• 제목/요약/키워드: Cell diffusion

검색결과 889건 처리시간 0.029초

열처리 슬러리코팅법을 이용한 연료전지 가스확산층의 제조 (Fabrication of Gas Diffusion Layer for Fuel Cells Using Heat treatment Slurry Coating Method)

  • 김성진;박성범;박용일
    • 열처리공학회지
    • /
    • 제25권2호
    • /
    • pp.65-73
    • /
    • 2012
  • The Gas Diffusion Layer (GDL) of fuel cell, are required to provide both delivery of reactant gases to the catalyst layer and removal of water in either vapor or liquid form in typical PEMFCs. In this study, the fabrication of GDL containing Micro Porous Layer (MPL) made of the slurry of PVDF mixed with carbon black is investigated in detail. Physical properties of GDL containing MPL, such as electrical resistance, gas permeability and microstructure were examined, and the performance of the cell using developed GDL with MPL was evaluated. The results show that MPL with PVDF binder demonstrated uniformly distributed microstructure without large cracks and pores, which resulted in better electrical conductivity. The fuel cell performance test demonstrates that the developed GDL with MPL has a great potential due to enhanced mass transport property due to its porous structure and small pore size.

왕복 유동을 통한 확산증대 효과가 연료전지 성능에 미치는 영향에 대한 수치해석 (Numerical Simulation of the Oscillating Flow Effect in the Channel of Polymer Electrolyte Membrane Fuel Cell)

  • 김종민;강경식
    • 대한안전경영과학회지
    • /
    • 제20권4호
    • /
    • pp.7-13
    • /
    • 2018
  • This study investigates the enhancement of the oxygen diffusion rate in the cathode channel of a proton exchange membrane fuel cell (PEMFC) by pure oscillating flow, which is the same as the mechanism of human breathe. Three-dimensional numerical simulation, which has the full model of the fuel cell including electrochemical reaction, ion and electronic conduction, mass transfer and thermal variation and so on, is performed to show the phenomena in the channel at the case of a steady state. This model could analysis the oscillating flow as a moving mesh calculation coupled with electrochemical reaction on the catalyst layer, however, it needs a lot of calculation time for each case. The two dimensional numerical simulation has carried on for the study of oscillating flow effect in the cathode channel of PEMFC in order to reduce the calculation time. This study shows the diffusion rate of the oxygen increased and the emission rate of the water vapor increased in the channel by oscillating flow without any forced flow.

물-시멘트비와 재령이 콘크리트의 염소이온 확산특성에 미치는 영향 (Effect of Water-Cement Ratio and Aging on the Characteristics of Chloride Ions Diffusion in Concrete)

  • 배수호;정영수;김진영;하재담;심은철;임병탁
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.737-742
    • /
    • 2002
  • The chief factors for the penetration and diffusion of chloride ions in concrete are water-cement ratio(w/c), aging, thickness of cover concrete, chloride ions concentration of given environment, wet and dry conditions and etc. In this study, effect of w/c and aging on the characteristics of chloride ions diffusion in concrete were researched when environmental factors for the penetration and diffusion of chloride ions were constant. For this purpose, the voltages passing through the diffusion cell were measured by using accelerated test method using potential difference, and then diffusion coefficients of chloride ions by using Andrade's method were estimated for 44%, 49.5% and 55% of w/c, respectively. As a result, correlation among diffusion coefficients of chloride ions, w/c and aging were concluded through multiple regression model.

  • PDF

콘크리트의 염소이온 확산특성에 미치는 양생조건의 영향 (Effect of Curing Conditions on the Characteristics of Chloride Ion Diffusion in Concrete)

  • 임병탁;배수호;정영수;심은철;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.715-720
    • /
    • 2003
  • The chief factors for the penetration and diffusion of chloride ions in concrete are water-cement ratio(W/C), aging, curing conditions, chloride ions concentration of given environment., wet and dry conditions and etc. In this study, of these factors effect of curing conditions such as standard and outdoor curing on the characteristics of chloride ions diffusion in concrete were researched when environmental factors for the penetration and diffusion of chloride ions were constant. For this purpose, the voltages passing through the diffusion cell were measured by using accelerated test method using potential difference, and then diffusion coefficients of chloride ions by using Andrade's method were estimated for 44%, 49.5% and 60% of w/c, respectively. As a result., according to curing conditions correlation among diffusion coefficients of chloride ions, W/C and aging were concluded through multiple regression model.

