed by two different methods; one is a method with conventional loss models, and the other a method with the two-zone model. The combination methods of the Betzier curves generate three-dimensional geometric shapes of impeller blades which are to be checked with a careful change of aerodynamic blade loadings. The impeller design is finally completed by the applications of three-dimensional compressible turbulent flow solvers, and the effect of minor change of design of the second-stage channel diffuser is also studied. All the aerodynamic design results are soon to the verified by component performance tests of prototype centrifugal compressors.

Study on the Performance Characteristics of Centrifugal Pump with Drag-reducing Surfactant Additives

  • Wang, Lu;Li, Feng-Chen;Dong, Yong;Cai, Wei-Hua;Su, Wen-Tao
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.223-228
    • /
    • 2011
  • The performance characteristics of centrifugal pump were measured experimentally when running with tap water and drag-reducing surfactant (Octadecyl dimethyl amine oxide (OB-8)) solutions. Tests have been performed on five cases of surfactant solutions with different concentrations (0ppm (tap water), 200ppm, 500ppm, 900ppm and 1500ppm) and four different rotating speeds of pump (1500rpm, 2000rpm, 2500rpm and 2900rpm). Compared with tap water case, the experimental results show that the total pump heads for surfactant solution cases are higher. And the pump efficiency with surfactant solutions also increases, but the shaft power for surfactant solutions cases decreases compared to t hat for tap water. There exists an optimal temperature for surfactant solutions, which maximizes the pump efficiency.

Waterhammer Caused by Startup and Stoppage of a Centrifugal Pump (원심펌프의 시동 및 정지에 따른 수격현상)

  • Kim, Kyung-Yup;Kim, Joum-Bea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.51-57
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity As the pressure waves are propagating between the pumping station and the distributing reservoir, the pressure inside the pipe drops to the liquid vapor pressure with the pipeline profile, at which time a vapor cavity forms, and finally the column separation occurs. If the pressure in the pipe is less than the atmospheric pressure, the pipe can be collapsed and destroyed after the water columns separated by the vapor cavity rejoin. During the reverse flow, the pressure is so abnormally increased at the pumping station that the accident of flooding may happen due to the failure of system. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations, in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

Improvement in Efficiency and Operating Range of Centrifugal Blower Stage for Sewage Aeration Blower

  • Hiradate, Kiyotaka;Kanno, Toshio;Nishida, Hideo;Shinkawa, Yasushi;Joukou, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.379-385
    • /
    • 2010
  • We developed a high-efficiency, wide-operating-range centrifugal blower stage to meet the demand for reduced total energy-consumption in sewage treatment plants. We improved the efficiency of the two-dimensional impeller using a shape optimization tool and one-dimensional performance prediction tool. A limit of the throat deceleration ratio was set to maintain the stall-margin of the impeller. The low solidity vaned diffuser and return channel were designed using a sensitivity analysis with orthogonal arrays and three-dimensional steady flow simulations. The low solidity diffuser was designed in order to improve the performance in the low-flow-rate region. The return channel was designed so that the total pressure loss in the return channel was minimized. Model tests of both the conventional and optimized blower stages were carried out, and the efficiency and operating range of both stages were compared. The optimized blower stage improved in stage efficiency by 3% and in operating range by 5% compared with the conventional blower stage.

Development of Cast Rolls by Horizontal Spin Casting Method (수평원심주조법에 의한 주조롤 개발)

  • Suh, Y.C.;Park, J.W.;Kim, S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.04a
    • /
    • pp.111-114
    • /
    • 2009
  • Production of rolled steel has been growing partly supported by the advancement of rolls and rolling mills. Aiming at the further improvement in roll performance, various new techniques such as centrifugal casting, double poured casting cast steel, special build-up making, etc. have been introduced in the field of roll manufacture in these several years. The present paper describes the development of horizontal cast rolls(sleeve and indefinite chilled roll) made by Hyundai Steel and the results of mill tests. The developed roils are contributing the improvement of final products.

  • PDF

Waterhammer in Transmission Pumping Station with Ball Valve (볼밸브를 사용한 송수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Kim, Joum-Bea
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1697-1702
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure. the hydraulic transients occur as a result of the sudden change in velocity. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations. in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

  • PDF

Application of Gurney Flaps on a Centrifugal Fan Impeller

  • Dundi, Thomas Manoj Kumar;Sitaram, Nekkanti;Suresh, Munivenkatareddy
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.2
    • /
    • pp.65-71
    • /
    • 2012
  • The objective of the present investigation is to explore the possibility of improving the performance of a centrifugal fan at low Reynolds numbers using a simple passive means, namely Gurney flap (GF). GFs of 1/$8^{th}$ inch brass angle (3.175 mm) corresponding to 15.9% of blade exit height or 5.1% of blade spacing at the impeller tip are attached to the impeller blade tip on the pressure surface. Performance tests are carried out on the centrifugal fan with vaneless diffuser at five Reynolds numbers (viz., 0.30, 0.41, 0.55, 0.69, $0.82{\times}10^5$, i.e., at five speeds respectively at 1,100, 1,500, 2,000, 2,500 and 3,000 rpm) without and with GF. Static pressures on the vaneless diffuser hub and shroud are also measured for each speed at four flow coefficients [${\phi}$=0.23 (below design flow coefficient), ${\phi}$=0.34 (design flow coefficient), ${\phi}$=0.45 (above design flow coefficient) and ${\phi}$=0.60 (above design flow coefficient)] with and without GF. From the performance curves it is found that the performance of the fan improves considerably with GFs at lower Reynolds numbers and improves marginally at higher Reynolds number. Similar improvements are observed for the static pressures on the diffuser hub and shroud. The effect of Reynolds number on the performance and static pressures is considerable. However the effect is reduced with GFs.

Spray Pattern Analysis for a Centrifugal Fertilizer Distributor with Two Shutter Holes (두 개의 셔터 구멍이 적용된 원심식 비료 살포기의 살포패턴 분석)

  • Hwang, Seok-Joon;Park, Jeong-Hyeon;Lee, Ju-Yeon;Kim, Ki-Duck;Shin, Beom-Soo;Nam, Ju-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.8-19
    • /
    • 2019
  • In this study, the spray pattern of a centrifugal fertilizer distributor with two shutter holes was analyzed and an effective driving width that satisfies proper spray uniformity was derived. The centrifugal fertilizer distributor was mounted on a tractor with a rated power of 23.7 kW and static and dynamic spray pattern tests were performed according to the standard procedure proposed by the American Society of Agricultural and Biological Engineers Standard ASAE S341.5. The height of the fertilizer distributor was 80 cm from the ground and the PTO (power take-off) shaft speed of the tractor was fixed at 540 rpm. The fertilizer scattered in space was collected using 275 evenly spaced collectors at shutter opening ratios of 25%, 50%, 75%, and 100%. The spray pattern was analyzed via the amount of sprayed fertilizer at each collector location and the coefficient of variation was used as an indicator of spray uniformity. Using the analyzed spray pattern, the effective driving width that satisfied less than 15% of the coefficient of variation was derived for different tractor driving patterns (race track mode, back and forth mode). From the results, spray uniformity increased as the shutter opening ratio decreased. The largest effective driving width was 8 m at a shutter opening ratio of 25% for both driving patterns.