• Title/Summary/Keyword: Center of Mass (CoM)

Search Result 126, Processing Time 0.029 seconds

Effects of Skill and Distance Factors on Center of Mass and Center of Pressure during Golf Putting (골프 퍼팅 시 숙련도와 거리 요인이 신체 무게 중심과 압력 중심에 미치는 영향)

  • Park, JunSung;Lim, Young-Tae;Lee, JaeWoo;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.4
    • /
    • pp.205-211
    • /
    • 2019
  • Objective: The purpose of this study was to analyze the effects of skill and distance factors on CoP (Center of pressure) and CoM (Center of mass) during golf putting. Method: 38 golfers were participated in this study. 8 motion capture cameras (250 Hz) and 2 force plates (1,000 Hz) were used to collect CoP and CoM during 2 m and 3 m of distance golf putting. To identify main effect and interaction effect, it was performed Two-Way ANOVA at a significant level of a .05. Results: In the novice group, CoP distance was significantly difference in the A/P direction and main effect between skill level and distance. Both groups indicated that CoP distance was significantly different and main effect between skill level and distance in the M/L direction. Finally, both groups showed that CoM was significantly different and main effect between skill level and distance in the M/L direction. Conclusion: Therefore, novice golfers are expected to be able to perform more accurate and proper putting exercise through the practice of minimizing the center of mass(CoM) and center of pressure (CoP) in the M/L direction, which is the pendulum movement of the putter head.

Real-Time CoM/ZMP Trajectory Transformation Method for Humanoid Robots Considering Structure Characteristics (구조 특성을 반영한 인간형 로봇을 위한 실시간 CoM/ZMP 궤적 변환 방법)

  • Hong, Seok-Min
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.132-137
    • /
    • 2017
  • This paper proposes a transformation method of the zero moment point (ZMP) and the center of mass (CoM) from one walking pattern to other patterns by considering the structure of a robot or walking situations in real time. In general, a humanoid robot has own structure characteristics like height and mass. The structure characteristics make the given CoM/ZMP walking pattern of one human or one humanoid robot to be difficult to apply to other robot directly. For this purpose, we analyze the characteristics of walking patterns according to the step length, duration of walking support phase and the CoM height by using the cart-table model as the simple humanoid robot model. A transformation equation is derived from the analyzation and it is verified with simulation.

On the Estimation of the Center of Mass of an Autonomous Bipedal Robot (이족보행 로봇의 무게중심 실시간 추정에 관한 연구)

  • Kwon, Sang-Joo;Oh, Yong-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.9
    • /
    • pp.886-892
    • /
    • 2008
  • In this paper, a closed-loop observer to extract the center of mass (CoM) of a bipedal robot is suggested. Comparing with the simple conversion method of just using joint angle measurements, it enables to get more reliable estimates by fusing both joint angle measurements and F/T sensor outputs at ankle joints. First, a nonlinear-type observer is constructed to estimate the flexible rotational motion of the biped in the extended Kalman filter framework. It adopts the flexible inverted pendulum model which is appropriate to address the flexible motion of bipeds, specifically in the single support phase. The predicted estimates of CoM in terms of the flexible motion observer are combined with measurements (that is, output of the CoM conversion equation with joint angles). Then, we have final CoM estimates depending on the weighting values which penalize the flexible motion model and the CoM conversion equation. Simulation results show the effectiveness of the proposed algorithm.

Evaluation of Gait Stability using Medio-Lateral Inclination Angle in Male Adults (좌·우 기울기각도를 이용한 남자 성인의 보행안정성 평가)

  • Chang, Jae-Kwan;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.261-266
    • /
    • 2010
  • Human body is hard to be in perfect balance during walking. Most of time the trunk is supported by one leg and the center of mass(COM) falls to the contralateral side. Thus, dynamic variables such as the velocity of the COM should be considered when gait stability is evaluated. The purpose of this study was to investigate whether the extrapolated center of mass(XCom) which utilized the COM position and its velocity, is appropriate to evaluate gait stability. Ten healthy adults participated in this study and performed 3 different types of gaits(normal(NG), hands on waists(HWG), and hands on shoulders(HSG)) onto 4 different types of obstacle(obstacle height: 0%, 30%, 40% and 50% of leg length). Medio-lateral Com-CoP and XCom-CoP inclination angle were calculated during support phase. For all condition, greater M-L XCoM-CoP inclination angles were found(p<.05) compared with those of matched obstacle height CoM-CoP. Especially, M-L XCoM-CoP inclination angle at 50% height revealed the best condition for monitoring dynamic stability. Significantly increased in M-L XCoM-CoP inclination angle was found(p<.05) as obstacle height increased on NG and HWG.

