• Title/Summary/Keyword: Centrifugal

Search Result 1,669, Processing Time 0.02 seconds

A Study of Performance Analysis for a Double-Suction Centrifugal Pump (양쪽 흡입 원심펌프의 성능해석에 대한 연구)

  • Chung, Kyung-Nam;Park, Pyun-Goo;Cho, Hyun-Jun;Lee, Sang-Gu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.7-15
    • /
    • 2001
  • Flow analysis was carried out for a double-suction centrifugal pump. Impeller-only models and a full pump model were used to simulate the velocity field and the pressure field of the pump. Heads and efficiencies were calculated with flow rates in order to obtain general performance of the pump. The calculation results were compared to the experimental data, and satisfactory results were obtained. Thus, it may be said that the CFD serves as a useful tool for pump designs.

  • PDF

Design and Operation Characteristics of a Two-Stage Compressor (이단 압축기의 동력학적 설계 및 운전 특성에 관한 연구)

  • Lee, Yong-Bok;Kim, Tae-Ho;Kim, Chang-Ho;Lee, Nam-Soo;Choi, Dong-Hoon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.1 s.14
    • /
    • pp.55-61
    • /
    • 2002
  • The feasibility of an oil-free, motor-driven, two-stage centrifugal compressor supported by air bump bearings is investigated. This centrifugal compressor is driven by a 75 kW motor at an operating speed of 39,000 RPM, and a pressure ratio of the compressor is set up to 4. The analysis is performed by using bearing equilibrium position, heaving stillness, Campbell diagram, unbalance response, and stability. It is demonstrated in this paper that air bump bearings can be adopted well to an oil-free, motor-driven, centrifugal compressor. Specially, Cu-coated bump bearings have enough damping force to reduce a synchronous unbalance for rigid modes of the two-stage compressor. Futhermore, this concept may be applied to the flexible rotor system such as high speed turbomachinery with a super critical speed.

Investigation of Off-Design Performance of Vaned Diffusers in Centrifugal Compressors - Part II : Low Solidity Cascade Diffuser - (원심압축기용 베인디퓨져의 탈설계점 성능연구 - 제2부 : 솔리디티가 작은 익렬디퓨져 -)

  • Oh, JongSik;Lee, HeonSeok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.91-98
    • /
    • 2001
  • As the second part of the author's study, off-design behavior of the design and performance parameters in the low-solidity cascade diffuser in a centrifugal compressor is investigated. The experimental flange-to-flange compressor map serves the validity of application of the present CFD work to the detailed investigation of the low-solidity cascade diffuser. Some meanline design and performance parameters as well as three-dimensional internal secondary flow fields are studied when the flow rate is changed from deep choke to stall.

  • PDF

Impeller Redesign of Multi-stage Centrifugal Pumps (다단 원심펌프 임펠러의 개량 수력설계)

  • Oh, JongSik;Kim, DongSoo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.177-184
    • /
    • 2001
  • For two kinds of the multi-stage centrifugal pump with diffuser vanes and return channel vanes the meanline performance prediction is applied to get information of hydraulic performance at each internal flow station, because only flange-to-flange test curves are available. As a first step of redesign fur higher efficiency, the impeller geometry is numerically investigated in the present study. Quasi-3D inviscid loading distributions are obtained, for the two impellers, using the state-of-the-art method of impeller 3D design, which provides a guide to optimal redesign. Full 3D turbulent flow fields are thereafter analyzed, using the specialized CFD code, to confirm the redesign results. The inherent limitation of the traditional graphic method of impeller design, which most of domestic pump manufacturers are now employing, is found.

  • PDF

Design and Operation Characteristics of A Two-Stage Compressor (이단 압축기의 동력학적 설계 및 운전 특성에 관한 연구)

  • Lee, Yong-Bok;Lee, Nam-Soo;Kim, Tae-Ho;Kim, Chang-Ho;Choi, Dong-Hoon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.469-474
    • /
    • 2001
  • The feasibility of a oil-free motor-driven two-stage centrifugal compressor supported by air bump bearings is investigated. This centrifugal compressor is driven by 75kW motor at an operating speed of 39,000RPM md a pressure ratio of the compressor is up to 4. The analysis is performed, based upon bearing equilibrium position, bearing stiffness, Campbell diagram, unbalance response and stability. It is demonstrated in this paper that air bump bearings can be adopted well to a oil-free motor-driven centrifugal compressor.

  • PDF

Numerical Study on the Unsteady Flow in the Vaned Diffuser of Centrifugal Compressor (원심 압축기 베인 디퓨져내 비정상 유동의 수치해석적 연구)

  • Hwang, Sung-Mok;Han, Wha-Taek;Kim, Won-Kap
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.113-119
    • /
    • 2001
  • Interaction of flow through an Impeller and a Vaned Diffuser in Centrifugal Compressor was investigated using the 3-dimensional Wavier-Stokes solution method. To consider the interaction effect of impeller and vaned diffuser, Inlet boundary conditions are imposed with the results of the steady calculation of the impeller and rotates with time. The results have been compared to steady computation results and experiment. From this, it is discussed about the compatability of the method and the advantage and disadvantage of the steady calculation.

  • PDF

Flow characteristics at the Impeller Exit of a Centrifugal Pump (원심펌프의 회전차 출구 유동 특성)

  • Hong, Soon-Sam;Kang, Shin-Hyoulg
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.36-44
    • /
    • 2000
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A hot-film probe and a high response pressure transducer are used to investigate the flow at impeller exit and vaneless diffuser region for design and off design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, design, and numerical analysis of pumps.

  • PDF

Effect of Fluid Viscosity Changes on Pump Performances (유체의 점도변화가 펌프성능에 미치는 영향)

  • Cho, Mintae;Suh, Sangho;Kim, Dongjoo;Sung, Sunkyung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.61-64
    • /
    • 2000
  • In order to analyse the effect of the fluid viscosity changes on the centrifugal pump, the computer simulation method and the performance correction chart are used. The centrifugal pump is designed using the traditional method, and the 3D computational grid is generated for the impeller and casing. Working fluids are water, high viscous oil and muddy water. The viscosity of muddy water is measured by the unsteady capillary tube viscometer. The pump performances are predicted well through the computer simulation. The performance curves of head and efficiency for oil and muddy water are decreased. The torques of oil and muddy water, which is calculated by performance correction chart are predicted at a lower value than the computer simulation.

  • PDF

Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex (Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동)

  • Kim, Cheol Hong;Ju, Young Ho;Byun, Hyung Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

Performance Analysis of the Centrifugal Pump Impeller Using Commercial CFD Code (상용 CFD코드를 이용한 원심펌프 임펠러의 성능해석)

  • Choi, Young-Seok;Lee, Yong-Kab;Hong, Soon-Sam;Kang, Shin-Hyung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.305-311
    • /
    • 2000
  • A commercial CFD code is used to compute the 3-D viscous flow field within the impeller o( a centrifugal pump. Several preliminary numerical calculations are carried out to determine the influence of the parameters such as the grid systems, the numerical schemes, the turbulence models and the shape of the vaneless diffusers at the design flow rate. The results of the preliminary study are used for the calculation of the off-design flow conditions. The circumferentially averaged results such as the radial and tangential velocities, the exit flow angle, the slip factor, the static pressure and the total pressure are compared with the experimental data at the impeller exit to discuss the influence of the prescribed parameters.

  • PDF