• 제목/요약/키워드: Centralized Monitoring System

검색결과 60건 처리시간 0.024초

동기식광전송장치(SMOT-1/4/16)의 통합 운용관리시스템 구현 (The Intergrated O&M System for SMOT(Synchronous Multiplexing and Optical Transmission) System level-1/4/16)

  • 배광용;이동원김정수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.195-198
    • /
    • 1998
  • In Korea Telecom, many synchronous optical transmission equipments and its operating terminal (PC) have been operated. However, many equipment operators have requested various supplementary functions such as self-monitoring and taking statistical information. This system has tried to solve the above problems, and therefore to establish centralized monitoring system on synchronous transmission equipments based on telephone office unit.

  • PDF

Implementation of Medical Device Integration Module for Integrated Patient Monitoring System

  • Park, Myeong-Chul;Jung, Hyon-Chel;Choi, Duk-Kyu
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권6호
    • /
    • pp.79-86
    • /
    • 2017
  • In this paper, we implement a common module that can integrate multiple biometric information for integrated patient monitoring system. Conventional biomedical instruments have many devices attached to each patient, making it difficult to monitor abnormality signs of many patients in real time. In this paper, we propose a module for an integrated monitoring system that can perform centralized monitoring using a common module that integrates multiple measurement devices. A protocol for sending and receiving packets between the measuring device and the common module is designed, and the packets transmitted through the network are stored and managed through the integrated monitoring system and provide information to various users such as medical staff. The results of this study are expected to contribute to the management of patients and efficient medical services in hospitals.

Remote Vital Signal Monitoring System Based on Wireless Sensor Network Using Ad-Hoc Routing

  • Walia Gaurav;Lee Young-Dong;Chung Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • 제4권2호
    • /
    • pp.67-70
    • /
    • 2006
  • A distributed healthcare monitoring system prototype for clinical and trauma patients was developed, using wireless sensor network node. The proposed system aimed to measure various vital physiological health parameters like ECG and body temperature of patients and elderly persons, and transfer his/her health status wirelessly in Ad-hoc network to remote base station which was connected to doctor's PDA/PC or to a hospital's main Server using wireless sensor node. The system also aims to save the cost of healthcare facility for patients and the operating power of the system because sensor network is deployed widely and the distance from sensor to base station was shorter than in general centralized system. The wireless data communication will follow IEEE 802.15.4 frequency communication with ad-hoc routing thus enabling every motes attached to patients, to form a wireless data network to send data to base-station, providing mobility and convenience to the users in home environment.

전력감시제어설비(SCADA)의 open system architecture 적용 (The application of open system architecture in power SCADA system)

  • 이용해;문국연;박장범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.992-995
    • /
    • 1996
  • The major roles of Power SCADA System are continuous monitoring of electrical equipments state, real-time data processing and dispatching. Especially, SCADA system demands fast response time in heavy load condition, high reliability, fault tolerance, expansion capacity for the future. According to developing computer system technology, SCADA system is changing system configuration from centralized processing system to distributed processing system. This paper describes operational benefits, problems and improvement (which is studying in theory) in the application of Open System Architecture SCADA which has been installed since 1994, Seoul regional control center in KEPCO.

  • PDF

JINI 기반 원격 응용 모니터링 시스템 (A Remote Applications Monitoring System using JINI)

  • 임성훈;송무찬;김정선
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제10권3호
    • /
    • pp.221-230
    • /
    • 2004
  • 원격 모니터링 시스템이란 네트웍에 분산된 호스트 혹은 원격 어플리케이션의 상태를 실시간으로 모니터링 하는 시스템이다. 네트웍에 분산된 호스트들은 다양한 플랫폼을 갖추고 있는 것이 현실이다. 하지만, 기존의 모니터링 시스템들은 플랫폼에 의존적인 성격을 띠고 있다. 네트웍을 통해서 모니터링을 하기 때문에 잠재적인 네트웍의 문제발생에 대한 적절한 대응이 필요하지만, 기존의 모니터링 시스템들은 네트웍의 문제에 대해서 적절하게 대응을 못하고 있다. 그리고 호스트의 상태를 변화시키는 요인은 호스트의 시스템 자원보다는 어플리케이션의 상태변화가 주 요인이 되고 있지만, 기존의 시스템들은 주로 호스트의 상태정보만 모니터링을 하고 있다. 따라서, 분산된 호스트들의 플랫폼에 독립적이고, 네트웍의 잠재적인 문제발생을 적절하게 대응을 할 수 있고, 호스트의 상태정보 보다는 호스트의 어플리케이션의 상태정보를 모니터링 하는 시스템이 필요한 실정이다. 본 논문에서는 네트웍에 분산된 어플리케이션의 실시간 모니터링을 통해서 어플리케이션 상태를 효과적으로 관리할 수 있는 모니터링 시스템인 RAMS (Remote Applications Monitoring System)의 설계 및 구현을 제시한다. 이 시스템은 네트웍에 분산된 호스트들의 효과적인 관리를 위해 호스트 어플리케이션의 상태를 모니터링 한다. RAMS는 모니터링 대상인 호스트 어플리케이션의 모니터링을 담당하는 Agent, 호스트의 등록, 관리를 담당하는 Manager로 구성된다. Manager와 Agent는 네트웍 단절 혹은 호스트 failure의 상황에도 자동으로 복구가 가능할 수 있도록 JINI를 최대한 활용함으로써 다른 시스템에 비해 시스템의 구성 및 관리가 용이한 특성을 갖는다.

