• Title/Summary/Keyword: Cemented abutment

Search Result 63, Processing Time 0.022 seconds

THE EFFECT OF CYCLIC LOADING ON THE RETENTIVE STRENGTH OF FULL VENEER CROWNS (반복 하중이 Full veneer crown의 유지력에 미치는 영향에 관한 연구)

  • Kim, Ki-Youn;Lee, Sun-Hyung;Chung, Hun-Young;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.583-594
    • /
    • 2000
  • Dislodgement of a crown or extension bridge and the loosening of a retainer of a bridge is a serious clinical problem in fixed restoration. Generally these problems are considered to be associated with deformation of the restoration. During biting, the restoration is subjected to complex forces and deforms considerably within the limit of its elasticity. Deformation of the restoration under the occlusal force induces excessive stress in the cement film, which then leads to the cement fracture. Such a fracture may eventually cause loss of the restoration. Because most of the past retention tests for full veneer crown were done without fatigue loading, they were not exactly simulating intraoral environment. And the purpose of this study was to evaluate the effect of cyclic cantilever loading on the retentive strength of full veneer crowns depending on different type of cements and taper of prepared abutment. Steel dies with $8^{\circ}\;or\;16^{\circ}$ convergence angle were fabricated through milling and crowns with the same method. These dies and crowns were divided into 8 groups. Group 1 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 2 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 3 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 4 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 5 : $16^{\circ}$ taper die, cementation with Panavia 21, without loading Group 6 : $16^{\circ}$ taper die, cementation with Panavia 21, with loading Group 7 : $8^{\circ}$ taper die, cementation with Panavia 21 without loading Group 8 : $8^{\circ}$ taper die, cementation with Panavia 21, with loading After checking the fit of die and crown, the luting surface of dies and inner surface of crowns were air-abraded for 10 seconds. The crowns were cemented to the dies, with cements mixed according to the manufacturer's recommendations. A static load of 5kg was then applied for 10 minutes with static loading device. Twenty-four hours later, group 1, 3, 5, 7 were only thermocycled, group 2, 4, 6, 8 were subjected to cyclic loading after thermocycling. Retentive tests were performed on the Instron machine. From the finding of this study, the following conclusions were obtained 1. Panavia 21 showed significantly higher retentive strength than zinc phosphate cement for all groups (p<0.05). 2. There was a significant difference in the retentive strength between $8^{\circ}\;and\;16^{\circ}$ taper for zinc phosphate cement(p<0.05), but no significant difference for Panavia 21 (p>0.05). 3. Cyclic loading significantly decreased the retentive strength for all groups(p<0.05). 4. For zinc phosphate cement, there was 35% reduction of the retentive strength after loading in the $16^{\circ}$ taper die, 25% in the $8^{\circ}$ taper die, and for Panavia 21, 21% in the $16^{\circ}$ taper die, 18% in the $8^{\circ}$ taper die.

  • PDF

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.

Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations (두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교)

  • Shin, Ho-Sik;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.528-534
    • /
    • 2008
  • Purpose: Marginal fit is one of the important components for the successful prosthodontic restoration. Poor fitting margin of the restoration causes hypersensitivity, secondary caries, and plaque accumulation, which later result in prosthodontic failure. CAD/CAM zirconia all-ceramic restorations, such as $LAVA^{(R)}$ (3M ESPE, St.Paul, MN) and $EVEREST^{(R)}$ (KaVo Dental GmbH, Biberach, Germany) systems were recently introduced in Korea. It is clinically meaningful to evaluate the changes of the marginal fit of the CAD/CAM zirconia systems before and after build-up. The purposes of this study are to compare the marginal fit of the two CAD/CAM all-ceramic systems with that of the ceramometal restoration, before and after porcelain build-up Material and methods: A maxillary first premolar dentiform tooth was prepared with 2.0 mm occlusal reduction, 1.0 mm axial reduction, chamfer margin, and 6 degree taperness in the axial wall. The prepared dentiform die was duplicated into the metal abutment die. The metal die was placed in the dental study model, and the full arch impressions of the model were made. Twenty four copings of 3 groups which were $LAVA^{(R)}$, $EVEREST^{(R)}$, and ceramometal restorations were fabricated. Each coping was cemented on the metal die with color-mixed Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan). The marginal opening of each coping was measured with $Microhiscope^{(R)}$ system (HIROX KH-1000 ING-Plus, Seoul, Korea. X300 magnification). After porcelain build-up, the marginal openings of $LAVA^{(R)}$, $EVEREST^{(R)}$,and ceramometal restorations were also evaluated in the same method. Statistical analysis was done with paired t-test and one-way ANOVA test. Results: In coping states, the mean marginal opening for $EVEREST^{(R)}$ restorations was $52.00{\pm}11.94\;{\mu}m$ for $LAVA^{(R)}$ restorations $56.97{\pm}10.00\;{\mu}m$, and for ceramometal restorations $97.38{\pm}18.54\;{\mu}m$. After porcelain build-up, the mean marginal opening for $EVEREST^{(R)}$ restorations was $61.69{\pm}19.33\;{\mu}m$, for $LAVA^{(R)}$ restorations $70.81{\pm}12.99\;{\mu}m$, and for ceramometal restorations $1115.25{\pm}23.86\;{\mu}m$. Conclusion: 1. $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations in comparison with ceramometal restorations showed better marginal fit, which had significant differences (P < 0.05) in coping state and also after porcelain build-up . 2. The mean marginal opening values between $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations did not showed significant differences after porcelain build-up as well as in coping state (P > .05). 3. $EVEREST^{(R)}$, $LAVA^{(R)}$ and ceramometal restorations showed a little increased marginal opening after porcelain build-up, but did not show any statistical significance (P > .05).