• Title/Summary/Keyword: Cavity thickness

Search Result 319, Processing Time 0.032 seconds

The Effect of the Attached Glazing and Windbreak on the Thermal Performance and Air Tightness of Sliding window (덧유리 및 방풍재 적용을 통한 슬라이딩 창의 단열 및 기밀성능 개선효과 분석)

  • Bae, Min-Jung;Kang, Jae-Sik;Choi, Gyeong-Seok;Choi, Hyung-Joung
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.59-65
    • /
    • 2017
  • Purpose: Thermal performance and air tightness of window are improved for the building energy efficiency. As the deteriorated houses are increased, the improve measures with low cost and easy installation are developed in the energy performance of window. Attached glazing and windbreak can be easily applied to the window with low cost. In this paper, the effect of the attached glazing and windbreak on the thermal performance and air tightness of window is analyzed as the measure to improve performance of window. Method: Thermal transmittance of glazing is evaluated through WINDOW simulation according to thickness of attached glazing and air cavity. Based on the simulation results, thermal transmittance, air tightness and condensation resistance performance of four cases are tested according to Korea standards. One type of PVC sliding double window is chosen as the specimen. For the analysis on low performance of window, the outside of window is excluded in the PVC sliding double window. Result: This study shows that thermal performance of glazing can be increased by the application of attached glazing. Furthermore, lower thermal performance of glazing can obtain the higher effect of attached glazing. The application of attached glazing and windbreak can effect on increasing thermal performance and air tightness of window.

Adipofascial Anterolateral Thigh Flap Safety: Applications and Complications

  • Agostini, Tommaso;Lo Russo, Giulia;Zhang, Yi Xin;Spinelli, Giuseppe;Lazzeri, Davide
    • Archives of Plastic Surgery
    • /
    • v.40 no.2
    • /
    • pp.91-96
    • /
    • 2013
  • Background A thinned anterolateral thigh (ALT) flap is often harvested to achieve optimal skin resurfacing. Several techniques have been described to thin an ALT flap including an adipocutaneous flap, an adipofascial flap and delayed debulking. Methods By systematically reviewing all of the available literature in English and French, the present manuscript attempts to identify the common surgical indications, complications and donor site morbidity of the adipofascial variant of the ALT flap. The studies were identified by performing a systematic search on Medline, Ovid, EMBASE, the Cochrane Database of Systematic Reviews, Current Contents, PubMed, Google, and Google Scholar. Results The study selection process was adapted from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, and 15 articles were identified using the study inclusion criteria. These articles were then reviewed for author name(s), year of publication, flap dimensions and thickness following defatting, perforator type, type of transfer, complications, thinning technique, number of cases with a particular area of application and donor site morbidity. Conclusions The adipofascial variant of the ALT flap provides tissue to fill large defects and improve pliability. Its strong and safe blood supply permits adequate immediate or delayed debulking without vascular complications. The presence of the deep fascia makes it possible to prevent sagging by suspending and fixing the flap for functional reconstructive purposes (e.g., the intraoral cavity). Donor site morbidity is minimal, and thigh deformities can be reduced through immediate direct closure or liposuction and direct closure. A safe blood supply was confirmed by the rate of secondary flap debulking.

A Study on Controlling of Cracks Occurred at Crown of Tunnel Concrete Lining using Model Test (모형 실험에 의한 터널 콘크리트 라이닝의 천단부 균열 제어에 관한 연구)

  • Jeon, Joong-Kyu;Jeon, Chan-Ki;Kim, Nag-Young;Kim, Su-Man;Lee, Jong-Eun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.3
    • /
    • pp.227-235
    • /
    • 2006
  • The problematic issue of cracking, water shedding in tunnel is recently coming out in the view of the structural stability. Hence, the assessment is required for the existing tunnels to achieve the structural soundness of tunnels, and their safety and maintenance. In this study, fracture behaviour and displacement of a tunnel concrete lining using steel fiber reinforcement concrete was investigated. The specimens were fabricated in single lining for a model of real road tunnel. As parameters, load condition, thickness of lining, whether or not rear cavity in crown, and a ratio of steel fiber in concrete were taken. From these factors, the load for crack and fracture, displacement, and the pattern of crack were looked into for the structural stability of a tunnel concrete lining.

