• Title/Summary/Keyword: Central pressure

Search Result 933, Processing Time 0.019 seconds

An Efficient and Mild Oxidation of α-Isophorone to Ketoisophorone Catalyzed by N-Hydroxyphthalimide and Copper Chloride

  • Chen, Lihua;Tang, Ruiren;Li, Zhongying;Liang, Shan
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.459-463
    • /
    • 2012
  • N-hydroxyphthalimide (NHPI) and copper chloride ($CuCl_2$) were first utilized for aerobic oxidation of ${\alpha}$-isophorone (${\alpha}$-IP) to ketoisophorone (KIP) and the effects of co-catalysts, temperature, reaction time, solvent, amount of $CuCl_2$ and pressure of oxygen were investigated extensively. NHPI/$CuCl_2$ turned out to be highly efficient to this oxidation with up to 91.3% conversion and 81.0% selectivity under mild conditions. And various hydrocarbons including benzylic compounds, cycloalkene and its derivatives were also oxidized smoothly under optimized conditions. Moreover, the possible reaction mechanism was proposed and verified by FT-IR spectra.

A Novel Technology for Recycling Waste Dry-battery

  • Chen, Weiliang;Chai, Liyuan;Min, Xiaobo;Zhang, Chuanfu
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.249-251
    • /
    • 2001
  • A novel technology for recycling valuable metals contained in waste dry-battery by vacuum metallurgy was devised by theoretical analysis. On the condition of the total chamber pressure of 1.013$\upsilon$10$^1$Pa, Hg, Cd and Zn are distilled in the temperature range of 773~973K, Pb is volatilized in the range of 1173~1273K while Mn, Cu, Fe and C are remained in residual. MnO$_2$and ZnO are reduced by carbon in waste dry-battery in 773~1273K. Pure metals including Zn, Cd, Hg and Pb can be recovered respectively from their mixed vapor by fractional condensation. Metal Cu and MnO$_2$can be obtained from the residual by hydrometallguical method. The technology can eliminate the pollution of Cd, Hg and Pb to environment.

  • PDF

Massive hemothorax after central venous catheter insertion in a patient with multiple trauma

  • Park, Jeong Heon;Song, Jaegyok;Oh, Pyeong-wha
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.1
    • /
    • pp.81-85
    • /
    • 2021
  • Central venous catheter (CVC) insertion is commonly used in the operating room and intensive care unit to monitor central venous pressure and secure an intravenous route to deliver medications and nutritional support that cannot be safely infused into peripheral veins. However, CVC insertion may be associated with serious complications such as arterial puncture, hematoma, pneumothorax, hemothorax, catheter infections, and thrombosis. Several methods have been recommended to prevent these complications. Here we report a case of massive hemothorax caused by attempts of CVC insertion into the internal jugular vein and subclavian vein in a patient with multiple trauma. CVC placement should be performed or supervised by an experienced physician to decrease the incidence of CVC-related complications. CVC insertion under ultrasound guidance is recommended.

Synthesis of solid enantioselective macromer of trimesic acid for the enantiomeric separation of chiral alcohols

  • Ingole, Pravin G.;Bajaj, Hari C.;Singh, Kripal
    • Advances in materials Research
    • /
    • v.2 no.1
    • /
    • pp.51-64
    • /
    • 2013
  • Enantioselective macromer of trimesic acid was prepared using S(-) menthol with trimesoyl chloride on polyimide (PI) ultrafiltration membrane. The chemical composition of macromer as well as polyimide ultrafiltration membrane was determined by ATR-FTIR Spectroscopy. The optical resolution of chiral alcohols was performed in pressure driven process. The effect of monomer solutions concentration, effect of air-drying time of S(-) menthol solution, effect of reaction time, effect of operating pressure, effect of feed concentration of racemate on the performance of macromer was studied. The synthesised material exhibits separation of chiral alcohols (menthol ~23% and sobrelol ~21%).

A Comparative Study of the Postoperative Cardiac Performance after Repair of Congenital Heart Defects with Crystalloid and Blood Cardioplegic Solution (Crystalloid Cardioplegic Solution과 Blood Cardioplegic Solution을 사용한 선천성 심기형 환자에서의 술 후 심기능 평가에 대한 비교 연구)

  • Kim, Yong-Jin;Kim, Yeong-Tae
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.815-823
    • /
    • 1994
  • This study was undertaken to hemodynamically determine the differences of myocardial protective effect between crystalloid and blood cardioplegic solution. Twenty nine children undergoing cardiac operations due to cyanotic congenital heart diseases were randomized into two groups receiving crystalloid or blood cardioplegia. Cardiac indices and other hemodynamic datum were examined postoperatively. Although there was no statistical differences between groups, postoperative stroke volume indices and left ventricular stroke work indices were slightly better with blood cardioplegia. We also found that postoperative left atrial pressures[p=0.0003], central venous pressures[p=0.004], and heart rates[p=0.014] were significantly lower with blood cardioplegia. The fact that relatively lower ventricular preloads [left atrial pressure and central venous pressure] were required to provide adequate cardiac output in blood cardioplegia group suggested superior myocardial protective effect of blood cardioplegic solution.

