• Title/Summary/Keyword: Cavity Wall

Search Result 547, Processing Time 0.037 seconds

Variation of the Characteristics of Shock-Interaction Flows for Different Slot-Directions (슬롯방향 변화에 따른 충격파 간섭유동 특성변화에 관한 연구)

  • Chang Sung-Ha;Lee Yong-Hee;Lee Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.306-309
    • /
    • 2006
  • Passive control of the shock wave/turbulent boundary-layer interaction control utilizing slotted plates over a cavity has been carried out. Effect of various slot configurations on the characteristics of the interactions are tested. Pitot/wall surface pressure distributions and flow visualizations including Schlierens and interference fringe patterns over a thin oil-film have been obtained at the downstream of the shock interactions. It was found that the interaction control by a certain slot-configuration could lead a reduction of the total pressure loss through the shock wave, however, the boundary layer thickness became thicker as compared with the case of no control.

  • PDF

Eyeball deviation by orbital mucocele after midface sinus injury

  • Oh, Se Young;Choi, Ji Seon;Lim, Jin Soo;Kim, Min Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.1
    • /
    • pp.53-57
    • /
    • 2020
  • A mucocele is an epithelium-lined, mucus-filled cavity in the paranasal sinuses. Mucocele may develop due to scarring and obstruction of the sinus ostium caused by midface sinus trauma, such as orbital bone fracture or endoscopic sinus surgery. The authors report two cases of orbital mucocele as complications following midface sinus injury (endoscopic sinus surgery in one case, and orbital fracture repair in the other). In both cases, imaging studies showed a large orbital mucocele accompanied by bony erosion and orbital wall remodeling, compressing the ocular muscle. Using an open approach, the lesion was excised and marsupialized. The symptoms resolved, and the postoperative eyeball position was normal. Orbital mucocele may cause serious complications such as ocular symptoms, orbital cellulitis, osteomyelitis, and the formation of an abscess with the potential to invade the brain. Therefore, surgeons should consider the possibility of mucocele as a late complication of surgery and initiate an immediate work-up and surgical treatment if needed.

IMPROVEMENT OF A SEMI-IMPLICIT TWO-PHASE FLOW SOLVER ON UNSTRUCTURED MESHES (비정렬 격자계에서의 물-기체 2상 유동해석코드 수치 기법 개선)

  • Lee, H.D.;Jeong, J.J.;Cho, H.K.;Kwon, O.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.380-388
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been developed for the analysis of transient two-phase flows in nuclear reactor components. A two-fluid three-field model was used for steam-water two-phase flows. To obtain numerical solutions, the finite volume method was applied over unstructured cell-centered meshes. In steam-water two-phase flows, a phase change, i.e., evaporation of condensation, results in a great change in the flow field because of substantial density difference between liquid and vapor phases. Thus, two-phase flows are very sensitive to the local pressure that determines the phase change. This in turn puts emphasis on the accurate evaluation of local pressure gradient. This paper presents a new numerical scheme to evaluate the pressure gradient at cell centers on unstructured meshes. The results of the new scheme for a simple test function a gravity-driven cavity, and a wall boiling two-phase flow are compared with those of the previous schemes in the cupid code.

  • PDF

A Study of the Passive Shock/Boundary Layer Interaction Control in Transonic Moist Air Flow (천음속 습공기 유동에서 발생하는 충격파와 경계층 간섭의 피동제어에 관한 연구)

  • Baek Seung-Cheol;Kwon Soon-Bum;Kim Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.161-164
    • /
    • 2002
  • In the present study, a passive control method, using the porous wall and cavity system, is applied to the shock wave/boundary layer interactions in transonic moist air flow. The two-dimensional, unsteady, compressible Navier-Stokes equations, which are fully coupled with a droplet growth equation, are solved by the third-order MUSCL type TVD finite difference scheme. Baldwind-Lomax turbulence model is employed to close the governing equations. In order to investigate the effectiveness of the present control method, the total pressure losses of the flow and the time-dependent behaviour of shock motions are analyzed in detail. The computed results show that the present passive control method considerably reduces the total pressure losses due to the shock/boundary layer interaction in transonic moist air flow and suppresses the unsteady shock wave motions over the airfoil, as well. It is also found that the location of the porous ventilation significantly influences the control effectiveness.

