• Title/Summary/Keyword: Cell-based sensor

Search Result 186, Processing Time 0.025 seconds

Recent Technology Trends and Future Prospects for Image Sensor (이미지 센서의 최근 기술 동향과 향후 전망)

  • Park, Sangsik;Shin, Bhumjae;Uh, Hyungsoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • The technology and market size of image sensors continue to develop thanks to the release of image sensors that exceed 100 million pixels in 2019 and expansion of black box camera markets for vehicles in addition to existing mobile applications. We review the technology flow of image sensors that have been constantly evolving for 40 years since Hitachi launched a 200,000-pixel image sensor in 1979. Although CCD has made inroads into image sensor market for a while based on good picture quality, CMOS image sensor (CIS) with active pixels has made inroads into the market as semiconductor technology continues to develop, since the electrons generated by the incident light are converted to the electric signals in the pixel, and the power consumption is low. CIS image sensors with superior characteristics such as high resolution, high sensitivity, low power consumption, low noise and vivid color continue to be released as the new technologies are incorporated. At present, new types of structures such as Backside Illumination and Isolation Cell have been adopted, with better sensitivity and high S/N ratio. In the future, new photoconductive materials are expected to be adopted as a light absorption part in place of the pn junction.

Model-based Fault Detection Method for the Air Supply System of a Residential PEM Fuel Cell (가정용 고분자전해질 연료전지 공기공급시스템의 모델 기반 고장 검출 기술)

  • WON, JINYEON;KIM, MINJIN;LEE, WON-YONG;CHOI, YOON-YOUNG;HONG, JONG SUP;OH, HWANYEONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.556-566
    • /
    • 2019
  • Recently, as the supply of residential polymer electrolyte membrane fuel cells (PEMFCs) increases, the durability and lifetime of the PEMFC system are becoming important. The related studies have been mainly focused on the durability and lifetime of materials while the research on the durability and maintenance of the system level is insufficient. In this paper, a model-based fault detection method is developed considering an air supply system that is dominant to the system performance and efficiency. A commercial 1 kW residential fuel cell system is built, and experiments are conducted under various operation loads and states (normal, 6 faults). From the experimental data, nominal models and residuals are generated. With the residual pattern obtained from real-time data, the detection and classification of various faults can be possible. The technical importance of this paper is to minimize extra sensor installation by using the empirical model rather than a complex mathematical model, and to decrease the number of models by using the applicable model at three loads. Finally, the model-based fault detection method for the air supply system of a PEMFC is established and is expected to be applicable to other subsystems.

The Design of Intelligent Human Cell Management System with RFID (RFID와 연계한 인체자원관리 시스템 설계)

  • Kim, Ki-Bong
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.311-316
    • /
    • 2013
  • In order to maximize an efficient management of human cell resource under the cryogenic environments, in this paper, a middleware is introduced to support the function for multiple-perceiving RFID tags of intelligent sample case which can share medical information between sensor network devices. Optimized user interface is also designed for that. On based of the designing, special tasks required of a genetic resource working process can be processed on Complex Machine.

Effects of Temperature and Humidity on NDIR CO2 Gas Sensor (비분산 적외선 이산화탄소 가스센서 특성의 온·습도 영향)

  • Kim, JinHo;Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.179-185
    • /
    • 2017
  • This article describes the characteristics of nondispersive infrared carbon dioxide gas sensor according to the temperatures and humidifies. In this researches, a thermopile sensor that included application-specific integrated circuit (ASIC) was used and the White-cell structure was implemented as an optical waveguide. The developed sensor modules were installed in gas chamber and then the temperature of gas chamber has been increased from 283 K to 313 K with 10K temperature step. In order to analyze the effects of humidity levels, the relative humidity levels were changed from 30 to 80%R.H. with small humidifier. Then, the characteristics of sensor modules were acquired with the increment of carbon dioxide concentrations from 0 to 2,000 ppm. When the initial voltages of sensors were compared before and after humidifying the chamber at constant temperature, the decrements of the output voltages of sensors are like these: 9mV (reference infrared sensor), 41 mV (carbon dioxide sensor), 2 mV (temperature sensor). With the increment of ambient temperature, the averaged output voltage of carbon dioxide sensor was increased 19 mV, however, when the humidity level was increased, it was decreased 14mV. Based upon the experimental results, the humidity effect could be alleviated by the increment of temperature, so the effects of humidity and temperature could be only compensated by the ambient temperature itself. The estimated carbon dioxide concentrations showed 10% large errors below 200 ppm, however, the errors of the estimations of carbon dioxide concentrations were less than ${\pm}5%$ from 400 to 2,000 ppm.

Forklift Weight Measurement System using Anchor Bolt Type Strain Gauge Sensor (Anchor 볼트 형태의 Strain Gauge 센서를 이용한 지게차 적재 중량 측정 시스템)

  • Han, Chi-moon;Yim, Choon-Sik;Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.200-206
    • /
    • 2019
  • The most frequent type of safety-accident in industry is the overturning of forklift. The leading cause of this accident is overload in forklift. Thus, it is needed to measure the weight on board of forklift. The most common method is based on load cell, and this method has the merit of high accuracy. However, high price is the disadvantage of this method. In this paper, we propose the new measurement system of the weight on board of forklift based on the strain gauge sensor, which has the disadvantage of low accuracy. The differentiation of the proposed system is that the shape of the strain gauge sensor customized for anchor bolt of forklift in order to improve the accuracy and durability. In system four strain gauge sensors are inserted into four anchor bolts. The test result shows that 1% error of measurement is obtained in the proposed anchor bolt type strain gauge sensors.