  • PDF

Experimental investigation of vortex-induced aeroelastic effects on a square cylinder in uniform flow

  • Huang, Dongmei;Wu, Teng;He, Shiqing
    • Wind and Structures
    • /
    • v.30 no.1
    • /
    • pp.37-54
    • /
    • 2020
  • To investigate the motion-induced aeroelastic effects (or aerodynamic feedback effects) on a square cylinder in uniform flow, a series of wind tunnel tests involving the pressure measurement of a rigid model (RM) and simultaneous measurement of the pressure and vibration of an aeroelastic model (AM) have been systematically carried out. More specifically, the aerodynamic feedback effects on the structural responses, on the mean and root-mean-square wind pressures, on the power spectra and coherence functions of wind pressures at selected locations, and on the aerodynamic forces were investigated. The results indicated the vibration in the lock-in range made the shedding vortex more coherent and better organized, and hence presented unfavorable wind-induced effects on the structure. Whereas the vibration in the non-lock-in range generally showed insignificant effects on the flow structures surrounding the square cylinder.

Feasibility study on corrosion monitoring of a concrete column with central rebar using BOTDR

  • Sun, Yijie;Shi, Bin;Chen, Shen-En;Zhu, Honghu;Zhang, Dan;Lu, Yi
    • Smart Structures and Systems
    • /
    • v.13 no.1
    • /
    • pp.41-53
    • /
    • 2014
  • Optical fiber Brillouin sensor in a coil winding setup is proposed in this paper to measure the expansion deformation of a concrete column with a central rebar subjected to accelerated corrosion. The optical sensor monitored the whole dynamic corrosion process from initial deformation to final cracking. Experimental results show that Brillouin Optical Time Domain Reflectometer (BOTDR) can accurately measure the strain values and identify the crack locations of the simulated reinforced concrete (RC) column. A theoretical model is used to calculate the RC corrosion expansive pressure and crack length. The results indicate that the measured strain and cracking history revealed the development of the steel bar corrosion inside the simulated RC column.

An Elastohydrodynamic Lubrication of Elliptical Contacts : Part II - The Effect of Spin Motion (타원접촉의 탄성유체윤활 : 제2보 - 스핀운동의 영향)

  • Park, Tae-Jo
    • Tribology and Lubricants
    • /
    • v.23 no.2
    • /
    • pp.49-55
    • /
    • 2007
  • A numerical analysis of elastohydrodynamic lubrication of elliptical contacts with both rolling and spinning has been carried out. A finite difference method with non-uniform grid systems and the Newton-Raphson method are applied to solve the problems. The velocity vectors resulting from combined spinning and rolling/sliding motion lead to asymmetric pressure distributions and film shapes. Pressure distributions, film contours and variations of the minimum and central film thicknesses are compared with various spin-roll ratios. Reduction of the minimum film thickness under spinning is remarkable whereas the central film thickness is relatively less. The spin motion have large effect on variations of the minimum film thickness with load parameter which are small in pure rolling/sliding cases. Therefore present numerical scheme can be used in the analysis of general elliptical contact EHL problems and further studies are required.

Reliability analysis of shallow tunnel with surface settlement

  • Yang, X.L.;Li, W.T.
    • Geomechanics and Engineering
    • /
    • v.12 no.2
    • /
    • pp.313-326
    • /
    • 2017
  • Based on the reliability theory and limit analysis method, the roof stability of a shallow tunnel is investigated under the condition of surface settlement. Nonlinear Hoek-Brown failure criterion is adopted in the present analysis. With the consideration of surface settlement, the internal energy and external work are calculated. Equating the rate of energy dissipation to the external rate of work, the expression of support pressure is derived. With the help of variational approach, a performance function is proposed to reliability analysis. Improved response surface method is used to calculate the Hasofer-Lind reliability index and the failure probability. In order to assess the validity of the present results, Monte-Carlo simulation is performed to examine the correctness. Sensitivity analysis is used to estimate the influence of different variables on reliability index. Among random variables, the unit weight significantly affects the reliability index. It is found that the greater coefficient of variation of variables lead to the higher failure probability. On the basis of the discussions, the reliability-based design is achieved to calculate the required tunnel support pressure under different situations when the target reliability index is obtained.

Design of Centrifugal Impeller for Passenger Car by Flow Field Analysis (유동장 해석을 통한 승용차 원심 회전차의 형상 설계)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.49-55
    • /
    • 2011
  • For the purpose of the enhancement of the air conditioner performance and fuel effciency, several cases of centrifugal impeller for passenger car air conditioner have been numerically analyzed by changing central angle of blades and length of outlet for shape optimization of the impeller. Commercial CFD program Fluent 6.3.26 has been used to compute velocity, temperature, pressure and turbulence intensity that can lead numerous results. The central angles of two blades and three cases of outlet length led 4~12% and 3.5~6.4% differences of velocity and flow rate, respectively. The velocity distribution near the blade surface was axisymmetric and had a maximum value of 22.19 m/s and velocity of the vertical direction of the impeller showed linear increase with horizontal direction. At case 3 of oultet length, there existed a a minimum pressure value of -133320 Pa.