• Title/Summary/Keyword: Centrifugal

Search Result 1,669, Processing Time 0.028 seconds

Rotational Behavior Tests of Smart Blades

  • Ogawa, Akinori;Hashimoto, Ryosaku;Matsuda, Yukio;Sofue, Yasushi;Hojo, Masahito
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.867-869
    • /
    • 2004
  • A smart blade conception has been proposed by the authors. With stretching-twisting coupling effect, the blade is twisted by centrifugal load or ambient temperature change. In this paper, the blades, made by three kinds of anti-symmetric laminates, are investigated by rotational tests. The results show the angle of smart blade tips increases in proportion to the 2nd power of a rotating speed and is well in agreement with the numerical results by FEM.

  • PDF

Aerodynamic Design and Numerical Analysis on a Transonic Centrifugal Compressor (천음속 원심압축기의 공력설계 및 수치해석)

  • Choi, Jae-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.4
    • /
    • pp.56-62
    • /
    • 2008
  • This study presents the aerodynamic design and numerical analysis results on a transonic centrifugal compressor which is used for gas turbine systems. Mean-line analysis and quasi-3D analysis are used for the aerodynamic design, and Reynolds-averaged Navier-Stokes analysis is applied to flow analysis of the compressor. The aerodynamic parameters for a transonic compressor, such as pressure coefficient, swirl parameter, blade loading, are discussed, and flow characteristics in the impeller and diffuser are discussed.

Effect of Extraction on Chemical Composition of Rcd Ginseng Extract (추출 회수에 따른 홍삼 extract의 성분 조성에 관한 연구)

  • 최강주;김만욱;성현순;홍순근
    • Journal of Ginseng Research
    • /
    • v.4 no.1
    • /
    • pp.88-95
    • /
    • 1980
  • Red ginseng was extracted with water and analyzed for yield, saponin, pectin and other chemical composition. It was found that: (1) The total solid content in extract after 6 times of extraction was 46.8%,: including 13.6% of centrifugal residue; (2) 83.7% of total extractable solids and 86% total saponin was extracted after the initial three runs of extraction. (3) No significant changes were observed in HPLC pattern of extracted saponins over a range of extractions; (4) The ratio of centrifugal residue to total solids increased as the number of extractions increased; (5) The ratios of fat, protein, reducing sugar and pectin contents decreased with repeating extraction while those of crude fiber, total sugar and 35% alcohol insoluble residue increased when they were compared with total solids.

  • PDF

A study on the Reduction Scheme of Sediments Deposited on a Lateral Drain Pipe in Tunnel using Centrifugal Tests (원심모형실험을 이용한 터널 측방배수관에 퇴적되는 침전물 저감방안 연구)

  • Kim, Tae-Young;Kim, You-Seok;Park, Jong-Kwan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1380-1384
    • /
    • 2006
  • Sediments deposited on lateral drain pipes in a tunnel make lateral porous pipes clogged. Since the safety of the tunnel can be affected by this phenomenon, it requires a regular maintenance of the lateral drain pipes. In this study, a series of centrifugal tests were conducted in order to find out the method which can reduce the clogging effect considerably. Four different types of tunnel drain configurations were selected in the experiments. By analysis of sediments for each configuration, the optimum drain configuration that can minimize sedimentation of cement constituents was investigated. As a results, the existing drain configuration which uses filter concrete appear to produce much sediments. In contrast, the new drain configuration appears to be able to reduce sedimentation ratio up to almost 50% comparing with the existing one. From these observations, it may be concluded that the new drain configuration, in which the lateral porous pipes of a tunnel are surrounded by gravel layer and non-woven geotextile, has high efficiency in maintenance.

  • PDF

Compressor Performance with Variation of Diffuser Vane Inlet Angle (디퓨저 베인각의 변화에 따른 압축기 성능 특성)

  • Bae, M. H.;Shin, Y. H.;Kim, K. H.;Kim, J. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.55-60
    • /
    • 1999
  • A centrifugal compressor was tested with three different diffusers with plate vanes. The vane inlet angle was varied from 15 to 30 dog. The higher static pressure rises are obtained with lower vane stagger angle. In the stable region the static pressure field in vaneless space is very sensitive to flow rate. The impeller has a stabilizing effect over the whole stable operating range. The diffuser has a stabilizing effect at high flow rate but is destabilizing at low flow rate.

