• 제목/요약/키워드: Central fatigue

검색결과 112건 처리시간 0.028초

반응표면법에 의한 레디어스로드 최적구조설계 및 피로해석 (Optimal Structural Design and Fatigue Analysis of Radius Rod by Response Surface Method)

  • 박소현;김은성;오상엽;유효선;양성모;김용관
    • 한국자동차공학회논문집
    • /
    • 제22권1호
    • /
    • pp.29-35
    • /
    • 2014
  • This paper aims to obtain the effect of lightweight on Radius rod. The response surface method used in the paper is the statistical method. Optimization method is performed with the Radius rod using the lightweight material. Structural analysis is executed by using the ANSYS program to find static and dynamic responses. From this study result, it is verified that the response surface method has the advantage of optimum value in comparison with other optimization methods. The analysis is also performed by response surface method to derive optimal design values. Steel model and aluminium initial model are obtained by finite element analysis to clarify design criteria and the results are compared with three models each other. The weights can be reduced by optimal design analysis results of these models similar to those of existing products. The quantitative goals in this study can also attained through results of fatigue analyses. The reliability on optimal design of Radius rod can be improved by use of structural and fatigue analysis results.

Structural health monitoring of high-speed railway tracks using diffuse ultrasonic wave-based condition contrast: theory and validation

  • Wang, Kai;Cao, Wuxiong;Su, Zhongqing;Wang, Pengxiang;Zhang, Xiongjie;Chen, Lijun;Guan, Ruiqi;Lu, Ye
    • Smart Structures and Systems
    • /
    • 제26권2호
    • /
    • pp.227-239
    • /
    • 2020
  • Despite proven effectiveness and accuracy in laboratories, the existing damage assessment based on guided ultrasonic waves (GUWs) or acoustic emission (AE) confronts challenges when extended to real-world structural health monitoring (SHM) for railway tracks. Central to the concerns are the extremely complex signal appearance due to highly dispersive and multimodal wave features, restriction on transducer installations, and severe contaminations of ambient noise. It remains a critical yet unsolved problem along with recent attempts to implement SHM in bourgeoning high-speed railway (HSR). By leveraging authors' continued endeavours, an SHM framework, based on actively generated diffuse ultrasonic waves (DUWs) and a benchmark-free condition contrast algorithm, has been developed and deployed via an all-in-one SHM system. Miniaturized lead zirconate titanate (PZT) wafers are utilized to generate and acquire DUWs in long-range railway tracks. Fatigue cracks in the tracks show unique contact behaviours under different conditions of external loads and further disturb DUW propagation. By contrast DUW propagation traits, fatigue cracks in railway tracks can be characterised quantitatively and the holistic health status of the tracks can be evaluated in a real-time manner. Compared with GUW- or AE-based methods, the DUW-driven inspection philosophy exhibits immunity to ambient noise and measurement uncertainty, less dependence on baseline signals, use of significantly reduced number of transducers, and high robustness in atrocious engineering conditions. Conformance tests are performed on HSR tracks, in which the evolution of fatigue damage is monitored continuously and quantitatively, demonstrating effectiveness, adaptability, reliability and robustness of DUW-driven SHM towards HSR applications.

섬유근통 증후군에 대한 문헌고찰 (The Literature Review of FibroMyalgia Syndrome)

  • 김명철;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제16권4호
    • /
    • pp.23-37
    • /
    • 2004
  • Fibromyalgia syndrome(FMS) is a chronic pain disorder of unknown etiology characterized by widespread musculoskeletal aches and pains, stiffness, and general fatigue, disturbed sleep and sleepiness. Frequently misdiagnosed, FMS is often confused with myofascial pain syndrome, polymyalgia rheumatica, polymyositis, hypothyroidism, metastatic carcinoma, rheumatoid arthritis (RA), juvenile rheumatoid arthritis, chronic fatigue syndrome, or systemic lupus erythematosus, any of which may occur concomitantly with FMS. The management of FMS often begins with a thorough examination and a diagnosis from a physician who is formally trained in tender-point/trigger-point recognition. An initial diagnosis provides reassurance to the patient and often reduces the anxiety and depression patterns associated with FMS. The most common goals in the management of FMS are (1) to break the pain cycle, (2) to restore sleep patterns, and (3) to increase functional activity levels. Because FMS is a multifactorial syndrome, it is likely that the best treatment will encompass multiple strategies. Medication with analgesics and antidepressants and also physiotherapy, are often prescribed and give some relief. The other most effective intervention for long-term management of FS to date is physical exercise. Physical therapists can instruct patients in the use of heat at home (moist hot packs, heating pads, whirlpools, warm showers or baths, and hot pads) to increase local blood flow and to decrease muscle spasm and tension. Also instruct patients in the proper use of cold modalities (ice packs, ice massage, and cool baths) to anesthetize localized areas of pain (tender points) and break the pain cycle. Massage and tender-point massage also may promote muscle relaxation. To date, the two most important interventions for the long-term management of FS are patient education and physical exercise. Lately, is handling FMS and Chronic Fatigue syndrome(CFS) together, becuase FMS and CFS are poorly understood disorders that share similar demographic and clinical characteristics. Because of the clinical similarities between both disorders it was suggested that they share a common pathophysiological mechanism, namely, central nervous system dysfunction.

