• Title/Summary/Keyword: Ceiling Frame

Search Result 34, Processing Time 0.031 seconds

A Study of Asbestos Stabilizer Treatment Considering the Actual Environment of Ceiling Materials (실제 환경을 고려한 천장텍스의 석면안정화제 처리 연구)

  • Shin, Hyungyoo;Choi, Youngkue;Jeon, Boram;Ha, Jooyeon;Sun, Yleshik;Park, Whame
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2016
  • Objectives: This study aimed to confirm the optimal processing conditions of the asbestos stabilizer by considering various actual environments at the time of stabilization treatment of the ceiling materials containing asbestos with asbestos stabilizer. Methods: The anti-scattering performances of the asbestos stabilizer were confirmed by considering the method and quantity of the asbestos stabilizer treated, comparing the loss weight by measuring the weight of ceiling materials prior to and after having treated 30, 50, 100, 200, and 400 of stabilizer using the brush and spray. The effects of backside dust and steel frame structure on the performances of the stabilizer was also confirmed by comparing samples with and without the dust on the rear surface removed by wiping the ceiling material specimens and the blinding treatment simulated by using tape. Results: The asbestos stabilization treatment using the brush method in comparison with the use of a spray has reduced stabilizer loss, resulting in better anti-scattering performance. In addition, the stabilizer loss is increased with increasing treatment quantity; as a result, treating a larger quantity of stabilizer does not improve the performance. For the conditions related to ceiling materials, the anti-scattering performance is enhanced by removing the backside dust and spreading the stabilizer evenly on the masking portion by steel frame structures. Conclusions: Based on these results, it is determined that the appropriate choice of the tool used for the treatment of the asbestos stabilizer and the appropriate quantity of asbestos stabilizer were needed at the time of actual stabilization processing of the ceiling materials containing asbestos. Moreover, this study confirmed that preliminary processing and verification of the structure at which the ceiling materials are installed can enhance the effectiveness of prevention of the scattering of asbestos into the air.

Triaxial Shake Table Test about Seismic Performance of Ceiling System with Gypsum Panels (석고 패널이 부착된 천장 시스템의 내진성능 평가를 위한 3축 진동실험)

  • Park, Hae-Yong;Jeon, Bub-Gyu;Kim, Jae-Bong;Gim, Min-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, a full scale 3-axes shake table test for M-bar and T-bar type ceilings commonly used in the country was conducted. Through damage inspection during the test, seismic performance of ceilings according to variables, such as clearance between wall mold and ceiling as well as existence of facilities, was evaluated. A test frame consisted of square hollow section members was used for the shake table test. The experimental method was performed as a fragility test using required response spectrum described in ICC-ES AC156. In the case of architectural nonstructural component that contain ceilings, it mainly is evaluated the performance by post-test visual inspection. For the evaluation of seismic performance of ceilings, this study classified and defined damaged items for targeted ceiling system referring to illustrative damage according to nonstructural performance levels accordance with ASCE 41 and previous studies. And proposed illustrative damage items classification was utilized to compare the degree of the damage according to experimental variables. The experiment results confirmed that differences in boundary conditions due to the clearance at wall mold and the installation of facilities had a significant effect on the seismic performance of the ceiling.

A Study on the Adaptation of Traditional Interior Elements in Restaurants and Cafe (전통주택 실내구성요소의 현대적 계승사례에 관한연구 -월간잡지에 나타난 식음료 공간을 중심으로-)

  • 오혜경;성미현
    • Korean Institute of Interior Design Journal
    • /
    • no.17
    • /
    • pp.45-51
    • /
    • 1998
  • A purpose of this study was to investigate actual condition of the modern adaptation of interior elements(wall, floor, ceiling. door & window) in traditional house. The examined objects were 185 pictures of restaurants and cafe interior spaces from the 5 different monthly magazines between jan. 1993. to Dec 1997. The results of this study were as follows : 1. Mostly they were either partial adaptation from the original or partially transformed adaptation rather than entire adaptation of the original. 2. Of the traditional interior elements adapted in restaurants and cafe space only specific elements were being adapted. For example partial adaptation from the original were oiled paper flooring(Jangpan) plaster wall ceiling finish that left the rafters and beams exposed(Yondung-chonjang) and window or door frame which is vertical lattices accented with horizontal lattices grouped into three sections(Ttisal-mum) And partially transformed adaptation were oiled paper flooring rice papered (Hangji) wall Yondung-chonjang window or door frame of Wan character(Wanja-mun). 3, In regard to space the mostly adapted spaces were halls rather than rooms.

  • PDF

A study on the Adaptation of Traditional Interior Elements in Modern House (전통주택 실내구성요소의 현대적 계승사례에 관한연구 -월간잡지에 나타난 주거공간을 중심으로-)

  • 오혜경
    • Journal of Families and Better Life
    • /
    • v.16 no.4
    • /
    • pp.167-182
    • /
    • 1998
  • The purpose of this study was to investigate actual condition of the modern adaptation of interior elements (wall floor ceiling door & window) in traditional house. The examined objects were 316 pictures of residential interior spaces from the 5 different monthly magazines between Jan. 1993 to Dec. 1997 The results of this study were as follows; 1. Mostly they were either parital adaptation from the original or partially transformed adaptation rather than entire adaptation of the original 2. Of the traditional interior elements adapted in residential space only specific elements were being adapted. For example. partial adaptation from the original were oiled paper flooring(Jangpan) rice papered wall (Hanji) a ceiling finish that left the rafters and beams exposed (Yondunt-chonjang) and window or door frame which is vertical lattices accented with horizontal lattices grouped into three sections(Ttisal-mun)And partially transformed adaptation were wood flooring(Chang-maru) rice apered wall(Hanji) Yondung-chonjang wind or door frame of Wan character(Wanja-mum) 3. In regard to space the mostly adapted spaces were bedrooms rather than living or dining rooms.

