• Title/Summary/Keyword: Central vein cannulation

Search Result 7, Processing Time 0.023 seconds

A Study on Central Vein Cannulation Using Audible Doppler Guidance in Children and Infants (Audible Doppler Ultrasound(8 MHz)를 이용한 소아와 영아에서 중심정맥 도관 삽입술에 관한 연구)

  • Ahn, Young Joon;Jung, Jin Young;Hong, Soo-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1120-1125
    • /
    • 2002
  • Purpose : Percutaneous cannulation of the central vein in children and infants may be technically difficult and can cause serious complications. There are many techniques to improve the success rate and to decrease the complications in central vein cannulation. This study was undertaken to determine whether audible Doppler guidance can help operators improve the results of central vein cannultion in pediatric ICU. Methods : A total of 46 central vein cannulations were performed using audible Doppler guidance technique. Using an 8-MHz Doppler ultrasound device(Pocket-Dop II. iMex. USA), the artery and the vein were identified by their characteristic Doppler sounds. Results : There was a total of 46 patients with 20 boys and 26 girls, respectively. The mean age was $3years{\pm}45months$(range : 1-156 months). The number of infants was 18 and the mean age was $6.3{\pm}3.8$ months(range : 1-12 months). The most common site of central vein cannulation was the right internal jugular vein(63%). The cannulation was successful in 44 out of 46 procedures(96%). The success rate at the first attempt was 59% with 48% in the patients who had the history of previous cannulation and 70% in the patients who did not, respectively. The success rate in infants was 94%(17 out of 18). The average access time was $5.2{\pm}8.3$ minutes in children contrary to $7.5{\pm}10.3$ minutes in infants. There were no serious complications, but six patients had complications including four hematoma, one arterial puncture, and one pneumothorax. Conclusion : This central vein cannulation using Doppler guidance may improve the success rate of central vein cannulation and decrease the development of serious complications in infants and children.

Ultrasound-guided internal jugular vein catheterization in critically ill pediatric patients

  • Yang, Eu Jeen;Ha, Hyeong Seok;Kong, Young Hwa;Kim, Sun Jun
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.4
    • /
    • pp.136-141
    • /
    • 2015
  • Purpose: Continuous intravenous access is imperative in emergency situations. Ultrasound-guided internal jugular vein (IJV) catheterization was investigated in critically ill pediatric patients to assess the feasibility of the procedure. Methods: Patients admitted to the pediatric intensive care unit between February 2011 and September 2012 were enrolled in this study. All patients received a central venous catheter from attending house staff under ultrasound guidance. Outcome measures included successful insertion of the catheter, cannulation time, number of cannulation attempts, and number and type of resulting complications. Results: Forty-one central venous catheters (93.2%) were successfully inserted into 44 patients (21 males and 23 females; mean age, $6.54{\pm}1.06$ years). Thirty-three patients (75.0%) had neurological disorders. The right IJV was used for catheter insertion in 34 cases (82.9%). The mean number of cannulation attempts and the mean cannulation time was $1.57{\pm}0.34$ and $14.07{\pm}1.91$ minutes, respectively, the mean catheter dwell time was $14.73{\pm}2.5$ days. Accidental catheter removal was observed in 9 patients (22.0%). Six patients (13.6%) reported complications, the most serious being catheter-related sepsis, which affected 1 patient (2.3%). Other complications included 2 reported cases of catheter malposition (4.6%), and 1 case each of arterial puncture (2.3%), pneumothorax (2.3%), and skin infection (2.3%). Conclusion: The results suggest that ultrasound-guided IJV catheterization can be performed easily and without any serious complications in pediatric patients, even when performed by visiting house staff. Therefore, ultrasound-guided IJV catheterization is strongly recommended for critically ill pediatric patients.

Accidental Vertebral Artery Cannulation as a Complication of the Central Venous Catherization (우발적인 척추동맥으로의 중심정맥 카테터의 삽관)

  • Jeong, Ju Ho
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.33-37
    • /
    • 2014
  • Central venous catheterization through a subclavian approach is indicated for some special purposes but it may cause many complications such as infection, bleeding, pneumothorax, thrombosis, air embolization, arrhythmia, myocardial perforation, and nerve injury. A case involving a mistaken central venous catheterization into the right vertebral artery through the subclavian artery is presented. A 33-year-old man who had deteriorated mentality after head injury underwent an emergency craniotomy for acute epidural hematomas on the right frontal and temporal convexities. His mentality improved rapidly, but he complained of continuous severe pain in the right posterior neck even though he had no previous symptom or past medical history of such pain. Three-dimensional cervical spine computed tomography (3D-CT) was performed first to rule out unconfirmed cervical injuries and it revealed a linear radiopaque material intrathoracically from the level of the 1st rib up to the level of C6 in the right vertebral foramen. An additional neck CT was performed, and the subclavian catheter was indwelling in the right vertebral artery through right subclavian artery. For the purpose of proper fluid infusion and central venous pressure monitoring, the subclavian vein catheterization had been performed in the operation room after general anesthesia induction before the craniotomy. Sufficient anatomical consideration and prudence is essential because inadvertent arterial cannulation at a non-compressible site is a highly risky iatrogenic complication of central venous line placement.