Improvement of Cathode Reaction of a Mediatorless Microbial Fuel Cell

  • Pham, The-Hai;Jang, Jae-Kyung;Chang, In-Seop;Kim, Byung-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.324-329
    • /
    • 2004
  • Oxygen diffuses through the cation-specific membrane, reducing the coulomb yield of the fuel cell. In the present study, attempts were made to enhance current generation from the fuel cell by lowering the oxygen diffusion, including the uses of ferricyanide as a cathode mediator and of a platinum-coated graphite electrode. Ferricyanide did not act as a mediator as expected, but as an oxidant in the cathode compartment of the microbial fuel cell. The microbial fuel cell with platinum-coated graphite cathode generated a maximum current 3-4 times higher than the control fuel cell with graphite cathode, and the critical oxygen concentration of the former was 2.0 mg $1^{-1}$, whilst that of the latter was 6.6 mg $1^{-1}$. Based on these results, it was concluded that inexpensive electrodes are adequate for the construction of an economically feasible microbial fuel cell with better performance as a novel wastewater treatment process.

Force Transmission in Cellular Adherens Junction Visualized by Engineered FRET Alpha-catenin Sensor (형광공명에너지전이 알파카테닌 센서를 활용한 세포 부착접합부에서의 힘 전달 이미징)

  • Jang, Yoon-Kwan;Suh, Jung-Soo;Suk, Myungeun;Kim, Tae-Jin
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.366-372
    • /
    • 2021
  • Cadherin-Catenin complex is thought to play an essential role in the transmission of force at adherens junction. Due to the lack of proper tools to visualize and detect mechanical force signals, the underlying mechanism by which the cadherin-catenin complex regulates force transmission at intercellular junctions remains elusive. In this study, we visualize cadherin-mediated force transmission using an engineered α-Catenin sensor based on fluorescence resonance energy transfer. Our results reveal that α-catenin is a key force transducer in cadherin-mediated mechanotransduction at cell-cell junctions. Thus, our finding will provide important insights for studying the effects of chemical and physical signals on cell-cell communication and the relationship between physiological and pathological phenomena.

A Comparison of System Performances Between Rectangular and Polar Exponential Grid Imaging System (POLAR EXPONENTIAL GRID와 장방형격자 영상시스템의 영상분해도 및 영상처리능력 비교)

  • Jae Kwon Eem
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.2
    • /
    • pp.69-79
    • /
    • 1994
  • The conventional machine vision system which has uniform rectangular grid requires tremendous amount of computation for processing and analysing an image especially in 2-D image transfermations such as scaling, rotation and 3-D reconvery problem typical in robot application environment. In this study, the imaging system with nonuiformly distributed image sensors simulating human visual system, referred to as Ploar Exponential Grid(PEG), is compared with the existing conventional uniform rectangular grid system in terms of image resolution and computational complexity. By mimicking the geometric structure of the PEG sensor cell, we obtained PEG-like images using computer simulation. With the images obtained from the simulation, image resolution of the two systems are compared and some basic image processing tasks such as image scaling and rotation are implemented based on the PEG sensor system to examine its performance. Furthermore Fourier transform of PEG image is described and implemented in image analysis point of view. Also, the range and heading-angle measurement errors usually encountered in 3-D coordinates recovery with stereo camera system are claculated based on the PEG sensor system and compared with those obtained from the uniform rectangular grid system. In fact, the PEC imaging system not only reduces the computational requirements but also has scale and rotational invariance property in Fourier spectrum. Hence the PEG system has more suitable image coordinate system for image scaling, rotation, and image recognition problem. The range and heading-angle measurement errors with PEG system are less than those of uniform rectangular rectangular grid system in practical measurement range.

  • PDF

SOx Sensor Using NASICON Solid Electrolyte (NASICON 고체 전해질을 사용한 SOx 가스 감지센서)

  • Choi, Soon-Don;Lee, Kwang-Beum
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.25-34
    • /
    • 1996
  • A SOx sensor using NASICON electrolyte was developed for monitoring of air pollution. The following galvanic cell with $Na_{2}SiO_{3}(Pt)$ reference electrode was assembled : Pt | $Na_{2}SiO_{3}$ | NASICON | $Na_{2}SO_{4}$ | Pt, $SO_{2}$, air $Na_{2}SO_{4}$ was used as an indicator electrode to protect NASICON electrolytes from chemical reaction with $SO_{2}$. The EMFs were measured after injecting $SO_{2}$ in the initial concentrations range of $5{\sim}95ppm$ at $400{\sim}550^{\circ}C$. The measured and calculated potentials were in good agreement above $500^{\circ}C$. However, the cells were unstable below $500^{\circ}C$, most likely due to incomplete attainment of chemical equilibrium. Response time was within 10 min. Based on the stability and response time of this cell, the NASICON solid electrolyte with $Na_{2}SiO_{3}(Pt)$ as the reference electrode and $Na_{2}SO_{4}$ (Pt)as the indicator electrode showed the possibility of a reliable, inexpensive commercial solid-state SOx sensor.

  • PDF

Implementation of IoT Application using Geofencing Technology for Mountain Management (산악 관리를 위한 지오펜싱 기술을 이용한 IoT 응용 구현)

  • Hyeok-jun Kweon;Eun-Gyu An;Hoon Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.3
    • /
    • pp.300-305
    • /
    • 2023
  • In this paper, we confirmed that an efficient sensor network can be established at a low cost by applying Geofencing technology to a LoRa-based sensor network and verified its effectiveness in disaster management such as forest fires. We detected changes through GPS, gyro sensors, and combustion detection sensors, and defined the validity size of the Geofencing cell accurately. We proposed a LoRa Payload Frame Structure that has a flexible size according to the size of the sensor information.