  • PDF

Optimization of Blade Profile of a Plenum Fan

  • Wu, Lin;Dou, Hua-Shu;Wei, Yikun;Chen, Yongning;Cao, Wenbin;Ying, Cunlie
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.95-106
    • /
    • 2016
  • A method of optimization design for the blade profile of a centrifugal impeller by controlling velocity distribution is presented, and a plenum fan is successfully designed. This method is based on the inner flow calculation inside the centrifugal impeller, and is related to the distribution of relative velocity. The results show that after optimization, the boundary layer separation on the suction surface has been inhibited and the stability of plenum fan is improved. The flow at the impeller outlet is also studied, and the jet-wake pattern at the impeller outlet is improved obviously by optimization. The calculation result shows that the static pressure and static pressure efficiency can be increased by 15.4% and 21.4% respectively.

Unstable Flow in a Vaneless Diffuser of 2-Dimensional Centrifugal Compressor (2차원 원심 압축기의 깃 없는 디퓨저에서의 불안정 유동)

  • Kang, Kyung-Jun;Shin, You-Hwan;Kim, Kwang-Ho;Lee, Yoon-Pyo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • This study investigated on details of flow characteristics in a vaneless diffuser of a compressor with 2-dimensional impeller at various flow rates. Experiment for a low speed compressor model in a water reservoir was performed to analyze the flow field in the vaneless diffuser and volute casing, which was done by PIV measurement. It was also focused on the periodic flow patterns occurring at low flow rate near unstable operating region of the compressor. At low flow rate condition, the flow visualization clearly shows that the flow energy from impeller is highly accumulated at the compressor exit by the blockage effect of a flow damper and consequently the reverse flow occurs in the diffuser.

A Second Order Exact Scaling Method for Turbomachinery Performance Prediction

  • Pelz, Peter Fanz;Stonjek, Stefan Sebastian
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.4
    • /
    • pp.177-187
    • /
    • 2013
  • A scaling method valid for most turbomachines based on first principles is derived. It accounts for axial and centrifugal turbomachines with respect to relative gap width/tip clearance, relative roughness, Reynolds number and/or Mach number for design and off-design operation as well. The scaling method has been successfully validated by a variety of experimental data obtained at TU Darmstadt. The physically based, hence reliable and universal method is compared with previous, empirical scaling methods.

Study of industrial water calculation improvement by use Alternative Energy (대체에너지 사용시 공업용수 순환 개선을 위한 연구)

  • Choi, Do-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.307-310
    • /
    • 2011
  • In this paper we use general centrifugal pump instead of screw pump in alternative Energy system. This alternative Energy system with screw pump compared the volume flour of water pumping and efficiency. Screw pump is designed that it rotated without a toque in another Shaft. Futhermore it have noise and abrasion, The pump used in high pressure with fast rotate.

Monitoring & Analysis on Excavation Failure Modes by Centrifugal Model Experiment (원심모형실험에 의한 지하굴착 붕괴양상에 관한 계측 및 해석)

  • Heo, Y.;Ahn, K.K.;Lee, C.K.
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.135-142
    • /
    • 1998
  • This paper is to investigate the failure surface and modes in a soil mass by a excavation of the model ground. To study the failure surface for the excavated slope, centrifugal model tests were performed by changing the angle of the excavated slope(50, 75, $90^{\circ}$) and the ground condition($D_r$=60, 90%, dry and submerged ground). Excavation was simulated during the centrifuge tests by operating a valve that allowed the zinc chloride solvent to drain from the excavation. Results of model tests were compared with those obtained with theoretical solutions using limit equilibrium analysis method. The results of model tests show that, there is a failure to create a straight line in the low angle of excavated surface and a create a circle as the angle increases. Also, as the angle of excavated surface is increasing, the angle of the failure surface increases. The failure length in the submerged ground increases approximately 1.10~1.34 times more than that of the dry ground.

  • PDF