Properties of Acetyl-CoA Synthetase from Pseudomonas fluorescens

  • Kim, Yu-Sam;An, Jae-Hyung;Yang, Bu-Hyun;Kim, Kyu-Wan
    • BMB Reports
    • /
    • v.29 no.4
    • /
    • pp.277-285
    • /
    • 1996
  • In Pseudomonas fluorescens grown on malonate as sole carbon source, acetyl-CoA synthetase was induced, suggesting that malonate is metabolized through acetate and then acetyl-CoA. Acetyl-CoA synthetase was purified 18.6-fold in 4 steps to apparent homogeneity. The native molecular mass of the enzyme estimated by a native acrylamide gel electrophoresis was 130 kDa. The enzyme was composed of two identical subunits with a molecular mass of 67 kDa. Optimum pH was 70. The acetyl-CoA synthetase showed typical Michaelis-Menten kinetics for the substrates, acetate, ATP and CoA, whose $K_m$ values were calculated to be 33.4, 74.8, and 40.7 mM respectively. Propionate. butyrate and pentanoate were also used as substrates by the enzyme, but the rate of the formation of the CoA derivatives was decreased in the order of the increase in carbon number. The enzyme was inhibited by the group-specific reagents diethylpyro-carbonate, 2,3-butanedione, pyridoxal-5'-phosphate and N-bromosuccinimide. In the presence of substrates the inactivation rate of the enzyme, by all of the group-specific reagents mentioned above decreased, indicating the presence of catalytically essential histidine, arginine, lysine and tryptophan residues at or near the active site. Preincubation of the enzyme with ATP, $Mg^{2+}$ resulted in the increase of its susceptibility to diethylpyrocarbonate, suggesting that ATP, $Mg^{2+}$ may induce a conformational change in the active site exposing the essential histidine residue to diethylpyrocarbonate. The enzyme was acetylated in the presence of acetyl-CoA, indicating that this is one of acyl-enzyme.

  • PDF

Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma

  • Kong, Tae Yeon;Ji, Hye Young;Choi, Sang-Zin;Son, Miwon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.55-58
    • /
    • 2013
  • Dioscin is a biologically active steroidal saponin with anticancer and hepatoprotective effects. A rapid, selective, and sensitive liquid chromatographic method with electrospray ionization tandem mass spectrometry was developed for the quantification of dioscin in rat plasma. Dioscin was extracted from rat plasma using ethyl acetate at acidic pH. The analytes were separated on a Halo C18 column using gradient elution of acetonitrile and 0.1% formic acid and detected by tandem mass spectrometry in selected reaction monitoring mode. The standard curve was linear ($r^2$ = 0.998) over the concentration range of 1-100 ng/mL. The lower limit of quantification was 1.0 ng/mL using 50 ${\mu}L$ of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.3 to 8.0% and -5.4 to 10.0%, respectively. This method was applied successfully to the pharmacokinetic study of dioscin after oral administration of dioscin at a dose of 29.2 mg/kg in male Sprague-Dawley rats.

Center of Mass Compliance Control of Humanoid Using Disturbance Observer (외란 관측기를 이용한 휴머노이드 무게 중심 유연 동작 제어)

  • Park, Gyeongjae;Kim, Myeong-Ju;Park, Jaeheung
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.3
    • /
    • pp.339-346
    • /
    • 2022
  • To operate in real environment, humanoid robots should be able to react to unknown disturbances. To deal with disturbances, various robust control algorithms have been developed for decades. But for collaborative works such as teleoperation system, a compliance control can be the better solution for disturbance reactions. In this paper, a center of mass (CoM) compliance control algorithm for humanoid robots is proposed. The proposed algorithm is based on the state observer and positive feedback of disturbance. With the state observer based on humanoid CoM control performance model, disturbance in each direction can be observed. The positive feedback of disturbances to the reference CoM trajectory enables compliant motion. The main contributions of this algorithm are achieving compliance independently in each axis and maintaining balance against external force. Through dynamic simulations, the performance of the proposed method was demonstrated. Under two types of disturbance conditions, humanoid robot DYROS-JET reacted with compliant motion via the proposed algorithm.