  • PDF

고분자 전해질 연료전지에서 탄소복합 기체확산층의 제조와 특성분석 (Preparation and Characterization for Carbon Composite Gas Diffusion Layer on Polymer Electrolyte Membrane Fuel Cells)

  • 심중표;한춘수;선호정;박경세;이지정;이홍기
    • 한국수소및신에너지학회논문집
    • /
    • 제23권1호
    • /
    • pp.34-42
    • /
    • 2012
  • Gas diffusion layers (GDLs) of carbon composite type in polymer electrolyte fuel cells were prepared by simple and cheap manufacturing process. To obtain the carbon composite GDLs, carbon black with polymer binder was mixed in solvent, rolled to make sheet, and finally heat-treated at $340^{\circ}C$. The performance of fuel cell using composite GDLs was changed by PTFE content. The physical properties of composite GDLs for pore, conductivity and air permeability were analyzed to compare with the variation of fuel cell performance. The conductivity of composite GDLs was very similar to carbon paper as commercial GDL but pore properties and air flux were considerably different. The porosity, PTFE content and conductivity for composite GDLs did not have an influence on the cell performance much. The increase of pore diameter and air flux led to enhance cell performance.

N-type 고효율 태양전지용 Boron Diffused Layer의 형성 방법 및 특성 분석 (Boron Diffused Layer Formation Process and Characteristics for High Efficiency N-type Crystalline Silicon Solar Cell Applications)

  • 심경배;박철민;이준신
    • 한국전기전자재료학회논문지
    • /
    • 제30권3호
    • /
    • pp.139-143
    • /
    • 2017
  • N-type crystalline silicon solar cells have high metal impurity tolerance and higher minority carrier lifetime that increases conversion efficiency. However, junction quality between the boron diffused layer and the n-type substrate is more important for increased efficiency. In this paper, the current status and prospects for boron diffused layers in N-type crystalline silicon solar cell applications are described. Boron diffused layer formation methods (thermal diffusion and co-diffusion using $a-SiO_X:B$), boron rich layer (BRL) and boron silicate glass (BSG) reactions, and analysis of the effects to improve junction characteristics are discussed. In-situ oxidation is performed to remove the boron rich layer. The oxidation process after diffusion shows a lower B-O peak than before the Oxidation process was changed into $SiO_2$ phase by FTIR and BRL. The $a-SiO_X:B$ layer is deposited by PECVD using $SiH_4$, $B_2H_6$, $H_2$, $CO_2$ gases in N-type wafer and annealed by thermal tube furnace for performing the P+ layer. MCLT (minority carrier lifetime) is improved by increasing $SiH_4$ and $B_2H_6$. When $a-SiO_X:B$ is removed, the Si-O peak decreases and the B-H peak declines a little, but MCLT is improved by hydrogen passivated inactive boron atoms. In this paper, we focused on the boron emitter for N-type crystalline solar cells.

고온 고분자 막 전해질 연료전지 캐소드의 가스 확산층 및 바인더 함량에 따른 완화 시간 분포(DRT) 저항 분석 (Resistance Analysis by Distribution of Relaxation Time According to Gas Diffusion Layers and Binder Amounts for Cathode of High-temperature Polymer Electrolyte Membrane Fuel Cell)

  • 김동희;정현승;박찬호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권3호
    • /
    • pp.283-291
    • /
    • 2023
  • The physical properties were analyzed for four gas diffusion layers, and gas diffusion electrodes (GDEs) for the cathode of high-temperature polymer electrolyte membrane fuel cell were fabricated through bar coating with three binder to carbon (B/C) ratios. Among them, The GDE from JNT30-A6P showed a significant change in secondary pore volume at a B/C ratio of 0.31, which had the largest pore volume among all GDEs. In the polarization curve, JNT30-A6P GDE showed the best membrane electrode assembly (MEA) performance with a peak power density of 384 mW/cm2 at a a B/C ratio of 0.31. From the distribution of relaxation time analysis, the peak 1 corresponding to mass transfer resistance of oxygen reduction reaction (ORR) was significantly reduced in the JNT30-A6P GDE. This is the result that when the binder content decreased, the volume of the secondary pore increased, and the mass transfer resistance of ORR decreased, which played an essential role in the MEA performance.