Evaporation Characteristics of Aluminum by Using Surface-treated Graphite Boat (표면처리된 흑연 보트를 이용한 알루미늄의 증발 특성)

  • Jeong, J.I.;Yang, J.H.
    • Journal of Surface Science and Engineering
    • /
    • v.42 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Resistive heating sources are widely used to prepare thin films by vapor deposition because they are cheap, and easy to install and handle in vacuum system. Graphite is one of materials used to make the resistive heating source, but until now only limited applications have been possible as it reacts easily with evaporating materials at high temperature. In this study, evaporation characteristics of aluminum have been investigated by using graphite boat thermally treated with BN powder. The employed graphite boat has been prepared by spray-coating BN power onto the cavity surface of the boat and thermal treatment with aluminum in vacuum at the temperature of more than $1400^{\circ}C$. The voltage-current characteristics as well as resistivity changes of the graphite boat have been investigated during aluminum evaporation according to the applied voltage and time. The evaporation aspect has been picturized during flash evaporation for 40 seconds based on the characterization results. The evaporation rate of the graphite boat has been compared with that of BN boat. The graphite boat showed some different characteristics compared with BN boat, in that the evaporation occurred at the last stage of flash evaporation. The film appearance according to the applied voltage has been compared, and also the reflectance of the resulting film has been investigated according to the film thickness. It has been found that the graphite boat thermally treated with BN powder can be used for aluminum evaporation without problem.

Formation of Silicon Diaphragm Using Silicon-wafer Direct Bonding / Electrochemical Etch-stopping and Its Application to Silicon Pressure Sensor Fabrication (실리콘 직접 접합 / 전기화학적 식각정지를 이용한 실리콘 다이아프램의 형성과 실리콘 압력센서 제조에의 응용)

  • Ju, B.K.;Ha, B.J.;Kim, K.S.;Song, M.H.;Kim, S.H.;Kim, C.J.;Tchah, K.H.;Oh, M.H.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.45-53
    • /
    • 1994
  • A new type of Si diaphragm was fabricated using Si-wafer direct bonding and two-step electrochemical etch-stopping methods. Using the new diaphragm structure in mechanical sensors, more precise control of cavity depth and diaphragm thickness was achievable. Also, the propagation of the stress, which was generated near the bonding interface, to the surface can be avoided. Finally, a piezoresistive-type Si pressure sensor was fabricated utilizing the diaphragm and a digital pressure gauge, which can display units of pressure, was realized.

  • PDF

A Case of Chest Pain in Taeumin Caused by Aortic Regurgitation Treated with Gamijoripewontang (대동맥판(大動脈瓣) 폐쇄불전증(閉鎖不全症)으로 흉통(胸痛)을 호소하는 태음인(太陰人)환자의 가미조리폐원탕(加味調理肺元湯) 치험례)

  • Kim, Dong-Woo;Kim, Soo-Yong;Han, Chang-Ho;Rhee, Sung-Hwan;Lee, Dong-Min;Ha, Sang-Kyu
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.464-472
    • /
    • 2004
  • Aortic regurgitation occurs when there is a leakage of the valve backward into the left ventricle during diastole. Chronic aortic regurgitation may be present for decades before any symptoms occur. The left ventricle is able to compensate for the large volume of blood that flows backward by enlarging the cavity and increasing the thickness of the muscle. This mechanism allows the heart to pump out both the amount of blood required by the body and the blood that has gone backward into the left ventricle. One patient who had chest pain from exercise was treated. He was diagnosed with aortic regurgitation LVH by echocardiography. Signs showed him to be of Taeumin-type within Sasang Constitutional Medicine. He was prescribed Gamijoripewontang for 75 days, and improvement of clinical symptoms were observed. Results support prescription of Gamijoripewontang as an effective treatment for Taeumin-type patients suffering chest pain caused by aortic regurgitation.

  • PDF

The Effect of Microcurrent Electrical Stimulation on the Articular Cartilage Recovery in Osteoarthritis (비침습식 미세전류자극이 실험적으로 유발된 흰쥐의 골관절염 회복에 미치는 영향)

  • Bang, Hyun-Soo;Kang, Jong-Ho;Cheon, Song-Hee;Kim, Min-Hee;Park, Soo-Jin;Kim, Jin-Sang;Park, Rae-Joon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.151-159
    • /
    • 2007
  • Purpose : The purpose of the study was to investigate the effect of cold application on knee joint in rats induced by osteoarthritis. Methods : Osteoarthritis was induced in female Sprague-Dowley rats by injecting into articular cavity of knee joint with 4% Kaolin, 2% carrageenan. Rats were divided randomly into the control and MES applicated group. The Experimental group was applicated MES in rat knee joint for 30 minutes. Results : Recovery of articular cartilage surface and thickness of articular cartilage increased after MES application. And chondrocytes were distributed widely throughout the cartilage matrix. The physical effects of Microcurrent Electrical Stimulation. Decrease in blood flow. Delay of neurotransmitter velocity Decrease in metabolism activity and inhibit the progress of the infection. Decrease in pain and muscle rigidity, inhibition of circulation Conclusion : This study shows that MES application affects articular cartilage recovery in osteoarthritis.