  • PDF

Priority on Work Improvement for Automation of Ceiling Finishing Work (천장마감공사 자동화기술 적용을 위한 작업개선 우선순위 도출)

  • Lee, June-Hyuck;Lee, Dongyoun;Kang, Goune;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.187-188
    • /
    • 2015
  • The construction finishing work is emphasized according to high dependence on labor and long term that occupy approximately 40% in construction period, so that it is required for the alternatives such as automation technology. However, it is insufficient to develop the automation technology of construction finishing work compared to other works, for instance, frame work. Also it is not enough about this preliminary research which survey the improvement needs to select the development object. Therefore, this study aimed at derivation of detail works required improvement in ceiling finishing work by the questionnaire survey. These results may provide the basic information to develop the automation technology of construction finishing work.

  • PDF

Seismic Performance and Design Process of a Ceiling Bracket-Typed Modular Connection (천장 브래킷형 모듈러 시스템의 접합부 내진 성능과 설계 프로세스)

  • Lee, Seungjae;Kang, Changhoon;Park, Jaeseong;Kwak, Euishin;Shon, Sudeok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.3
    • /
    • pp.27-34
    • /
    • 2020
  • This paper examines the seismic performance and structural design of the ceiling bracket-type modular connection. The bracket-type system reduces the cross-sectional area loss of members and combines units using fitting steel plate, and it has been developed to be fit for medium-story and higher-story buildings. In particular, this study conducted the cyclic loading test for the performance of the C-type and L-type brackets, and compared the results. The test results were also compared with the commercial FEA program. In addition, the structural design process for the bracket-type modular connection was presented. The two connections, proposed as a result of the test results, were all found to secure the seismic performance level of the special moment steel frame. In the case of initial stiffness, the L-type bracket connection was found to be great, but in the case of the maximum moment or fully plastic moment, it was different depending on the loading direction.

Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket (천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능)

  • Lee, Seung-Jae;Kwak, Eui-Shin;Park, Jae-Seong;Kang, Chang-Hoon;Shon, Su-Deok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

Seismic Performance Evaluation of the Ceiling Bracket-type Modular System with Various Bracket Lengths and Bolt Types (천장 브래킷형 모듈러 시스템의 브래킷 길이와 볼트에 따른 내진성능평가)

  • Kwak, Eui-Shin;Kang, Chang-Hoon;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.25-33
    • /
    • 2018
  • In regard to modular systems, new methods, as well as middle and high-story unit design ideas, are currently being studied. These studies need to focus on the enhanced stiffness and seismic performance of these connections, and see that the development of fully restrained moment connections can improve the seismic performance. For this reason, this study evaluates the performance of the connections of the ceiling bracket-typed modular system through repeated loading tests and analyses. In order to compare them with these modular units, new unit specimens with the bracket connection being different from that of the traditional modular unit specimens were designed, and the results of repeated loading tests were analyzed. In the traditional units, the structural performances of both welding connection and bolt connection were evaluated. In regard to the testing results, the initial stiffness of the hysteresis curve was compared with the theoretical initial stiffness, and the features of all specimens were also analyzed with regard to the maximum moment. In addition, the test results were examined with regard to the connection flexural strength of the steel special moment frame specified under the construction criteria KBC2016. The connections, which were proposed in the test results, were found to be fully restrained moment connections for designing strong column-weak beams and meeting the requirements of seismic performance of special moment frames.

A Study on the Characteristics of Fire Resistance of Window Material in Compartment Fire (건물화재시 창문재료에 따른 내화특성 연구)

  • Hur, Man-Sung;Jang, Moon-Seok;Cho, Soo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-67
    • /
    • 2003
  • The full-scale compartment fire tests were carried out to evaluate the characteristics of fire resistance of window material under actual fire conditions. The room size used for full-scale room fire tests was 4 by 3.8 m with 2.4 m high ceiling. The windows with PVC, Aluminum and AL+Wood frame materials were established, sofa and mattress were used as fire sources. The window contained pair glasses with the air between 6 mm glasses. Temperatures at total 32 points in the room were measured to find the temperature distribution in the room fire. It is examined that thermal effects on window frame materials such as charring, distortion, melting, structural collapse, and other effects.

Remodeling Project of the 'Yeonsinae' Catholic Church (연신내 성당 리모델링 구축 프로젝트)

  • Bae, Kang-Hee;Lee, Hyok-Jun
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.53-54
    • /
    • 2006
  • Recently with increasing interest in the operation of life cycle, building remodeling business is spreading like a fashion. Keeping pace with the trend, the present project carried out the remodeling of an existing neighborhood facility into a religious facility based on the concepts of remodeling, reform and renovation. Basic requirements were overcoming spatial limitations, solving structural problems, meeting various functional needs, and securing a spatial size, and the project designed the interior of the building according to these requirements suggested by the owner. To overcome the low floor height of the existing space, the main sanctuary on the 1st floor had the ceiling in the form of a slant and installed indirect lighting into the resulting gaps, maximizing the depth and width of the space visually. The subsidiary sanctuary on the first basement was finished with red bricks, forming an arch using the bricks, to create religious atmosphere. However, considering the low floor height as in the 1st floor and the ceiling even lowered by the arch structure, the arch was formed threefold and the radius of the curvature of the arch was enlarged to secure a spacious feeling. The outer appearance was finished with granite on existing structure to save the cost of construction. In addition to the use of the finishing material, the structure of the arch and the frame of the opening part and the finishing of the walls were expressed with uneven surface in order to avoid the plainness of the appearance.

  • PDF