• 제목/요약/키워드: Cell size model

검색결과 382건 처리시간 0.023초

원통형 전기집진기의 전기유체역학적 해석에 관한 연구 (Study on Electrohydrodynamic Analysis of Cylinder Type ESP)

  • 조용수;여석준
    • 한국대기환경학회지
    • /
    • 제12권3호
    • /
    • pp.243-254
    • /
    • 1996
  • The main purpose of this study is to investigate the collection efficiency characteristics of a cylindrical ESP. To do that, it is necessary to analyze the electric field, gas flow field, and mechanism of particle movement by numerical simulation based on EHD model. For a gas flow field, Navier-Stokes equation involving the electric source term was solved by SIMPLE algorithm. In case of the electric field, the current continuity and electric field equations were solved by S.O.R. method. The analysis of particle movement was performed on the basis of PSI-CELL model from the Lagrangian viewpoint. The results showed that the influence on the gas flow field by the electric field is almost negligible in a cylindrical ESP. The particle drift velocity $V_P$ toward the collection surface is increased continuously by the electrostatic force due to the rise of particle charge as the particle is moving to the flow direction and the particle size becomes larger. The collection efficiency is to quitely higher with the increase of applied voltage for the same particle size, while becomes smaller as the inlet velocity is increased.

  • PDF

가스 제트 모델을 이용한 DME 분무 해석의 격자 의존성 저감 (Reduction of Grid Size Dependency in DME Spray Modeling with Gas-jet Model)

  • 오윤중;김사엽;이창식;박성욱
    • 한국분무공학회지
    • /
    • 제15권4호
    • /
    • pp.170-176
    • /
    • 2010
  • This paper describes the grid-size dependency of the conventional Eulerian-Lagrangian method to spray characteristics such as spray penetration and SMD in modeling DME sprays. In addition, the reduction of the grid-size dependency of the present Gas-jet model was investigated. The calculations were performed using the KIVA code and the calculated results were compared to those of experimental result. The results showed that the conventional Eulerian-Laglangian model predicts shorter spray penetration for large cell because of inaccurate calculation of momentum exchange between liquid and gas phase. However, it was shown that the gas-jet model reduced grid-size dependency to spray penetration by calculating relative velocity between liquid and ambient gas based on gas jet velocity.

레이더 자료의 해상도를 고려한 분포형 강우-유출 모형의 GIS 자료 최적 격자의 결정 (Decision of GIS Optimum Grid on Applying Distributed Rainfall-Runoff Model with Radar Resolution)

  • 김연수;장권희;김병식;김형수
    • 한국습지학회지
    • /
    • 제13권1호
    • /
    • pp.105-116
    • /
    • 2011
  • 최근 몇 년간 기후변화에 의해 기상이변이 발생하고 있으며 이에 따른 집중호우로 인한 홍수피해가 심각하게 증가하고 있다. 이러한 피해를 저감하기 위한 수문기상학적 요소와 특성인자들의 정확한 상호 연관성 규명과 공간적 변동성 해석은 강우-유출 모형에서 발생하는 불확실성을 감소시키는데 중요한 요소로 작용하게 된다. 이에 본 연구에서는 레이더강우 격자 해상도와 지형인자 격자 해상도에 따라 강우-유출모형이 어떻게 반응하는지 분석하였으며, 가-분포 강우-유출 모형인 ModClark 모형을 이용하여 강원도 인제군의 내린천 유역을 대상으로 광덕산 레이더자료를 이용하였다. ModClark 모형 구성을 위한 GIS 지형공간 자료는 30m, 150m, 250m, 350m 격자크기의 DEM을 사용하였으며, 2006년 7월 14일부터 7월 17일까지의 관측레이더 강우자료를 500m, 1km, 2km, 5km, 10km 사용하여 유출모의를 실시하고, 각각의 격자해상도에 따른 모의 결과를 비교하기 위해 유출 수문곡선을 작성하고 유출량 변화를 모의하였다. 분석 결과 첨두유량 및 유출체적에 대해서는 DEM 30m~150m, 레이더강우 500m~2km 크기의 격자일 때 가장 최적의 유출 모의를 한 것으로 분석되었으며, 통계적 분석에 의한 분석결과에서는 모든 DEM 격자는 레이더강우 격자가 500m인 경우, 모든 레이더강우 격자는 DEM 30m인 경우에 모형의 적합성이 높은 것으로 나타났고, 민감도 산정 결과 지수 등급이 높은 DEM이 분포형 모형의 결과 값에 큰 영향을 주는 것으로 분석되었다. 최근 집중형 모형에서 분포형 모형을 이용한 강우-유출해석이 이루어지고 있기에 모델링 구성을 위한 효율적인 의사결정의 기준으로 활용될 수 있을 것으로 기대된다.

GIS를 이용한 CN 산정에 관한 연구 (A Study on the Computation of Curve Number Using GIS)

  • 조용재;박상주;정인주;김상용
    • 대한공간정보학회지
    • /
    • 제11권3호
    • /
    • pp.47-53
    • /
    • 2003
  • 격자크기에 따른 경사도 분석과 소유역에 대하여 축척별 격자크기(cell size)가 수문인자 결정에 어떠한 영향을 미치는지 연구하고자, 본 연구에서는 수영강 유역의 토지이용도 및 토양도를 분류 선정한 후 GIS를 이용하여 CN을 계산하고, 이 값을 이용하여 수영강 유역의 유출모형을 분석하는데 요구되는 수문학적 지형인자의 결정에 기초자료로 활용하고자 한다. 각 격자크기에 따라 CN을 산정한 결과, 본 연구에서는 격자크기가 $100m{\times}100m$인 경우 가장 최적인 것으로 나타났다.