  • PDF

Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할 (The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis)

  • 이정규;김의성;강명희;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제32권2호
    • /
    • pp.130-137
    • /
    • 2007
  • 본 연구의 목적은 니켈티타늄 전동파일의 피로파절에 있어서 표면 결함의 역할을 규명하고자 fatigue tester에서 반복적 인 fatigue force를 부여한 후 파절된 단면을 주사전자현미 경으로 관찰하여 파절 역학을 규명하는 것이다. 총 45개의 #30/.04 taper와 21 mm의 HEROShaper 니켈-티타늄 전동파일을 15개씩 3개의 군으로 분류하였다. 제 1군은 결함이 없는 새 HEROShaper파일, 제 2군은 제조과정에서 metal rollover나 machining marks와 같은 표면결함을 갖는 HEROShaper파일, 제 3군은 임상에서 4- 6개의 구치부 근관의 확대에 사용한 HEROShaper 파일을 사용하였다. 모든 파일들은 회전속도(300 rpm)와 pecking distance (3 mm)가 일정하게 맞춘 fatigue tester에서 파절될 때까지 시간을 측정한 후 통계분석을 통해 각 군간의 유의성을 분석하였고, 파절 단면의 farctographic analysis를 통해 파절역학을 규명하고자 하였다 실험결과 평균 파절시간에 있어서 group 1과 2, group 1과 3사이에는 통계학적으로 유의할 만한 차이가 있었으나 (p<0.05), group 2와 3사이에는 통계학적인 차이가 없었다. Fractographic analysis 결과 대부분의 파절면에서 microvoid와 dimple 소견을 갖는 ductile fracture양상이 관찰되었다. 또한 brittle fracture가 일어난 파절면에서는 파절선 전방에 수 많은 striation들이 관찰되었고 transgranular 및 intergranular cleavage 소견도 보였다. 표면결함이 있는 제 2, 3 군의 파절단면에서는 모든 시편에서 표면결함이 관찰되었다. 이와 같은 결과로 미루어 보아 표면결함이 반복 피로파절에서 미세균열의 기시점으로 중요한 역할을 하며 fractography분석법은 Ni-Ti 파일의 파절역학을 규명하는데 유용함을 알 수 있었다.

Clinical Manifestations and Imaging Characteristics of Gliomatosis Cerebri with Pathological Confirmation

  • Zhang, Chun-Pu;Li, Hua-Qing;Zhang, Wei-Tao;Liu, Ming-Hui;Pan, Wen-Jing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4487-4491
    • /
    • 2014
  • Objective: To explore the clinical manifestations and imaging characteristics of gliomatosis cerebri to raise the awareness and improve its diagnostic accuracy for patients. Materials and Methods: Clinical data, imaging characteristics and pathological examination of 12 patients with GC from Jan., 2008 to Jan., 2012 were analyzed retrospectively. Results: Patients with GC were clinically manifested with headache, vomiting, repeated seizures, fatigue and unstable walking, most of whom had more than 2 lesions involving in parietal lobe, followed by temporal lobe, frontal lobe, periventricular white matter and corpus callosum. Magnetic resonance imaging (MRI) showed diffuse distribution, T1-weighted images (T1WI) with equal and low signals and T2-weighted images (T2WI) with bilateral symmetrical high diffuse signals. There was no reinforcement by enhancement scanning and signals were different in diffusion-weighted images (DWI). The higher the tumor staging, the stronger the signals. Pathological examination showed neuroastrocytoma in which tumor tissues were manifested by infiltrative growth in blood vessels and around neurons. Conclusions: In clinical diagnosis of GC, much attention should be paid to the diffuse distribution of imaging characteristics, incomplete matching between clinical and imaging characteristics and confirmation by combining with histopathological examination.