디지털콘덴츠 집중관리를 위한 표준화에 관한 연구 (A Study on Standardization of Copyright Collective Management for Digital Contents)

  • 조윤희;황도열
    • 정보관리학회지
    • /
    • 제20권1호
    • /
    • pp.301-320
    • /
    • 2003
  • 인터넷 이용의 폭발적인 증가와 통신망의 발달, 개인 홈페이지에서 전문 정보서비스에 이르는 디지털콘텐츠의 폭증, 새로운 파일교환 서비스의 등장과 해킹기술의 발달은 디지털콘텐츠의 복제와 배포를 더욱 확산시킴으로서 해당 저작물의 저작권자가 법적으로 보장받던 배타적 권리를 심각하게 위협하고 있다. 이에 디지털콘텐츠 권리의 원활한 거래와 확실한 요금부과, 보안대책, 부정이용 감시 등 저작권자와 이용자간의 가교역할을 할 수 있는 집중관리를 위한 디지털저작권관리시스템 구축이 절실히 요구되고 있다. 따라서 본 연구는 디지털콘텐츠의 원활한 유통을 지원할 수 있도록 집중관리제도의 도입을 위한 법적, 제도적 검토와 국내외 저작권집중관리제도의 현황을 파악하였다. 아울러 디지털콘텐츠 집중관리의 핵심이 되는 유일한 식별을 위한 식별체계와 데이터 요소의 표준화 및 디지털저작권관리(DRM) 검토를 통하여 디지털콘텐츠 저작권관리정보의 표준화에 기초자료를 제공하고자 하였다.

태양열 온수기 실증연구를 통한 성능 평가 (Performance Evaluation of Solar Water Heating System Using Proof Test)

  • 김재열;곽이구;양동조;최철준;김홍건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

Design and performance validation of a wireless sensing unit for structural monitoring applications

  • Lynch, Jerome Peter;Law, Kincho H.;Kiremidjian, Anne S.;Carryer, Ed;Farrar, Charles R.;Sohn, Hoon;Allen, David W.;Nadler, Brett;Wait, Jeannette R.
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.393-408
    • /
    • 2004
  • There exists a clear need to monitor the performance of civil structures over their operational lives. Current commercial monitoring systems suffer from various technological and economic limitations that prevent their widespread adoption. The wires used to route measurements from system sensors to the centralized data server represent one of the greatest limitations since they are physically vulnerable and expensive from an installation and maintenance standpoint. In lieu of cables, the introduction of low-cost wireless communications is proposed. The result is the design of a prototype wireless sensing unit that can serve as the fundamental building block of wireless modular monitoring systems (WiMMS). An additional feature of the wireless sensing unit is the incorporation of computational power in the form of state-of-art microcontrollers. The prototype unit is validated with a series of laboratory and field tests. The Alamosa Canyon Bridge is employed to serve as a full-scale benchmark structure to validate the performance of the wireless sensing unit in the field. A traditional cable-based monitoring system is installed in parallel with the wireless sensing units for performance comparison.

표면온도 알고리즘을 통한 옥상녹화통합형 태양광시스템의 출력 모니터링 연구 (A Study on Output Monitoring of Green Roof Integrated PV System through Surface Temperature Algorithm)

  • 김태한;박상연
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.89-95
    • /
    • 2015
  • The centralized power supply system and rainwater treatment system, which are major infrastructure in modern cities, are showing their limitations in accommodating environment load due to climate changes that has aggravated recently. As a result, complex issues such as shortage of reserve power and urban flooding have emerged. As a single solution, decentralized systems such as a model integrating photovoltaic system and rooftop greening system are suggested. When these two systems are integrated and applied together, the synergy effect is expected as the rooftop greening has an effect of preventing urban flooding by controlling peak outflow and also reduces ambient temperature and thus the surface temperature of solar cells is lowered and power generation efficiency is improved. This study aims to compare and analyze the monitoring results of four algorithms that define correlations between micro-climate variables around rooftop greening and the surface temperature of solar cells and generate their significance. By doing so, this study seeks to present an effective algorithm that can estimate the surface temperature of solar cell that has direct impact on the efficiency of photovoltaic power generation by observing climate variables.

능동 데이터베이스 기반 무효전력 보상장치 감시제어 시스템 (A Reactive Power Compensation Monitoring System for Factory Electrical Installation Using Active Database)

  • 최상열
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.189-194
    • /
    • 2012
  • 수배전 무효전력 보상 감시 제어시스템은 수배전단에 설치된 유도 모터, 또는 아크 용접기 등과 같은 유도성 부하에서 발생되는 지상무효전력을 보상하고 역률의 개선, 전압 강하의 경감, 전력손실을 감소 시켜줌으로써 전력설비 계통을 경제적이고 안정적으로 운영하도록 도와준다. 그리고 이러한 시스템은 중앙전력감시반이 획득한 수변전설비의 운전상태 및 계측 Data를 근거로 역률 및 위상각을 분석하여 기준 위상각이상으로 전압과 전류의 위상차가 발생 되었을 경우, 무효전력 보상장치의 ON/OFF제어를 수행하여 효율적인 계통관리가 가능하도록 한다. 본 연구에서는 능동데이터베이스를 이용하여 무효전력 보상장치 감시제어 시스템을 구현하는 방안을 제시함으로써, 공장 부하의 지상무효전력이 급격한 증가로 인한 역률 저하, 전압 강하, 손실 발생 등의 징후 발생 시 이에 대한 대처를 사용자(operator)의 개입 없이 데이터베이스 스스로 수행하도록 함으로써 인위에 의한 실수를 최소화 하도록 하였다.