Rational Design of Binder-Free Fe-Doped CuCo(OH)2 Nanosheets for High-Performance Water Oxidation

  • Patil, Komal;Jang, Su Young;Kim, Jin Hyeok
    • Korean Journal of Materials Research
    • /
    • v.32 no.5
    • /
    • pp.237-242
    • /
    • 2022
  • Designing and producing a low-cost, high-current-density electrode with good electrocatalytic activity for the oxygen evolution reaction (OER) is still a major challenge for the industrial hydrogen energy economy. In this study, nanostructured Fe-doped CuCo(OH)2 was discovered to be a precedent electrocatalyst for OER with low overpotential, low Tafel slope, good durability, and high electrochemically active surface sites at reduced mass loadings. Fe-doped CuCo(OH)2 nanosheets are made using a hydrothermal synthesis process. These nanosheets are clumped together to form a highly open hierarchical structure. When used as an electrocatalyst, the Fe-doped CuCo(OH)2 nanosheets required an overpotential of 260 mV to reach a current density of 50 mA cm-2. Also, it showed a small Tafel slope of 72.9 mV dec-1, and superior stability while catalyzing the generation of O2 continuously for 20 hours. The Fe-doped CuCo(OH)2 was found to have a large number of active sites which provide hierarchical and stable transfer routes for both electrolyte ions and electrons, resulting in exceptional OER performance.

Observation of Co-Existing Copepods in the Marine Rotifer Mass Culture Tanks (해산 로티퍼 대량 배양 수조에서 관찰되는 코페포다의 혼재 양상)

  • Jung, Min-Min;Kim, Hyowon;Hur, Jun Wook;Kim, Jung;Kang, Kyoung Ho
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.9 no.2
    • /
    • pp.30-34
    • /
    • 2017
  • Microorganisms are contained filtered sea water that is why we often observed co-existing copepod species in the large-scale rotifer culture tanks. In this study, we investigated about taxonomical study of co-existing copepods in Brachionus rotifer mass culture tanks of several seafarming centers at Jeju-do and Pusan, Korea by microscope. Also, we counted number of copeods and density in 10 mL of cultured sea water and distinguished growing patterns and sex. As results, we can identified 4 species copepods, 2 species of Tisbe, 1 species of Tigriopus and 1 species of Apocyclops.

Effect of Auditory Stimulus using White Nosie on Dynamic Balance in Patients with Chronic Stroke during Walking

  • Lim, Hee Sung;Ryu, Jiseon;Ryu, Sihyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.4
    • /
    • pp.301-309
    • /
    • 2020
  • Objective: This study aimed to investigate the effect of white noise on dynamic balance in patients with stroke during walking. Method: Nineteen patients with chronic stroke (age: 61.2±9.8 years, height: 164.4±7.4 cm, weight: 61.1±9.4 kg, paretic side (R/L): 11/8, duration: 11.6±4.9 years) were included as study participants. Auditory stimulus used white noise, and all participants listened for 40 minutes mixing six types of natural sounds with random sounds. The dynamic balancing ability was evaluated while all participants walked before and after listening to white noise. The variables were the center of pressure (CoP), the center of mass (CoM), CoP-CoM inclined angle. Results: There is a significant increase in the antero-posterior (A-P) CoP range, A-P inclination angle, and gait speed on the paretic and non-paretic sides following white noise intervention (p<.05). Conclusion: Our findings confirmed the positive effect of using white noise as auditory stimulus through a more objective and quantitative assessment using CoP-CoM inclination angle as an evaluation indicator for assessing dynamic balance in patients with chronic stroke. The A-P and M-L inclination angle can be employed as a useful indicator for evaluating other exercise programs and intervention methods for functional enhancement of patients with chronic stroke in terms of their effects on dynamic balance and effectiveness.