• Title/Summary/Keyword: Center Fire

Search Result 988, Processing Time 0.028 seconds

Quantitative Fire Risk Assesment for the Subway Platform Types (지하철 승강장 형식에 따른 정량적 화재 위험성 평가)

  • Rie, Dong-Ho;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.

Correlation Study between the Changes of the Fire- and Heat- Related Symptoms and Motor Function Recovery in Acute Cerebral Infarction Patients (급성기 뇌경색 환자의 화열증상 변화와 기능회복도간의 상관관계에 대한 연구)

  • Hyun, Sang-Ho;Min, Kyung-Dong;Yei, Young-Chul;Kang, Ah-Reum;Lee, Eun-Chan;Moon, Sang-Kwan;Cho, Ki-Ho;Jung, Woo-Sang;Park, Sung-Wook;Ko, Chang-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.4
    • /
    • pp.428-437
    • /
    • 2013
  • Objectives : The aim of this study was to examine if there is a significant correlation between the changes of Fire- and Heat- related symptoms and motor function recovery in acute cerebral infarction patients. Methods : We studied inpatients within a month after the onset of cerebral infarction who were admitted at Kyunghee University Medical Center from May 2011 to January 2013. We executed correlation analysis between Fire-heat pattern score and motricity index score at visit 1 and visit 2, and checked if there was a significant correlation between the changes of Fire-heat pattern score and changes of motricity index score. Also, we compared the changes of both scores in patients taking Fire-heat and non Fire-heat pattern prescriptions. Results : There was a significant correlation between the Fire-heat pattern score and Motricity index score at visit 1 and visit 2, and changes of Fire-heat pattern score showed significant correlation with changes of motricity index score. Patients taking Fire-heat pattern prescriptions showed significant change in Fire-heat pattern score after herb-medication treatment while patients taking non-Fire-heat prescriptions showed insignificant change in Fire-heat pattern score. Conclusions : This study provides evidence that taking a Fire-heat pattern prescription could be considered as a first line herb-medication treatment in acute cerebral infarction patients.

The change in temperature·humidity·perspiration of fire suit when applying phased intensive exercises to fire fighter wearing fire suit (소방공무원의 방화복 착용 후 단계별 운동강도 변화 시 의복 내 온도·습도·발한량 차이)

  • Choi, Seo-Yeon;Park, Il-Gyu;Kong, Il-Chean;Rie, Dong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.97-103
    • /
    • 2013
  • The purpose of this study was to verify the change in temperature humidity perspiration of fire suit when applying phased intensive exercises to fire fighter wearing fire suit. For this study, three male fire fighters took basic physical test and performed 10 minute phased intensive exercises -exercise intensity I (30%VO2max), exercise intensity II (45%VO2max), exercise intensity III (60%VO2max) based on maximum oxygen consumption (VO2max)- wearing fire suit (helmet, boots, air respirator) in treadmill and took a rest. The result of study shows that the temperature in the suit elevated during stabilization period after each exercise intensity, humidity elevated as exercise intensity increased, perspiration elevated as exercise intensity increased. This study indirectly ascertained the fire suit's physiological change in fire fighters during field activities.

A Study on the Fire Resistance Performance Concerning Types of Fire Protection Method and Load Ratio of High Strength Concrete Column Using The Wire Rope (와이어로프를 적용한 고강도 철근콘크리트 기둥의 내화공법 및 하중비에 따른 내화성능에 관한 연구)

  • Cho, Bum-Yean;Yeo, In-Hwan;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.64-71
    • /
    • 2012
  • The fire resistance test has been conducted under the standard fire & loading conditions to evaluate fire resistance performance, according to applying to methods of the lateral confinement reinforcement by prestressed Wire Rope and fire resistance reinforcement by Fiber-Cocktail and load ratio for high strength concrete column. The test result, for 60 MPa high-strength concrete column, It was indicated that applying to the wire rope has improved axial ductility in the fire condition, and fire resistance performance has been enhanced by more than 23 %. In addition to this, in case of applying the wire rope to 60 MPa high-strength concrete column, load can be judged that about 70 % of designed load is appropriate. If the Wire Rope and Fiber-Cocktail is applied to 100 MPa high-strength concrete column, It was shown that the fire resistance performance was enhanced by 4 times as much as applying only hoops.

Cancer Perceptions Among Smokeless Tobacco Users: A Qualitative Study of US Firefighters

  • Jitnarin, Nattinee;Poston, Walker S.C.;Jahnke, Sara A.;Haddock, Christopher K.;Kelley, Hannah N.
    • Safety and Health at Work
    • /
    • v.11 no.3
    • /
    • pp.284-290
    • /
    • 2020
  • Background: Prevalence rates of smokeless tobacco (SLT) use among firefighters are remarkably high and substantially higher than similar occupational groups and the general U.S. population. The purpose of this study was to explore the perspectives of fire service personnel regarding cancer and its associations with tobacco and SLT use. Methods: This descriptive study used a qualitative approach. Key informant interviews were conducted in 39 career firefighters and fire service administration from across the U.S. Discussion were recorded, transcribed verbatim and transferred to NVivo software for narrative analysis. Topics explored included cancer perceptions, attitudes and beliefs, and cultural factors related to SLT use behaviors. Results: Major themes that emerged among fire service personnel included concerns about cancer and its risk factors including firefighting tasks, such as fire overhaul operations, and from their lifestyle behaviors, such as alcohol and tobacco use. Firefighters also suggested a number of reasons for their increased SLT use, such as fire department tobacco-free policy and fire service culture. Conclusion: The current study provides a rich foundation for future research, prevention, and intervention efforts for the fire service and research communities regarding tobacco and SLT use and cancer risk. Additional research on firefighters' cancer beliefs deserves future research in order to improve messaging about the risks of cancer due to firefighting.