경사균열을 갖는 Skin/Stiffener 구조물의 보수에 의한 균열의 파괴역학적 거동 (A Fracture Mechanics Analysis of Bonded Repaired Skin/Stiffener Structures with Inclined Central Crack)

  • 정기현;양원호;김철;허성필;고명훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.292-297
    • /
    • 2001
  • Composite patch repair of cracked aircraft structures has been accepted as one of improving fatigue life and attaining better structural integrity. Analysis for the stress intensity factor at the skin/stiffener structure with inclined central crack repaired by composite stiffened panels are developed. A numerical investigation was conducted to characterize the fracture behavior and crack growth behavior. In order to investigate the crack growth direction, maximum tangential stress(MTS) criteria is used. The main objective of this research is the validation of the inclined crack patching design. In this paper, the reduction of stress intensity factors at the crack-tip and prediction of crack growth direction are determined to evaluate the effects of various non-dimensional design parameter including; composite patch thickness and stiffener distance. The research on cracked structure subjected to mixed mode loading is accomplished and it is evident that more work using different approaches is necessary.

  • PDF

볼 베어링 손상 예측진단 방법 (Prognostic Technique for Ball Bearing Damage)

  • 이도환;김양석
    • 대한기계학회논문집A
    • /
    • 제37권11호
    • /
    • pp.1315-1321
    • /
    • 2013
  • 볼 베어링의 손상 상태를 예측하기 위한 방법을 본 논문에서 제시하였다. 손상 진전율을 추정하기 위해 확률적 베어링 피로 결함 진전 모델을 적용하고 잡음이 포함된 가속도 신호의 RMS 데이터를 이용하여 손상 상태와 고장 시간을 계산하였다. 확률적 결함 진전 모델의 파라미터는 볼 베어링에 대한 일련의 Run-to-Failure 시험을 수행하여 결정하였다. 가속도 RMS값으로부터 손상 진전율과 손상 상태를 추정하기 위해 규칙화된 파티클 필터 추정 방법을 적용하였다. 미래 시점에서의 손상 상태는 최근 측정된 데이터와 직전에 추정된 상태값을 이용하여 예측하였다. 예측된 손상 상태와 시험 데이터와 비교하여 개발된 방법의 적절성을 확인하였다.

Effects of the Nuegra from Male Silkworm Extract on Enhancement of the Masculine Function and Activation of Overall Physical Function

  • Kim, D. C.;Kim, Y. W.;Park, M. S.;J. K. Suh;Lee, D. S.;Lee, S. H.;B. H. Chun;Y. K. Jun
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제5권1호
    • /
    • pp.109-122
    • /
    • 2002
  • The purpose of this investigation is to evaluate the effects of the Nuegra on enhancement of the masculine and physical activities in general through measuring changes of the testosterone, FSH and subjective symptoms like fatigue, insomnia, urinary stream, muscular weakness, libido and erectile dysfunction. Total 168 male subjects were enrolled from 12 urology, internal medicine clinics and general practitioner, During the 6-week investigational period, 2 capsules of Nuegra were given to the subjects right after meal for 4 weeks, and 1 capsule of Nuegra was added each time in subjects with no or minimal effect. Testoster-one and FSH levels were measured at first visit and last visit, for evaluating masculine activities. To avoid bias and standardize the test results, only one clinic was assigned as a central lab, and all blood samples were transferred. General information and subjective symptoms were evaluated at first visit and at 2 weeks interval, week 2, 4 and 6 using VAS (Visual Analogue Scale). The mean age of the subjects were 51.8${\pm}$8.2 years old (range: 36.1-82.1). Based on the subjects who were tested on testosterone and FSH levels at day l and week 6, the means were 4.4${\pm}$1.4 nmol/L (range: 2.6-7.7), 8.6${\pm}$9.6 mIU/mL (range: 0.3-40.4), respectively at day 1. At week 6, the results were 4.9 ${\pm}$1.6 (2.6-8.9 range), 9.4${\pm}$13.1 (1.0-53.9 range), respectively. Marginally significant difference between pre-dose and post-dose was present. Statistically significant differences were revealed in general assessment for subjective symptoms, fatigue, insomnia, erectile dysfunction, etc. In fatigue, response rates were 39.6, 65.4 and 76.4% at week 2, 4 and 6, respectively (P < 0.0001). Response vates for erectile dysfunction were 13.4, 41.2 and 72.7% at week 2, 4, and 6 (P < 0.0001), respectively, Response rates for libido were 13.6, 51.6 and 73.5% at week 2, 4, and 6 (P < 0.0001), respectively. For urinary stream response rates were 26.9, 44.7 and 66.8% at week 2, 4, and 6 (P < 0.0001), respectively. VAS for muscular weakness did not show significant results that response rates were 40, 60 and 80% at week 2, 4, and 6 from 8.2 (P = 0.24), respectively. Response rates for insomnia were 50, 60, 100% at week 2, 4, and 6 (P < 0.0001), respectively. The results shows that Nuegra tends to enhance masculine activities including libido, erectile dysfunction and urinary stream and also effective for improving general conditions especially insomnia, muscular weakness and fatigue. In conclusion, this investigation has demonstrated that Nuegra does not only have tendency to increase masculine activities through increased secretion of the testosterone and FSH but also improve general conditions such as erectile dysfunction, libido, fatigue and muscular power.