Diffusion-weighted Magnetic Resonance Imaging for Predicting Response to Chemoradiation Therapy for Head and Neck Squamous Cell Carcinoma: A Systematic Review

  • Sae Rom Chung;Young Jun Choi;Chong Hyun Suh;Jeong Hyun Lee;Jung Hwan Baek
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.649-661
    • /
    • 2019
  • Objective: To systematically review the evaluation of the diagnostic accuracy of pre-treatment apparent diffusion coefficient (ADC) and change in ADC during the intra- or post-treatment period, for the prediction of locoregional failure in patients with head and neck squamous cell carcinoma (HNSCC). Materials and Methods: Ovid-MEDLINE and Embase databases were searched up to September 8, 2018, for studies on the use of diffusion-weighted magnetic resonance imaging for the prediction of locoregional treatment response in patients with HNSCC treated with chemoradiation or radiation therapy. Risk of bias was assessed by using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. Results: Twelve studies were included in the systematic review, and diagnostic accuracy assessment was performed using seven studies. High pre-treatment ADC showed inconsistent results with the tendency for locoregional failure, whereas all studies evaluating changes in ADC showed consistent results of a lower rise in ADC in patients with locoregional failure compared to those with locoregional control. The sensitivities and specificities of pre-treatment ADC and change in ADC for predicting locoregional failure were relatively high (range: 50-100% and 79-96%, 75-100% and 69-95%, respectively). Meta-analytic pooling was not performed due to the apparent heterogeneity in these values. Conclusion: High pre-treatment ADC and low rise in early intra-treatment or post-treatment ADC with chemoradiation, could be indicators of locoregional failure in patients with HNSCC. However, as the studies are few, heterogeneous, and at high risk for bias, the sensitivity and specificity of these parameters for predicting the treatment response are yet to be determined.

인산형 연료전지의 다공성전극 제조에 관한 기초적연구 (Fundamental Studies on the Manufactruring of prouse Electrode for Plosphoric Acid Fuel Cell.)

  • 김영우;박정일;이주성
    • 한국표면공학회지
    • /
    • 제22권2호
    • /
    • pp.55-61
    • /
    • 1989
  • A fuel cell which causes electrochemical ratio of conventional with oxygen consists of mainly there parts, such as electrolyte, fuel and oxidant electrode. IN this paper, most efforts were delivered to manufacturing PETE-bonded gas-diffusion electrode, and preparation methods of the porous electrodes has been discussd. A medio temperature, phosphoric acid fuel cell (PAFC) provided with fuel (hydrogen) and oxygen showed oxygen showed excellent performance characteristics with made electrodes. Performance data obtained from hydrgen-oxygen cell were presented to illustrate their properties. It was found that the optimum amounts of platinum in clectrode for hydrgen-oxygen PAFC were about 3mg/cm3 and the PTFE content of gas diffusion layer and catalyst layer were 25% and 15%, respectively.

  • PDF

고분자전해질 연료전지 체결조건에서 기체확산층의 특성변화 및 물거동 확인 (Property changes of GDLs and water behaviors in PEFCs)

  • 박구곤;임남윤;안은진;박진수;윤영기;이원용;임태원;김창수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.313-315
    • /
    • 2006
  • Proper water management is important to achieve high performance and durability of Polymer electrolyte fuel cell (PEFC). Among various stack components, gas diffusion layer (GDL) is considered as a core part to determine the gas and water transportation in a cell. To optimize the water management, the changes of properties as well as basic properties of GDLs were investigated before and after clamping of colls. Thickness, electric conductivity, porosity, hydroppobicity etc. were characterized by the same criteria. The amount of residual water after cell operation also was compared by direct measuring of weight. Based on the amount of residual water the endurance on the freeze condition was evaluated.

  • PDF