An Experimental Study of Smoke Movement of the Various Fire Location in Room (실내공간에서 화재 발생위치에 따른 연기거동에 대한 실험연구)

  • Yu, Hong-Seon;Jeong, Jin-Yong;Lee, Jae-Ha;Hong, Gi-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.703-709
    • /
    • 2002
  • In order to investigate the smoke movement in three dimensional room fires, the center fire, wall fire and corner fire plume in different sized fires were studied experimentally by rectangular pool fire using methanol as a fuel. As the fire size became larger for the center fires placed at the center of the floor, the air flow rate entrained through the opening, average hot layer temperature, flame angle deflected backwards and mean flame height was observed to increase. On the other hand, as the fire size became smaller, the neutral plane height in the door and time reached steady-state was observed to decrease. The average hot layer temperature, mean flame height and doorway neutral plane height obtained from comer fire were higher than those produced by wall fires and center fires. The simple model for describing the effect of walls on the mean flame height was presented. It was shown that the model provides a good description of the present measurements, when used with the assumption by Hansell(1993), that the increase of the average flame height is equal to the ratio of the open to the total perimeters of the trays. Also the two models for predicting the effects of walls on the mean flame height were presented. These models overestimated the measured values of the mean flame height above fuel trays close to a wall and in a corner by approximately 19-26%, respectively.

Norms about Alcohol Use among US Firefighters

  • Christopher K. Haddock;Nattinee Jitnarin;Raul Caetano;Sara A. Jahnke;Brittany S. Hollerbach;Christopher M. Kaipust;Walker S.C. Poston
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.387-393
    • /
    • 2022
  • Background: Problem drinking is a perennial concern in the US fire service. A large literature has documented the importance of addressing alcohol norms in intervention research. The purpose of this study was to explore alcohol norms in a national cohort of firefighters (FFs) to inform intervention development in this occupational group. Methods: Data were from a national online survey of career and volunteer FFs (N = 674). Participants were recruited through national fire service listservs and a database of FFs who had agreed to be contacted for research. Results: When asked about "acceptable" levels of alcohol consumption, FFs on average suggested levels which exceeded public health guidelines. Further, approximately half of career and volunteer FFs believed that, at least under some circumstances, drinking until intoxicated was normative. When asked how long should elapse between a FFs last drink and reporting for duty, the average suggested lag was 11.2 hours (sd = 4.6). However, among male volunteer FFs who reported heavy drinking, the average was 6.68 hours (sd = 4.77). Conclusions: Given the high prevalence of heavy and binge drinking in the fire service, it is not surprising that the alcohol norms found in this study were consistent with a culture of drinking. Participants' reports of alcohol use among their peers were consistent with the actual prevalence of problem drinking. Thus, education and prevention efforts in this occupation should focus on changing norms about alcohol use, including linking heavy drinking to other health and safety issues they face.

A Study on Characteristics of Smoke Release for Structural Adhesives (건축외장용 접착제의 발연 특성에 관한 연구)

  • Lee, Hae-Pyeong;Park, Young-Ju;Hwang, Me-Jung;Lee, Won-Seok;Yang, Young-Suk;Lee, Mi-Li
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.453-456
    • /
    • 2011
  • 본 연구에서는 건축외장용 접착제의 발연특성을 알아보기 위해 접착제를 용도별로 구분하여 연기밀도시험기를 이용해 최대연기밀도와 초기발생연기밀도를 알아보았다. 실험 결과 창호전용 접착제가 586초에 509.64로 가장 많은 연기밀도를 발생하였으며, 석재용 275.63, 목공용 232.25의 순으로 많은 양의 연기가 발생하였고, 타일용 18.65, 스티로폼용 6.44로 최대연기밀도를 나타내었다. 창호전용과 스티로폼용의 경우 최대연기밀도를 나타낸 시간은 비슷한 범위에 나타났으나 연기밀도 값은 스티로폼용에 비해 창호전용 접착제가 80배 가까이 연기가 더 발생하는 것을 알 수 있었다.

  • PDF

A Study on Combustion Gas Toxicity of Architecture Surface Material (건축용 외장재의 연소가스 독성평가)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hae-Rim;Lee, Won-Seok;Yang, Young-Suk;Lee, Mi-Li
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.441-446
    • /
    • 2011
  • 본 연구에서는 건축물에 화재가 발생 시, 건축용 외장재로부터 발생하는 연소가스의 독성을 분석함으로써 소방관을 비롯한 건물 재실자들에게 미치는 영향에 대해서 고찰하였다. 실험 방법은 건물의 외장재로 많이 사용되는 일반스티로폼, 강화스티로폼, 우레탄폼 그리고 유리섬유 재질의 외장재를 대상으로 NES 713 방법을 이용하였다. 실험 결과를 살펴보면, 대부분의 시료들로부터 CO, $CO_2$, HCHO, $CH_2CHCN$, $NO_x$ 등이 검출되었으며, 우레판폼의 경우, 다른 시료들과 달리 HCl과 HCN이 추가적으로 검출되었다. 하지만 대부분의 시료들로부터 검출된 독성가스들은 치사농도에는 훨씬 못미치는 것으로 나타났으며, 독성지수 값들을 살펴보면, 일반스티로폼<강화스티로폼<유리섬유<우레판폼의 순으로 나타났다.

  • PDF