• 제목/요약/키워드: Center-point error

검색결과 259건 처리시간 0.027초

Siamese Network의 특징맵을 이용한 객체 추적 알고리즘 (Object Tracking Algorithm using Feature Map based on Siamese Network)

  • 임수창;박성욱;김종찬;류창수
    • 한국멀티미디어학회논문지
    • /
    • 제24권6호
    • /
    • pp.796-804
    • /
    • 2021
  • In computer vision, visual tracking method addresses the problem of localizing an specific object in video sequence according to the bounding box. In this paper, we propose a tracking method by introducing the feature correlation comparison into the siamese network to increase its matching identification. We propose a way to compute location of object to improve matching performance by a correlation operation, which locates parts for solving the searching problem. The higher layer in the network can extract a lot of object information. The lower layer has many location information. To reduce error rate of the object center point, we built a siamese network that extracts the distribution and location information of target objects. As a result of the experiment, the average center error rate was less than 25%.

Development of Precise Point Positioning Method Using Global Positioning System Measurements

  • Choi, Byung-Kyu;Back, Jeong-Ho;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권3호
    • /
    • pp.217-223
    • /
    • 2011
  • Precise point positioning (PPP) is increasingly used in several parts such as monitoring of crustal movement and maintaining an international terrestrial reference frame using global positioning system (GPS) measurements. An accuracy of PPP data processing has been increased due to the use of the more precise satellite orbit/clock products. In this study we developed PPP algorithm that utilizes data collected by a GPS receiver. The measurement error modelling including the tropospheric error and the tidal model in data processing was considered to improve the positioning accuracy. The extended Kalman filter has been also employed to estimate the state parameters such as positioning information and float ambiguities. For the verification, we compared our results to other of International GNSS Service analysis center. As a result, the mean errors of the estimated position on the East-West, North-South and Up-Down direction for the five days were 0.9 cm, 0.32 cm, and 1.14 cm in 95% confidence level.

다이아몬드 터닝머신에서 다중점 B 축 제어 가공법을 통한 표면거칠기 향상 (Improvement in Surface Roughness by Multi Point B Axis Control Method in Diamond Turning Machine)

  • 김영복;황연;안중환;김정호;김혜정;김동식
    • 한국정밀공학회지
    • /
    • 제32권11호
    • /
    • pp.983-988
    • /
    • 2015
  • This paper details a new ultra-precise turning method for increasing surface quality, "Multi Point B Axis Control Method." Machined surface error is minimized by the compensation machining process, but the process leaves residual chip marks and surface roughness. This phenomenon is unavoidable in the diamond turning process using existing machining methods. However, Multi Point B axis control uses a small angle (< $1^{\circ}$) for the unused diamond edge for generation of ultra-fine surfaces; no machining chipping occurs. It is achieved by compensated surface profiling via alignment of the tool radial center on the center of the B axis rotation table. Experimental results show that a diamond turned surface using the Multi Point B axis control method achieved P-V $0.1{\mu}m$ and Ra 1.1nm and these ultra-fine surface qualities are reproducible.

시각적 공간분할로 본 Dart 위치의 조형적 설계 (The plastic design of dart location from the viewpoint of visual-spatial division)

  • 정옥임
    • 대한인간공학회지
    • /
    • 제6권1호
    • /
    • pp.33-40
    • /
    • 1987
  • To study the body trunk basic to Clothing construction, and study the peculiarities of visual spatial division, necessary items are measured indirectly from 216 unmarried women from 19 to 24 years old by a photographic net-work method. In so doing, the problem of Fashion Design in establishing the location of Darts for Basic Dress is not considered. The following results are obtained. 1) Indirect measuring method, is obtained approximate to actual size, with an error of .+-. 2.8cm. 2) In the modeling plan of Dart location viewed from the visual-spatial division in Basic Dress, it is concluded that Darts are to be placed at the point of 1/3k+1/5k form the waist. From the aesthetic point of wiew, it is more appealling for darts to be placed at the point of 6cm .+-. 0.6cm right or left of center. 3) From direct measurement dart location can be set based on bust point width, and from indirect measurement, dart location can be set based on waist width.