링크분석에 의한 우리나라 근해대형트롤선의 선교 레이아웃 개선에 관한 기초연구 (The Basic Study on Improvement Bridge Layout by Link Analysis in Korean Coastal Large Trawler)

  • 김민선;신현옥
    • 수산해양교육연구
    • /
    • 제25권3호
    • /
    • pp.724-732
    • /
    • 2013
  • The purpose of this study is to obtain a basic data on layout of the trawlers' bridge equipment. The task activities of bridge workers involved in the navigation and fishing operation were analyzed by link analysis methods. The results are as follows. It was found that the movement pattern and frequency of bridge workers are different accordance with the bridge work (navigation, casting net, towing net and hauling net). The central workstation of movement of the bridge workers was a radar workstation, a steering workstation and a trawl winch workstation in the bridge work. But the radar did not show up as the center of movement during the hauling net. Workstations related deeply to the central workstations of the movement on the bridge were as below. Radar workstation was related to a GPS plotter, a microphone location for external communication with VHF and MF/HF equipment and a steering in the case of the navigation, the steering, the GPS plotter and the net monitor in the case of the fishing operation. Steering workstation was related deeply to the GPS plotter, the radar in the case of the navigation, a speed controller, the GPS plotter, a fish finder, the net monitor and the microphone location in the case of the fishing operation. Trawl winch workstation showed deep relation with the GPS plotter and the speed control during the fishing operation. Through this study, it was found that Workstations related deeply to the central workstation of the movement of the bridge workers in accordance with the bridge work. The results of this study might be utilized as the basic data on the bridge layout to minimize the fatigue degree due to a physical movement of the bridge workers.

Comparison with Threshold Limit Value (TLV) of Menthol Cigarettes between Expert and Consumer Panel

  • 이승용;이환우;김영호
    • 한국연초학회지
    • /
    • 제28권1호
    • /
    • pp.58-66
    • /
    • 2006
  • Threshold limit value (TLV) test between expert and consumer panel was conducted about absolute, recognition and difference threshold respectively. And we tried to suggest appropriate and minimum acceptable menthol concentration level by consumer panel. Determination of threshold value was based on ASTM E 679-79 method by forced-choice ascending concentration series. In addition, a semi-ascending paired difference method was referred to conduct test. The group threshold value was determined as the value of geometric mean individual threshold. The smokers were dividend by two groups, trained and consumer panel. Trained panel was selected according to sensitivity to menthol discrimination. Consumer panel wasrecruited in proportion as population ratios including female smokers. They were all over twenty years old volunteers and summed up thirty four persons. In terms of sensor evaluation, overall difference test with seven-category scale by both trained and consumer panelists were done. On judging correct or incorrect answer, two by three cut-off levels applied to. Every test was conducted with two sessions, before smoking and during smoking period. And, only two samples served each paneI per test with regard to sensory fatigue and reliable results. All tests were replicated, and in total 32 times per panelist. In conclusion, the recognition threshold about consumer and expert panel was 358 ppm/cig. and 276 ppm/cig. in separately. Besides, absolute and difference thresholds were obtained also. And, we conduct difference threshold test with two different ways, upward and downward. And, The results of each method were 246, 195 ppm/cig., 1414, 1336 ppm/cig. and 1047, 972 ppm/cig.