• 제목/요약/키워드: Centrifugal Chiller

검색결과 36건 처리시간 0.031초

R134a 터보 냉동기용 2단 원심 압축기의 수치해석 기법과 내부유동 특성 (Numerical Analysis Techniques and Flow Characteristics of Two-Stage Centrifugal Compressor for R134a Turbo-Chiller)

  • 박한영;오현택;신유환;이윤표;김광호;정진택
    • 한국유체기계학회 논문집
    • /
    • 제10권4호
    • /
    • pp.29-38
    • /
    • 2007
  • In this study, flow structure in a two-stage centrifugal compressor for a turbo-chiller with the refrigerant, R134a, was numerically investigated at the design point of the compressor using a commercial code. Flow characteristics in the passages of impeller, diffuser and return channel were analyzed in detail including velocity vector, secondary flow, Mach number and pressure contours in blade spanwise and meridional plane for each stage. The estimation on the one-dimensional output from the preliminary design and three-dimensional shape of the impeller blade and the meridional shape of the return channel were performed through the flow analysis, while some numerical schemes and techniques including Multiple Frames of Reference technique, real gas property data and inlet boundary condition changes, which were used in CFD, were compared with their features. The results will be used as reference data for a new design of 3-D impeller shape to improve R134a compressor performance.

가변속 터보냉동기의 기동특성에 관한 연구 (A Study on the Starting Characteristic of Variable Speed Centrifugal Chiller)

  • 김희선;윤홍민;나승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.512-513
    • /
    • 2012
  • The electric motor is essential to drive turbo machinery. In order to overcome the speed limitations of general motors, the inverter is used to perform high speed to tens of rpm. The high speed drives are widely used in many applications such as turbo blower, turbo centrifugal compressors, and pump using air bearing technique. Starting of high speed motor can cause step out, stall, oscillation of motor because the phase inductance is much smaller than that of ordinary motor. This paper studied on the starting characteristic of variable speed centrifugal chiller considering high speed motor characteristics. Finally, the superiority of the inverter is verified by experimental results.

  • PDF

뉴로 퍼지를 이용한 냉동기 성능 진단 기법 (Neuro-Fuzzy Diagnostic Technique for Performance Evaluation of a Chiller)

  • 신영기;장영수;김영일
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.553-560
    • /
    • 2003
  • On-site diagnosis of chiller performance is an essential step fur energy saving business. The main purpose of the on-site diagnosis is to predict the COP of a target chiller. Many models based on thermodynamics background have been proposed for this purpose. However, they have to be modified from chiller to chiller and require deep insight into thermodynamics that most of field engineers are often lacking in. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). Quality of the training data for ANFIS, sampled over June through September, is assessed by checking COP prediction errors. The architecture of the ANFIS, its error bounds, and collection of training data are described in detail.

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

냉동기 성능 진단을 위한 적응형 뉴로퍼지(ANFIS) 모델 개발 (Prediction of Vapor-Compressed Chiller Performance Using ANFIS Model)

  • 신영기;장영수;김영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.89-95
    • /
    • 2001
  • On-site diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the on-site diagnosis is to predict the COP of a target chiller. Many models based on thermodynamics background have been proposed for the purpose. However, they have to be modified from chiller to chiller and require deep insight into thermodynamics that most of field engineers are often lacking in. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). Quality of the training data for ANFIS, sampled over June through September, is assessed by checking COP prediction errors. The architecture of the ANFIS, its error bounds, and collection of training data are described in detail.

  • PDF

디퓨저 베인 설치각 변화에 따른 R134a 원심압축기 성능 분석 (Performance Analysis of a Centrifugal Compressor for HFC-134a with Variation of Diffuser Vane Angle)

  • 박한영;신유환;이윤표;김광호;정진택;조용훈;김종성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2823-2828
    • /
    • 2007
  • Numerical simulation on the two-stage centrifugal compressor with Low Solidity Vaned Diffuser LSVD) for HFC-134a Turbo-chiller was performed using a commercial code. The comparative study with experimental results from other compressor was also investigated to testify the simulation schemes. The numerical analysis was separately simulated for each stage of the compressor and the effect of impeller-diffuser flow interaction was considered. Setting angle of the diffuser vane changed in the range of 15 deg. and the effects on its variation were discussed in detail including the flow analysis in the passage of the compressor. The vane setting angle obtained from the preliminary design was slightly adjusted to the optimal value by the performance enhancement in terms of pressure recovery and flow characteristics.

  • PDF

R12 냉매를 이용한 냉동압축기 임펠러 유동해석 (Numerical analysis on the impeller of chiller compressor using refrigerant R12)

  • 음학진;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.696-701
    • /
    • 2001
  • The performance and the internal flow of the impeller of the centrifugal chiller compressor with refrigerant R12 as working fluid were studied numerically, using CFD code, CFX-Tascflow, which is commercially available. In this numerical study, the thermodynamic and transport properties of the refrigerant gas were generated by the property program of NIST and linked with main program to extend the capability of the code to refrigerant gases. Numerical study was applied to several mass flow rates near the design mass flow rate at constant rotating speed. Overall performance and flow characteristics of the impeller at impeller exit were investigated. The results were physically reasonable and showed good agreement with experimental measurement at the design flow rate.

  • PDF

터보 냉동기의 소음원 파악 및 저소음화에 대한 연구 (A Study on the identification of the noise source and noise reduction method of turbo chiller)

  • 전완호;이준근;정필중;염창훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.125-131
    • /
    • 2000
  • The turbo chiller uses centrifugal compressor, which operates at about 14500 rpm. Due to the high rpm of the impeller, the noise of chiller makes one of the serious problems. The possibility of the sound reduction by using absorbing material is studied in this paper. The generated sound propagates through the duct and then radiates to the outer field. So, the use of sound absorption material inside the duct is one of the effective methods. To study the effect of location of the material, we use Boundary Element Method to analyze the sound field inside the duct system. Numerical study shows the highest sound pressure region is near the elbow of curved duct. From the analysis, it is also shown that the elbow duct is the main radiator of noise and sound absorption treatment of this duct results noise reduction of the highest noise level at BPF and high frequency region.

  • PDF

대체냉매용 원심압축기의 설계 및 성능시험 (The Design and Performance Test of a Centrifugal Compressor for HFC-134a)

  • 신정관;김경훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.250-257
    • /
    • 2002
  • A centrifugal compressor for HFC-l34a has been newly designed and developed. Flow analysis using commertial programs was used to evaluate performance and internal flow of the impeller, inlet guide vane and diffuser etc. and design software was developed. The compressor for HFC-l34a was also investigated experimentally to check compression performance. The calculated data coincide the test results of compressor. The data obtained in the present study are useful for design of HFC-l34a centrifugal compressors.

  • PDF