  • PDF

Accuracy of artificial intelligence-assisted landmark identification in serial lateral cephalograms of Class III patients who underwent orthodontic treatment and two-jaw orthognathic surgery

  • Hong, Mihee;Kim, Inhwan;Cho, Jin-Hyoung;Kang, Kyung-Hwa;Kim, Minji;Kim, Su-Jung;Kim, Yoon-Ji;Sung, Sang-Jin;Kim, Young Ho;Lim, Sung-Hoon;Kim, Namkug;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.287-297
    • /
    • 2022
  • Objective: To investigate the pattern of accuracy change in artificial intelligence-assisted landmark identification (LI) using a convolutional neural network (CNN) algorithm in serial lateral cephalograms (Lat-cephs) of Class III (C-III) patients who underwent two-jaw orthognathic surgery. Methods: A total of 3,188 Lat-cephs of C-III patients were allocated into the training and validation sets (3,004 Lat-cephs of 751 patients) and test set (184 Lat-cephs of 46 patients; subdivided into the genioplasty and non-genioplasty groups, n = 23 per group) for LI. Each C-III patient in the test set had four Lat-cephs: initial (T0), pre-surgery (T1, presence of orthodontic brackets [OBs]), post-surgery (T2, presence of OBs and surgical plates and screws [S-PS]), and debonding (T3, presence of S-PS and fixed retainers [FR]). After mean errors of 20 landmarks between human gold standard and the CNN model were calculated, statistical analysis was performed. Results: The total mean error was 1.17 mm without significant difference among the four time-points (T0, 1.20 mm; T1, 1.14 mm; T2, 1.18 mm; T3, 1.15 mm). In comparison of two time-points ([T0, T1] vs. [T2, T3]), ANS, A point, and B point showed an increase in error (p < 0.01, 0.05, 0.01, respectively), while Mx6D and Md6D showeda decrease in error (all p < 0.01). No difference in errors existed at B point, Pogonion, Menton, Md1C, and Md1R between the genioplasty and non-genioplasty groups. Conclusions: The CNN model can be used for LI in serial Lat-cephs despite the presence of OB, S-PS, FR, genioplasty, and bone remodeling.

MLC 로그 파일 기반 DQA에서 타깃 용적에 따른 영향 연구 (The Study on the Effect of Target Volume in DQA based on MLC log file)

  • 신동진;정동민;조강철;김지훈;윤종원;조정희
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.53-59
    • /
    • 2020
  • 목 적: 본 연구의 목적은 타깃 용적의 변화에 따라 MLC 로그 파일 기반 소프트웨어(Mobius)와 기존의 팬텀-전리함(ArcCheck) 선량 검증 방법 간에 차이를 비교 분석하는데 목적이 있다. 대상 및 방법: 반지름이 0.25cm, 0.5cm, 1cm, 2cm, 3cm, 4cm, 5cm, 6cm, 7cm, 8cm, 9cm, 10cm까지 총 12개의 球(구) 모양 타깃이 있는 플랜을 생성하고 Mobius와 ArcCheck을 사용한 선량 검증을 각각 3번씩 실시하였다. 조사된 데이터를 점선량 오차값과 감마 통과율(3%/3mm)을 평가지표로 하여 비교 분석하였다. 결 과: Mobius의 점선량 오차값은 반지름 0.25cm에서 -9.87%, 0.5cm에서 -4.39%로 나타났고, 나머지 타깃 용적에서 오차값은 3% 이내로 나타났다. 감마 통과율은 반지름 9cm에서 95%, 10cm에서 93.9%로 나타났고, 나머지 타깃 용적에서는 95% 이상의 통과율을 보였다. ArcCheck에서 점선량 평균 오차값은 모든 타깃 용적에서 2% 내외의 일치율을 보였다. 감마 통과율 역시 모든 타깃 용적에서 98% 이상의 통과율을 보였다. 결 론: 반지름 0.5cm 이하의 작은 타깃이나 반지름 9cm 이상의 큰 타깃에서는 MLC 로그 파일 기반 DQA의 불확실성을 고려하여, 팬텀-전리함 기반 DQA를 상호 보완해서 사용함으로써 점선량, 감마 지표, DVH, 타깃 포함 등의 종합적인 분석으로 선량 전달 검증을 하는 것이 바람직하다고 사료된다.

Co60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications

  • Shin, Goo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2065-2069
    • /
    • 2014
  • The DAC-7512E is a 12-bit digital to analog converter that is low power and a single package with internal buffers. The DAC-7512E takes up minimal PCB area for applications of space power electronics design. The spacecraft mass is a crucial point considering spacecraft launch into space. Therefore, we have performed a TID test for the DAC-7512E 12-bit serial input digital to analog converter to reduce the spacecraft mass by using a low-level Gamma-ray irradiator with $Co^{60}$ gamma-ray sources. The irradiation with $Co^{60}$ gamma-rays was carried out at doses from 0 krad to 100 krad to check the error status of the device in terms of current, voltage and bit error status during conversion. The DAC-7512E 12-bit serial digital to analog converter should work properly from 0 krad to 30 krad without any error.