  • PDF

A study on the Powder Injection Molding of Translucent Alumina via Flowability Simulation of Powder/Binder Mixture (분말사출성형 시 분말 혼합체의 유동성 시뮬레이션을 통한 투광성 알루미나 소결체의 특성 연구)

  • Kim, Hyung Soo;Byun, Jong Min;Kim, Se Hoon;Kim, Young Do
    • Journal of Powder Materials
    • /
    • v.21 no.3
    • /
    • pp.215-221
    • /
    • 2014
  • Translucent alumina is a potential candidate for high temperature application as a replacement of the glass or polymer. Recently, due to the increasing demand of high power light emitting diode (LED), there is a growing interest in the translucent alumina. Since the translucent property is very sensitive to the internal defect, such as voids inside or abnormal grain growth of sintered alumina, it is important to fabricate the defect-free product through the fabrication process. Powder injection molding (PIM) has been commonly applied for the fabrication of complex shaped products. Among the many parameters of PIM, the flowability of powder/binder mixture becomes more significant especially for the shape of the cavity with thin thickness. Two different positions of the gate were applied during PIM using the disc type of die. The binder was removed by solvent extraction method and the brown compact was sintered at $1750^{\circ}C$ for 3 hours in a vacuum. The flowability was also simulated using moldflow (MPI 6.0) with two different types of gate. The effect of the flowability of powder/binder mixture on the microstructure of the sintered specimen was studied with the analysis of the simulation result.

RADIOPACITY OF DENTAL GLASS POLYALKENOATE CEMENTS (치과용 Glass Polyalkenoate cement의 방사선 불투과성에 관한 비교 연구)

  • Rim, Young-Il;Um, Chung-Moon;Lee, Chung-Sik;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.464-469
    • /
    • 1997
  • The radiopacity of glass ionomer cements is quite variable. The use of a poorly radiopaque material as a base under other restorative materials can mislead the dentist to a diagnosis of recurrent decay. This study investigates the radiopacity of these materials and proposes a minimal radiopacity under which a material should not be used as a base or liner. It is important to determine the radiopacity of glass ionomer dental materials so that the clinician can appreciate the type of restorative materials used when radiographically evaluation the possibility of recurrent dental caries. In this study, radiopacity of Vitrement and Chemfil was compared with that of Cavalite, Miracle mix and polycarboxylate cement. Tooth model of artificial cavity preparation for diagnosis of recurrent caries was omitted. Radiopacity of each material was measured using relatives between thickness and radiopacity of Aluminium step wedge. The results were as follows : 1. Radiopacity of Vitrement was some higher than enamel. 2. Chemfil, restorative glass ionomer, was less radiopaque than enamel. 3. In order of higher radiopacity than enamel, Miracle mix was highest and was followed by polycarboxylate cement, Cavalite and Vitremer. 4. Vitremer, the Glass Ionomer Cement, is useful to detection of recurrent caries, because it is slightly higher radiopaque than enamel. So, it is suitable for restorative material and luting cement.

  • PDF

Angiomyoma on Face : A Case Report (안면부에 발생한 혈관근종의 치험례 : 증례보고)

  • Choi, Junho;Chang, Hak
    • Korean Journal of Head & Neck Oncology
    • /
    • v.29 no.2
    • /
    • pp.48-50
    • /
    • 2013
  • Angiomyoma is a rare, benign smooth muscle cell tumor. These tumors may be found anywhere in the body. They frequently occur in the lower extremities except venous type. Angiomyoma in the head and neck area is very rare, and only a few cases have been reported. A 63 year-old male patient visited to outpatient clinic due to size-growing nodule-like lesion in the Lt. alar area. Excisional biopsy was done for diagnosis. The lesion was totally excised with 2 mm safety margin. Frozen biopsy of the lesion was requested, and all resection margins were proved negative. To cover the raw surface, full thickness skin grafting was performed. The graft was harvested from Rt. posterior auricular area. Tie over dressing was applyed on Lt. alar area. The graft was well taken and healed without any complication in both short term and long term follow up periods of 2 weeks, 1 month, 2 months, and 6 months. Donor site completed healed without any complications. The leiomyoma is benign tumor originated from smooth muscle, and it can be classified into solid leiomyoma, angiomyoma, and epithelioid leiomyoma. Especially, the angiomyoma consists of smooth muscle cell and blood vessel, and it is originated from the tunica media of blood vessel. Angiomyoma alone frequently occurs in the lower extremities as solitary painless subcutaneous tumor. Venous type of angiomyoma in the oral cavity was reported in other references, but on the facial surface it may be the first case reported as paper. So this report can be very meaningful.