A Safe Method of Central Venous Catheterization by Peripheral Venous Cutdown in Infants (소아에서 말초정맥을 이용한 중심정맥로 확보법)

  • Han, Seck-Joo;Choi, Seung-Hoon;Hwang, Eui-Ho
    • Advances in pediatric surgery
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 1995
  • Percutaneous infraclavicular subclavian catheterization has been widely used for a total parenteral nutrition, hemodynamic monitoring and for venous access in difficult clinical situations. Many authors have claimed the infraclavicular cannulation of the subclavian vein in the tiniest infants can be performed with safety and ease, but there are always possibility of serious complications in this method. We present our experiences of peripheral venous cutdown with Broviac catheter. Author routinely introduced Broviac catheter into central vein via peripheral venous cutdown. There was no life threatening complications and no catheter related death. The complication rate was very low. The catheter related sepsis was documented in only two patient(4.7%). The average catheter longivity was 19.59 days. In view of the safety and low rate of complication, we think that peripheral venous cutdown with Broviac catheter should be the method of choice when central venous access is necessary in infants. The infraclavicular subclavian catheterization should be reserved in infants with few accessible peripheral vein.

  • PDF

Urgent Endovascular Stent Graft Placement for Iatrogenic Subclavian Artery Rupture (의인성 쇄골하정맥 파열로 인한 응급 혈관내 스텐트 삽입)

  • Kang, Byung-Woo;BAE, Jun-ho;Chung, Jin-Wook;Jo, Byeong-Joo;Park, Jun-Gi;Nah, Deuk-Young
    • Journal of Trauma and Injury
    • /
    • v.28 no.2
    • /
    • pp.83-86
    • /
    • 2015
  • Central venous cannulation is one of the most commonly performed procedures for critically ill patients in the emergency room. Serious complications like a rupture of subclavian artery may occur during this procedure. We report a case of successful stent graft deployment for iatrogenic ruptured subclavian artery after attempted right subclavian vein catheterization in a 31 year-old female patient with hypovolemic shock due to cervical os laceration during vaginal delivery.

  • PDF

Sternal Retraction and Subclavian Vein Catheter Occlusion during Cardiac Surgery

  • Tarbiat, Masoud;Bakhshaei, Mohammad Hossein;Derakhshanfar, Amir;Rezaei, Mahmoud;Ghorbanpoor, Manoochehr;Zolhavarieh, Seyed Mohammad
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.377-382
    • /
    • 2021
  • Background: Subclavian vein (SV) catheterization is a method for the delivery of fluids, drugs, and blood products, venous blood sampling, and central vein pressure monitoring in cardiac surgery. Catheter occlusion is a serious complication of SV catheterization during cardiac surgery, especially after sternal retractor expansion. Methods: In this observational study, 303 patients who had successful right infraclavicular SV catheterization from September 2019 to April 2020 were enrolled to determine the incidence of catheter occlusion. After catheterization, the lumens of all catheters were checked for the ability to infuse and withdraw blood from the catheter before and after sternal retractor expansion. The patients' characteristics, cannulation approach, on-pump or off-pump technique, occlusion of the catheter and its lumens, and any associated complications were recorded. The data were analyzed using IBM SPSS ver. 22.0 (IBM Corp., Armonk, NY, USA). Results: Of the 303 patients studied, 205 were male (67.7%) and 98 were female (32.3%). Catheter occlusion occurred in 11 patients with on-pump cardiopulmonary bypass (CPB) (227 patients) and 4 patients with off-pump CPB (76 patients) (p=0.863). The incidence of catheter occlusion was 4.95% (15 of 303 patients) with no cases of simultaneous 3-lumen occlusion in a catheter. The most commonly occluded lumen was the distal lumen (57.92%). Simultaneous 2-lumen occlusion occurred in 4 patients. Catheter occlusion was found in 3 of 13 malpositioned catheters (23.07%). Conclusion: The current study showed that malpositioning of the catheter tip was a risk factor for catheter occlusion and that the distal lumen of a triple-lumen catheter was the most commonly occluded lumen.

Capsaicin Induces Acute Spinal Analgesia and Changes in the Spinal Norepinephrine Level (Capsaicin에 의한 척수 수준에서의 급성 진통효과와 Norepinephrine의 변화)

  • Park, Hyoung-SuP;Park, Kyung-Pyo
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.1
    • /
    • pp.33-41
    • /
    • 1993
  • Central analgesic effect of capsaicin was assessed by the tail flick reflex (TFR) test, using male Sprague-Dawley rats under anesthesia with pentobarbital sodium (induction with 40 mg/kg and maintenance with $4{\sim}8\;mg/kg/hr$). Level of norepinephrine in the spinal cord was also measured. Capsaicin, $35{\sim}150\;{\mu}g$, was injected intrathecally, and the TFR latency was measured before, 10, 30, and 60 minutes after the drug administration. TFR latency was increased 100% or more immediately by intrathecal capsaicin, from 2.9 seconds to the maximum of 7.0 seconds at 10 minute after the drug; P<0.01. The increase in TFR latency was maintained during the course of experiment of 2 hours. Concomitant reduction of NE content in the spinal cord was observed; from 16 ng/mg protein to 7 ng/mg protein. On the other hand, subcutaneous injection of capsaicin of 50 mg/kg did not change the TFR latency although the NE content reduced similarly to the case of intrathecal injection. Pretreatment of the animal with 0.5 mg/kg of MK-801 reversed the increase of TFR latency and NE reduction induced by intrathecal capsaicin. These results suggest that capsaicin causes analgesia at the spinal cord level by activating the excitatory amino acid-NE-dorsal horn interneurons axis of the descending inhibitory pain modulation pathway.

  • PDF