  • PDF

Effect of particle size on direct shear deformation of soil

  • Gu, Renguo;Fang, Yingguang;Jiang, Quan;Li, Bo;Feng, Deluan
    • Geomechanics and Engineering
    • /
    • 제28권2호
    • /
    • pp.135-143
    • /
    • 2022
  • Soils are natural granular materials whose mechanical properties differ according to the size and composition of the particles, so soils exhibit an obvious scale effect. Traditional soil mechanics is based on continuum mechanics, which can not reflect the impact of particle size on soil mechanics. On that basis, a matrix-reinforcing-particle cell model is established in which the reinforcing particles are larger-diameter sand particles and the matrix comprises smaller-diameter bentonite particles. Since these two types of particles deform differently under shear stress, a new shear-strength theory under direct shear that considers the stress concentration and bypass phenomena of the matrix is established. In order to verify the rationality of this theory, a series of direct shear tests with different reinforcing particle diameter and volume fraction ratio are carried out. Theoretical analysis and experimental results showed that the interaction among particles of differing size and composition is the basic reason for the size effect of soils. Furthermore, the stress concentration and bypass phenomena of the matrix enhance the shear strength of a soil, and the volume ratio of reinforcing particles has an obvious impact on the shear strength. In addition, the newly proposed shear-strength theory agrees well with experimental values.

EFDC 모형을 이용한 댐 붕괴류 수치모의 및 매개변수 민감도 분석 (Numerical Simulation of Dam Break Flow using EFDC Model and Parameter Sensitivity Analysis)

  • 장철;송창근
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.143-149
    • /
    • 2016
  • In this study, a series of numerical simulation of dam break flow was conducted using EFDC model, and input conditions including cell size, time step, and turbulent eddy viscosity were considered to analyze parameter sensitivity. In case of coarse mesh layout, the propagated length of the shock wave front was ${\Delta}_x$ longer than that of other mesh layouts, and the velocity results showed jagged edge, which can be cured by applying fine grid mesh. Turbulent eddy viscosity influenced magnitude of the maximum velocity passing through gate up to 20% and the cell Peclet number less than 2.0 ensured no numerical oscillations.

유전 알고리즘에 기초한 제조셀의 설계 (Design of Manufacturing Cell based on Genetic Algorithm)

  • 조규갑;이병욱
    • 한국정밀공학회지
    • /
    • 제15권12호
    • /
    • pp.72-80
    • /
    • 1998
  • In this study, a design approach based on genetic algorithm is proposed to solve the manufacturing cell design problem considering alternative process plans and alternative machines. The problem is formulated as a 0-1 integer programming model which considers several manufacturing parameters, such as demand and processing time of part, machine capacity, manufacturing cell size, and the number of machines in a machine cell. A genetic algorithm is used to determine process plan for each part, part family and machine cell simultaneously.

  • PDF

The history and regulatory mechanism of the Hippo pathway

  • Kim, Wantae;Jho, Eek-hoon
    • BMB Reports
    • /
    • 제51권3호
    • /
    • pp.106-118
    • /
    • 2018
  • How the organ size is adjusted to the proper size during development and how organs know that they reach the original size during regeneration remain long-standing questions. Based on studies using multiple model organisms and approaches for over 20 years, a consensus has been established that the Hippo pathway plays crucial roles in controlling organ size and maintaining tissue homeostasis. Given the significance of these processes, the dysregulation of the Hippo pathway has also implicated various diseases, such as tissue degeneration and cancer. By regulating the downstream transcriptional coactivators YAP and TAZ, the Hippo pathway coordinates cell proliferation and apoptosis in response to a variety of signals including cell contact inhibition, polarity, mechanical sensation and soluble factors. Since the core components and their functions of the Hippo pathway are evolutionarily conserved, this pathway serves as a global regulator of organ size control. Therefore, further investigation of the regulatory mechanisms will provide physiological insights to better understand tissue homeostasis. In this review, the historical developments and current understandings of the regulatory mechanism of Hippo signaling pathway are discussed.

하천의 프랙탈 특성을 이용한 합성단위유량도의 개발 (Development of Synthetic Unit Hydrograph using River Fractal Characteristics)

  • 차상화
    • 한국농공학회지
    • /
    • 제44권6호
    • /
    • pp.61-70
    • /
    • 2002
  • This study was performed to analyze the river fractal characteristics using GIS (Geographic Information System). In this study, topographical factors in river basin were grid-analyzed for each cell size and scale using GIS and regression formula was derived by analyzing correlation among topographical factors and cell size which were calculated here. And, a new rainfall-runoff model which is considering the calculated fractal dimension was developed to apply fur a river basin.

수치고도모형을 이용한 본류하천길이에 관한 프랙탈 차원의 해석 (The Analysis of Fractal Dimension on the Main-Stream Length using Digital Elevation Model)

  • 차상화
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.915-923
    • /
    • 2002
  • Recently, GIS(Geographic Information System) is used to extract various hydrological factors from DEM(Digital Elevation Model) in river basin. Therefore, this study aims at the determination of river fractal dimension using DEM. In this paper, the main-stream length in river basin was grid-analyzed for each scale(1/5,000, 1/25,000, 1/50,000) and each cell size(5m$\times$5m, l0m$\times$l0m, 20m$\times$20m, 30m$\times$30m, 40m$\times$40m, 50m$\times$50m, 60m$\times$60m, 70m$\times$70m, 80m$\times$80m, 90m$\times$90m, 100m$\times$l00m, 120m$\times$120m, 150m$\times$150m) using GIS. Also, fractal dimension was derived by analyzing correlation among main-stream lengths, scale, and cell size which were calculated here. The result of calculating fractal dimension for each cell size shows that the fractal dimension on the main-stream length is 1.028.