용적조절호형방사선치료(VMAT)의 다중치료중심(Multi- Isocenter)을 이용한 치료 시, 접합부(Junction)의 선량 변화에 대한 고찰 (Examination of Dose Change at the Junction at the Time of Treatment Using Multi-Isocenter Volumetric Modulated Arc Therapy)

  • 정동민;박광순;안혁진;최윤원;박별님;권용재;문성공;이종운;정태식;박령황;김세영;김미정;백종걸;조정희
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.9-14
    • /
    • 2021
  • 용적조절호형방사선치료(Volumetric Modulated Arc Therapy)의 다중치료중심(Multi-Isocenter)을 이용하여 치료 시, 접합부(Junction)의 재현 오차에 따른 선량변화에 대해 고찰하였다. Arccheck Phantom에 임의의 치료부위를 설정하고, 다중치료중심에 대해 치료계획을 수립하였다. 그리고 X(왼쪽), Y(위쪽), Z(안쪽, 바깥쪽) 방향에 대해서 접합부의 오차를 0 ~ 4 mm로 설정 후 선형가속기를 이용하여 방사선을 조사하였고, 이 후 phantom을 통해 얻어진 점 선량(point dose)과 감마인덱스(gamma Index)를 통해 분석하였다. X방향과 Y방향에 대한 오차가 2, 4 mm 발생 했을 때, 감마패스율(점 선량)은 각각 99.3% (2.085), 98% (2.079 Gy) 와 98.5% (2.088), 95.5% (2.093 Gy)로 나타났다. 그리고 Z방향에 대해서 안쪽과 바깥쪽에 대한 오차가 1, 2, 4 mm 발생 했을 때, 감마패스율(점 선량)은 각각 94.8% (2.131), 82.6% (2.164), 72.8% (2.22 Gy) 와 93.4% (2.069), 90.6% (2.047), 79.7% (1.962 Gy) 로 보여졌다. X, Y방향에 대해서 4 mm 까지의 오차 결과는 허용오차 안에 있었으나, Z방향에 대해서는 1 mm 를 초과하는 오차 값에 대해서 허용오차 밖의 결과 값이 도출되었다. 이는 높은 선량 영역(high dose area)과 낮은 선량 영역(low dose area)에 대해 치료부위의 진행방향과 같은 방향의 오차가 선량 분포(dose distribution)가 더 민감하다는 것을 시사한다. 향후 지속적인 연구를 통해 기관차원의 셋 업(set up) 오차에 대한 가이드라인이 정립된다면, 접합부를 이용한 치료에서 양질의 치료를 제공할 수 있을 것이라 사료된다.

RGB 영상에서 딥러닝 기반 동공 중심점을 이용한 홍채 검출 (Iris Localization using the Pupil Center Point based on Deep Learning in RGB Images)

  • 이태균;유장희
    • 한국소프트웨어감정평가학회 논문지
    • /
    • 제16권2호
    • /
    • pp.135-142
    • /
    • 2020
  • 본 논문에서는 RGB 영상에서 홍채 검출 방법에 관하여 기술하였다. 기존의 홍채 검출 방법은 대부분 적외선 영상을 대상으로 하고 있어, 다양한 응용을 위해서는 RGB 영상의 홍채 검출 기술이 요구된다. 제안된 홍채 검출 방법은 i) 입력 영상에서 원형 허프 변환을 사용한 홍채 후보 영역 검출, ii) 딥러닝 기반의 동공 중심점 검출, iii) 동공 중심점을 이용한 홍채 영역 선택, iv) 선택된 홍채 영역 보정 과정으로 구성된다. 홍채 후보 영역은 허프 공간을 생성한 후 중심점 후보의 교차 개수가 많은 순으로 검출하며, 후보 영역 중 홍채는 검출된 동공의 중심점을 기준으로 선택한다. 그리고, 홍채의 모양이 왜곡되어 오차가 발생하는 것을 보완하기 위해 검출된 홍채 중심을 기준으로 새로운 경계점을 찾아 보정하는 방법을 사용하였다. 또한, 실험을 통하여 제안된 방법이 기존 원형 허프 변환 방법 대비 약 27.4% 향상된 정확도를 갖는 것을 확인하였다.

대규모 그리드 접지전극의 과도접지임피던스의 측정 (The transient grounding impedance measurment of large grid grounding electrodes)

  • 전병욱;이수봉;이봉;이승주;정동철;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF