• Title/Summary/Keyword: Center of Pressure (CoP)

Search Result 134, Processing Time 0.029 seconds

Correlation between motor performance and displacements of center of pressure in hemiplegic patients (편마비 환자의 운동수행능력과 질량중심 변화의 상관 관계)

  • Lee, Ilsuk;Lim, Hyungmoon;Choi, Sanho;Oh, Jaegun;Sung, Kang-keyng;Lee, Sangkwan
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2013
  • ■ Objectives The aim of this study is to look into the correlation between motor performance and displacement of center of pressure(CoP) in hemiplegic patients with cerebral stroke. ■ Methods We measured manual muscle test(MMT) as motor performance value and, anterior/posterior position(Ant./Post. position) and lateral symmetry of CoP as displacement of CoP values from 129 stroke patients. The gait analysis was carried out using treadmill gait analysis equipment. ■ Results In terms of motor performance, MMT of upper extremity negatively correlated with Ant/Post position of CoP, however, one of lower extremity did not. In addition, MMT of both extremities negatively correlated with lateral symmetry of CoP. ■ Conclusion Displacement of CoP was negatively correlated with hemiplegic patient's motor performance.

  • PDF

Correlation Analysis between Postural Sway and Kinematics Variables of Putter Head during Golf Putting (골프 퍼팅 시 자세 흔들림과 퍼터 헤드의 운동학적 변인 간 상관성 분석)

  • Lee, Jae-Woo;Kwon, Moon-Seok;Park, Jun-Sung;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.3
    • /
    • pp.217-223
    • /
    • 2020
  • Objective: The purpose of this study was to analyze the effect of postural sway on the kinematic variables of the putter head during golf putting and to provide information to the importance of postural sway control in the putting stroke for novice golfers. Method: The center of pressure (CoP) and Kinematics variables of the putter head were calculated during 2 m flat golf putting using 8 motion capture cameras (250 Hz) and 2 force plate (1,000 Hz). SPSS 24.0 was used to perform Pearson's correlation coefficient and simple regression analysis, and the statistically significance level was set to .05. Results: As a result of analyzing the correlation between CoP variables and the putter head rotation angle, the CoP moving length, CoP moving range (ML direction), and CoP moving velocity (ML direction) showed a positive correlation with the putter head rotation angle (yaw axis) and were statistically significant. Conclusion: Therefore, In order to perform the accurate putting stroke maintaining the ball's directionality, it is determined that it is important to control posture sway in the ML directions by minimizing the movement and velocity of the CoP.

Development of Plantar Pressure Measurement System and Personal Classification Study based on Plantar Pressure Image

  • Ho, Jong Gab;Kim, Dae Gyeom;Kim, Young;Jang, Seung-wan;Min, Se Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.11
    • /
    • pp.3875-3891
    • /
    • 2021
  • In this study, a Velostat pressure sensor was manufactured to develop a plantar pressure measurement system and a C#-based application was developed to monitor and collect plantar pressure data in real time. In order to evaluate the characteristics of the proposed plantar pressure measurement system, the accuracy of plantar pressure index and personal classification was verified by comparing with MatScan, a commercial plantar pressure measurement system. As a result, the output characteristics according to the weight of the Velostat pressure sensor were evaluated and a trend line with the reliability of r2 = 0.98 was detected. The Root Mean Square Error(RMSE) of the weighted area was 11.315 cm2, the RMSE of the x coordinate of Center of Pressure(CoPx) was 1.036 cm and the RMSE of the y coordinate of Center of Pressure(CoPy) was 0.936 cm. Finally, inaccuracy of personal classification, the proposed system was 99.47% and MatScan was 96.86%. Based on the advantage of being simple to implement and capable of manufacturing at low cost, it is considered that it can be applied to various fields of measuring vital signs such as sitting posture and breathing in addition to the plantar pressure measurement system.

Effect of Pressure Rise Time on Tidal Volume and Gas Exchange During Pressure Control Ventilation (압력조절환기법에서 압력상승시간(Pressure Rise Time)이 흡기 일환기량 및 가스교환에 미치는 영향)

  • Jeoung, Byung-O;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Lim, Chae-Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.766-772
    • /
    • 2000
  • Background : Pressure rise time (PRT) is the time in which the ventilator aclieves the set airway pressure in pressure-targeted modes, such as pressure control ventilation (PCV). With varying PRT, in principle, the peak inspiratory flow rate of the ventilator also varies. And if PRT is set to a shorter duration, the effective duration of target pressure level would be prolonged, which in turn would increase inspiratory tidal volume(Vti) and mean airway pressure (Pmean). We also postulated that the increase in Vti with shortening of PRT may relate inversely to the patients' basal airway resistance. Methods : In 13 paralyzed patients on PCV (pressure control 18$\pm$9.5 cm $H_2O$ $FIO_2\;0.6\pm0.3$, PEEP 5$\pm$3 cm $H_2O$, f 20/min, I : E1 : 2) with Servo 300 (Siemens-Elema, Solna, Sweden) from various causes of respiratory failure, PRT of 10 %, 5 % and 0 % were randomly applied. At 30 min of each PRT trial, peak inspiratory flow (PIF, L/sec), Vti (ml), Pmean (cm $H_2O$) and ABGA were determined. Results : At PRT 10%, 5%, and 0%, PIF were 0.69$\pm$0.13, 0.77$\pm$0.19, 0.83$\pm$0.22, respectively (p<0.001). Vti were 425$\pm$94, 439$\pm$101, 456$\pm$106, respectively (p<0.001), and Pmean were 11.2$\pm$3.7, 12.0$\pm$3.7, 12.5$\pm$3.8, respectively (p<0.001). pH were 7.40$\pm$0.08, 7.40$\pm$0.92, 7.41$\pm$0.96, respectively (p=0.00) ; $PaCO_2$ (mm Hg) were 47.4$\pm$15.8, 47.2 $\pm$15.7, 44.6$\pm$16.2, respectively (p=0.004) ; $PAO_2-PaO_2$ (mm Hg) were 220$\pm$98, 224$\pm$95, 227$\pm$94, respectively (p=0.004) ; and $V_n/V_T$ as determined by ($PaCO_2-P_E-CO_2$)/$PaCO_2$ were 0.67$\pm$0.07, 0.67$\pm$0.08, 0.66$\pm$0.08, respectively (p=0.007). The correlation between airway resistance and change of Vti from PRT 10% to 0% were r= -0.243 (p=0.498). Conclusion : Shortening of pressure rise timee during PCV was associated with increased tidal volume, increased mean airway pressure and lower $PaCO_2$.

  • PDF

Trajectory Estimation of Center of Plantar Foot Pressure Using Gaussian Process Regression (가우시안 프로세스 회귀를 이용한 족저압 중심 궤적 추정)

  • Choi, Yuna;Lee, Daehun;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.3
    • /
    • pp.296-302
    • /
    • 2022
  • This paper proposes a center of plantar foot pressure (CoP) trajectory estimation method based on Gaussian process regression, with the aim to show robust results regardless of the regions and numbers of FSRs of the insole sensor. This method can bring an interpolation between the measurement points inside the wearable insole sensor, and two experiments are conducted for performance evaluation. For this purpose, the input data used in the experiment are generated in three types (13 FSRs, 8 FSRs, 5 FSRs) according to the regions and numbers of FSRs. First, the estimation results of the CoP trajectory are compared using Gaussian process regression and weighted mean. As a result of each method, the estimation results of the two methods were similar in the case of 13 FSRs data. On the other hand, in the case of the 8 and 5 FSRs data, the weighted mean varies depending on the regions and numbers of FSRs, but the estimation results of Gaussian process regression showed similar results in spite of reducing the regions and numbers. Second, the estimation results of the CoP trajectory based on Gaussian process regression during several gait cycles are analyzed. In five gait cycles, the previous cycle and the current estimation results are compared, and it was confirmed that similar trajectories appeared in all. In this way, the method of estimating the CoP trajectory based on Gaussian process regression showed robust results, and stability was confirmed by yielding similar results in several gait cycles.

The Effect of the Plantar Pressure on Dynamic Balance by Fatigue of Leg in the Subjects with Functional Ankle Instability (기능적 발목 불안정성시 하지 근피로에 의한 동적균형이 족저압에 미치는 영향)

  • Kim, Ho-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.734-742
    • /
    • 2016
  • Purpose : The present study was aimed at investigating the plantar pressure on dynamic balance of subjects with functional ankle instability following fatigue of lower leg. Methods : The subjects(30 university students) were divided into 2 groups ; functional ankle instability group(7males and 7females) and ankle stable group(9males & 7females) who could evaluate questionnaire. All the participants were evaluated muscle fatigue of lower leg by Biodex system III and distribution of plantar pressure by Zebris FDM-S system, The dynamic balance was tested by single-leg jump landing. This study were to measure of plantar pressure on dynamic balance with the difference between FAIG and control group following muscle fatigue. Results : In functional ankle instability group(FAIG), the post-fatigue was significantly higher than pre-fatigue in forefoot(p2,p3,p4) of plantar pressure on dynamic balance(p<0.05). The FAIG was significantly higher than the ASG in forefoot(p2, p3, p4) & lat midfoot(p6) of plantar pressure after fatigue in dynamic balance(p<0.05). The FAIG was significantly longer than the ASG in anteroposterior(AP) & mediolateral(ML) distance on center of pressure(CoP) after fatigue in dynamic balance(p<0.05). Conclusion : This study showed that FAIG were effected plantar pressure and center of pressure(CoP) by dynamic balance following muscle fatigue. Further study is needed to measure various age & work with ankle instability for clinical application.

Relationship between Center of Pressure and Local Stability of the Lower Joints during Walking in the Elderly Women

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • Objective: The purpose of this study was to determine the relationship between center of pressure (CoP) and local stability of the lower joints, which was calculated based on approximate entropy (ApEn) during walking in elderly women. Method: Eighteen elderly women were recruited (age: $66.4{\pm}1.2yrs$; mass: $55.4{\pm}8.3kg$; height: $1.56{\pm}0.04m$) for this study. Before collecting data, reflective marker triads composed of 3 non-collinear spheres were attached to the lateral surface of the thigh and shank near the mid-segment to measure motion of the thigh and shank segments. To measure foot motion, reflective markers were placed on the shoe at the heel, head of the fifth metatarsal, and lateral malleolus, and were also placed on the right anterior-superior iliac spine, left anterior-superior iliac spine, and sacrum to observe pelvic motion. During treadmill walking, kinematic data were recorded using 6 infrared cameras (Oqus 300, Qualisys, Sweden) with a 100 Hz sampling frequency and kinetic data were collected from a treadmill (Instrumented Treadmill, Bertec, USA) for 20 strides. From kinematic data, 3D angles of the lower extremity's joint were calculated using Cardan technique and then ApEn were computed for their angles to evaluate local stability. Range of CoP was determined from the kinetic data. Pearson product-moment and Spearman rank correlation coefficient were applied to find relationship between CoP and ApEn. The level of significance was determined at p<.05. Results: There was a negative linear correlation between CoP and ApEn of hip joint adduction-abduction motion (p<.05), but ApEn of other joint motion did not affect the CoP. Conclusion: It was conjectured that ApEn, local stability index, for adduction/abduction of the hip joint during walking could be useful as a fall predictor.

The effect of abrasive size and shape on W CMP (W CMP 공정에서 abrasive size 와 shape 영향성)

  • Park, Joon-Sang;Park, Jung-Hun;Lee, Jae-Dong;Hong, Chang-Ki;Cho, Han-Ku;Moon, Joo-Tae;Ryu, Byoung-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.243-246
    • /
    • 2004
  • W CMP 공정에서 abrasive 의 size 및 shape 에 따른 CMP 거동에 대해 관찰하였으며, 주요 제거 막질인 W 막질과 stopping layer 로 사용되는 Oxide 막질에 대한 압력(P)과 상대 속도(V) 영향성을 관찰하였다. CMP 제거량이 입자의 size 변화에 의존한다는 기존의 이론과는 달리 응집도(aggregate ratio) 변화가 주요 변수임을 밝혀 내었다. 한편, 각 막질에 대한 P,V 영향성 평가를 통해, 변형된 Prestonian equation 이 abrasive size 및 shape 에 상관없이 W 막질의 제거 거동을 설명하는데 중요한 역할을 수행함을 보였다. 그렇지만, W CMP 공정에서 stopping layer 로 사용되는 oxide 막질의 거동을 설명하는 데에는 어려움이 있었으며, 특히 P,V 에 의한 비선형적 removal rate(RR) 거동발생으로 인해 기존의 이론치와는 많은 차이를 나타내었다. 또한, abrasive size 와 shape 에 따라서도 복잡한 거동을 나타낸다.

  • PDF

Physicochemical Properties of Bistrifluron, Benzoylphenylurea Insecticide (Benzoylphenylurea 계 살충제 Bistrfluron의 물리화학적 특성)

  • Kim, Kyun;Chang, Hee-Ra;Yang, Kyu-Wan;Jeong, Bong-Jin;Kim, Yong-Hwa
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.3
    • /
    • pp.254-258
    • /
    • 2007
  • Several physicochemical properties including water solubility, vapor pressure, and hydrolysis of bistrifluron benzoylphenylurea insecticide developed in Korea, were measured based on OECD guidelines for testing of chemicals and Toxic Substances Control Act Test guidelines. Water solubility was low showing 30 ${\mu}g/l$ at $25^{\circ}C$ and in hydrolysis study, half-life at $20^{\circ}C$ was 10.9 days (pH 9.0) and was stable in pH 7.0 solution. At $40^{\circ}C$ hydrolysis rate was 20.6 days (pH 7.0) and 1.5 days (pH 9.0). The vapor pressure of bistrifluron was not obtained from vapor pressure experiments at $25^{\circ}C$ because the bistrifluron was not detected. Therefore, the vapor pressure was determined to be ${\leq}\;2.05{\times}10^{-8}$ torr which was calculated to apply the detection limit (50 ng) of bistrifluron. And this value is suggests it would not give environmental contamination by volatilization.

Analysis of Bale Surface Pressure According to Stretch Film Layer Changes on Round Bale Wrapping

  • Hong, Sungha;Kang, Daein;Kim, Daeyeon;Lee, Sangsik
    • Journal of Biosystems Engineering
    • /
    • v.42 no.3
    • /
    • pp.136-146
    • /
    • 2017
  • Purpose: This paper presents an appropriate wrapping method by analyzing the pressure distribution applied to a bale surface, along with the change in pressure according to an increase in the number of film layers in rice straw bales, which account for 74% of the total bulky feed supply in Korea. Methods: A model with the shape of an actual bale was fabricated to analyze the distribution of surface pressure in bale wrapping, and the pressure was measured. Experiments were conducted to analyze the pressure using eight different layer numbers (2, 4, 6, 8 10, 12, 14, and 16 layers) at five wrapping speeds (27, 29, 31, 33, and 35 rpm). Results: The maximum pressure applied to a circular bale by the film occurred at the center of the end of the bale, whereas the minimum pressure occurred at the center of the bale side. An extreme value ratio between the minimum and maximum pressures was distributed as 8.5-56.6%, which was improved with an increase in rotation speed. The an uneven pressure distribution occurred because the number of film overlaps was 8.24-times greater at the center of the bale's end than at the center of the ba le side. At a level 5 rotation speed, the minimum pressure was $P_{LV5-M1}=0.0625{\sigma}^2+36.173{\sigma}-36.753$ ($R^2=0.9845$) at $M_1$, and the maximum pressure was $P_{LV5-M6}=5.5552{\sigma}^2+41.05{\sigma}-39.071$ at $M_2$, revealing a correlation of $R^2=0.9983$. Conclusions: To replace four layers with six layers, 2-4 layers were added only to the side of the bale, and the minimum pressure at $M_1$ was then improved from that at four layers to that at six layers, and the amount of film consumed for 4-6 layers was reduced by 84.6%.