• 제목/요약/키워드: Centrifugal

검색결과 1,669건 처리시간 0.025초

Rotational Behavior Tests of Smart Blades

  • Ogawa, Akinori;Hashimoto, Ryosaku;Matsuda, Yukio;Sofue, Yasushi;Hojo, Masahito
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.867-869
    • /
    • 2004
  • A smart blade conception has been proposed by the authors. With stretching-twisting coupling effect, the blade is twisted by centrifugal load or ambient temperature change. In this paper, the blades, made by three kinds of anti-symmetric laminates, are investigated by rotational tests. The results show the angle of smart blade tips increases in proportion to the 2nd power of a rotating speed and is well in agreement with the numerical results by FEM.

  • PDF

천음속 원심압축기의 공력설계 및 수치해석 (Aerodynamic Design and Numerical Analysis on a Transonic Centrifugal Compressor)

  • 최재호
    • 한국추진공학회지
    • /
    • 제12권4호
    • /
    • pp.56-62
    • /
    • 2008
  • 가스터빈에 적용되는 천음속 원심압축기에 대한 공력설계 및 수치해석을 수행하였다. 평균유선법과 준삼차원 해석을 기반으로 공력설계를 수행하고, 레이놀즈 평균 나비어-스톡스 해석을 통해 압축기 내부 유동장을 해석하였다. 천음속 압축기에서 정압계수, 스월 파라미터 및 블레이드 공력하중 등 주요 공력파라미터들에 대한 분석과 임펠러와 디퓨저 내부 유동장에 대한 고찰이 이루어졌다.

추출 회수에 따른 홍삼 extract의 성분 조성에 관한 연구 (Effect of Extraction on Chemical Composition of Rcd Ginseng Extract)

  • 최강주;김만욱;성현순;홍순근
    • Journal of Ginseng Research
    • /
    • 제4권1호
    • /
    • pp.88-95
    • /
    • 1980
  • Red ginseng was extracted with water and analyzed for yield, saponin, pectin and other chemical composition. It was found that: (1) The total solid content in extract after 6 times of extraction was 46.8%,: including 13.6% of centrifugal residue; (2) 83.7% of total extractable solids and 86% total saponin was extracted after the initial three runs of extraction. (3) No significant changes were observed in HPLC pattern of extracted saponins over a range of extractions; (4) The ratio of centrifugal residue to total solids increased as the number of extractions increased; (5) The ratios of fat, protein, reducing sugar and pectin contents decreased with repeating extraction while those of crude fiber, total sugar and 35% alcohol insoluble residue increased when they were compared with total solids.

  • PDF

원심모형실험을 이용한 터널 측방배수관에 퇴적되는 침전물 저감방안 연구 (A study on the Reduction Scheme of Sediments Deposited on a Lateral Drain Pipe in Tunnel using Centrifugal Tests)

  • 김태영;김유석;박종관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1380-1384
    • /
    • 2006
  • Sediments deposited on lateral drain pipes in a tunnel make lateral porous pipes clogged. Since the safety of the tunnel can be affected by this phenomenon, it requires a regular maintenance of the lateral drain pipes. In this study, a series of centrifugal tests were conducted in order to find out the method which can reduce the clogging effect considerably. Four different types of tunnel drain configurations were selected in the experiments. By analysis of sediments for each configuration, the optimum drain configuration that can minimize sedimentation of cement constituents was investigated. As a results, the existing drain configuration which uses filter concrete appear to produce much sediments. In contrast, the new drain configuration appears to be able to reduce sedimentation ratio up to almost 50% comparing with the existing one. From these observations, it may be concluded that the new drain configuration, in which the lateral porous pipes of a tunnel are surrounded by gravel layer and non-woven geotextile, has high efficiency in maintenance.

  • PDF

디퓨저 베인각의 변화에 따른 압축기 성능 특성 (Compressor Performance with Variation of Diffuser Vane Inlet Angle)

  • 배명형;신유환;김광호;김진형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.55-60
    • /
    • 1999
  • A centrifugal compressor was tested with three different diffusers with plate vanes. The vane inlet angle was varied from 15 to 30 dog. The higher static pressure rises are obtained with lower vane stagger angle. In the stable region the static pressure field in vaneless space is very sensitive to flow rate. The impeller has a stabilizing effect over the whole stable operating range. The diffuser has a stabilizing effect at high flow rate but is destabilizing at low flow rate.

  • PDF

Optimization of Blade Profile of a Plenum Fan

  • Wu, Lin;Dou, Hua-Shu;Wei, Yikun;Chen, Yongning;Cao, Wenbin;Ying, Cunlie
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.95-106
    • /
    • 2016
  • A method of optimization design for the blade profile of a centrifugal impeller by controlling velocity distribution is presented, and a plenum fan is successfully designed. This method is based on the inner flow calculation inside the centrifugal impeller, and is related to the distribution of relative velocity. The results show that after optimization, the boundary layer separation on the suction surface has been inhibited and the stability of plenum fan is improved. The flow at the impeller outlet is also studied, and the jet-wake pattern at the impeller outlet is improved obviously by optimization. The calculation result shows that the static pressure and static pressure efficiency can be increased by 15.4% and 21.4% respectively.

2차원 원심 압축기의 깃 없는 디퓨저에서의 불안정 유동 (Unstable Flow in a Vaneless Diffuser of 2-Dimensional Centrifugal Compressor)

  • 강경준;신유환;김광호;이윤표
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.5-11
    • /
    • 2011
  • This study investigated on details of flow characteristics in a vaneless diffuser of a compressor with 2-dimensional impeller at various flow rates. Experiment for a low speed compressor model in a water reservoir was performed to analyze the flow field in the vaneless diffuser and volute casing, which was done by PIV measurement. It was also focused on the periodic flow patterns occurring at low flow rate near unstable operating region of the compressor. At low flow rate condition, the flow visualization clearly shows that the flow energy from impeller is highly accumulated at the compressor exit by the blockage effect of a flow damper and consequently the reverse flow occurs in the diffuser.

A Second Order Exact Scaling Method for Turbomachinery Performance Prediction

  • Pelz, Peter Fanz;Stonjek, Stefan Sebastian
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권4호
    • /
    • pp.177-187
    • /
    • 2013
  • A scaling method valid for most turbomachines based on first principles is derived. It accounts for axial and centrifugal turbomachines with respect to relative gap width/tip clearance, relative roughness, Reynolds number and/or Mach number for design and off-design operation as well. The scaling method has been successfully validated by a variety of experimental data obtained at TU Darmstadt. The physically based, hence reliable and universal method is compared with previous, empirical scaling methods.

대체에너지 사용시 공업용수 순환 개선을 위한 연구 (Study of industrial water calculation improvement by use Alternative Energy)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권4호
    • /
    • pp.307-310
    • /
    • 2011
  • 이 논문은 1년에 몇 일 혹은 몇 시간 동안 만 최대 에너지가 공급된다. 그러므로 일반적인 경우에는 대부분 최대 에너지의 50%나 이보다 적은 양의 에너지를 얻게 된다. 이런 작은량의 에너지가 공급되는 Alternative Energy system (P. Voltac System)하에서 용수공급을 위해 기존의 Centrifugal pump를 사용 할 때와 Screw type pump를 사용할 때 공급된 용수량을 비교하였다. 연구 결과 Screw type pump 사용 시 alternative Energy system의 높이에 상관없이 단지 Screw type pump의 speed에 영향을 받으며 낮은 Energy 하 에서도 비교적 높은 효율을 낸다는 것을 실험적으로 비교 검토 하였다.

원심모형실험에 의한 지하굴착 붕괴양상에 관한 계측 및 해석 (Monitoring & Analysis on Excavation Failure Modes by Centrifugal Model Experiment)

  • 허열;안광국;이처근
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.135-142
    • /
    • 1998
  • This paper is to investigate the failure surface and modes in a soil mass by a excavation of the model ground. To study the failure surface for the excavated slope, centrifugal model tests were performed by changing the angle of the excavated slope(50, 75, $90^{\circ}$) and the ground condition($D_r$=60, 90%, dry and submerged ground). Excavation was simulated during the centrifuge tests by operating a valve that allowed the zinc chloride solvent to drain from the excavation. Results of model tests were compared with those obtained with theoretical solutions using limit equilibrium analysis method. The results of model tests show that, there is a failure to create a straight line in the low angle of excavated surface and a create a circle as the angle increases. Also, as the angle of excavated surface is increasing, the angle of the failure surface increases. The failure length in the submerged ground increases approximately 1.10~1.34 times more than that of the dry ground.

  • PDF