  • PDF

The Effect of Heat Transfer from the Bubble Growing on the $B\dot{e}nard$ Convection Flow in a Square Cavity ($B\dot{e}nard$ 대류가 형성된 사각공동내의 상단 평판에서 기포의 성장이 열전달에 미치는 영향)

  • Eom, Yong-Kyoon;Kwon, Seung-Hye;Kwon, Gi-Han
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.211-216
    • /
    • 2001
  • Flow motion and variation of thermal field around a bubble which attached at the upper cooled solid wall in a $B\dot{e}nard$ convection flow is studied experimentally using thermo-sensitive liquid-crystal tracers and image processing for flow visualization and analysis. The air is injected gradually by $0.1m\ell$ to make the bubble. As the growing of the bubble in a $B\dot{e}nard$ convection flow, the variation of temperature field and surface tension along the bubble, which in turn cause to change the thermal field patterns and the flow direction and patterns. 6 cells flow pattern is transformed into diverse flow pattern. At the large size of a bubble, it's only conduction mechanism under the region of the bubble because of low Ra number 1137, but the convection flow both sides of the bubble leads to another convection flow in the bubble influence area which has been remained stable stagnation.

  • PDF

Passive Control of Condensation Shock Wave in a Transonic Nozzle (천음속 노즐에서 발생하는 응축충격파의 피동제어)

  • Kim, Hui-Dong;Baek, Seung-Cheol;Gwon, Sun-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.666-674
    • /
    • 2002
  • A rapid expansion of the moist air or stream through transonic nozzle often leads to not-equilibrium condensation shock, causing a considerable amount of energy loss to the entire flow field. Depending on amount of heat released, condensation shock wave occurs in the nozzle and interacts with the boundary layer flow. In the current study, a passive control technique using a porous wall with a plenum cavity underneath is applied for purpose of alleviation the condensation shock wave in a transonic nozzle. A droplet growth equation is incorporated into two-dimensional wavier-Stokes equation systems. Computations are carried out using a third-order MUSCL type TVD finite-difference scheme with a second-order fractional time step. An experiment using an indraft transonic wind tunnel is made to validate the present computational results. The results obtained show that the magnitude of condensation shock wave is reduced by the current passive control method.

Enhancement of Sound Clarity of Classrooms Using Sound Diffusers and Panel Absorbers

  • Shin, Sang-Bong;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2E
    • /
    • pp.60-65
    • /
    • 2009
  • The present study aims to investigate the effects of sound diffusers and absorbers on the sound clarity in classrooms. In order to do this, computer simulations were carried out to find the effective area of treatment which could enhance the sound clarity in the room. Acoustic measurements were undertaken in a lecture room with several conditions changing the surface of walls and ceilings with diffusers and absorbers. Diffusion and absorption treatments were applied to the side walls, rear wall and the ceiling of the classroom. SPL, RT, D50, RASTI were measured at 9 measurement points with one sound source and MLS was used as the sound source signal. The results show that higher sound clarity was obtained when diffusers were applied to rear walls and ceiling rather than side walls. Also, it was confirmed that absorption increased sound clarity more effectively with smaller amount in comparison with diffusers. It was also concluded that the effects of sound diffusers and absorbers on the sound clarity could be obtained distinctly at the rear area of the classroom.

Springback Characteristics of Bent Tubes for Hydroforming Applications (하이드로포밍 응용을 위한 벤딩튜브의 스프링백 특성)

  • Lee, H.K.;Park, S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.06a
    • /
    • pp.45-48
    • /
    • 2006
  • Recently, the use of tubular hydroforming technology has seen increased usage and increased consideration for wide range of tubular automotive applications. In manufacturing hydroformed parts, bending and pre-forming operations are often required prior to the hydroforming process. Higher bending quality of bent tubes is crucial for the successful hydroforming operation because most of plastic strains and wall thinning at the extrados of bend area occur in the bending operation. Springback is also observed due to elastic recovery of tube material after bending. Proper correction of springback is required not only to well place the bent tube into a hydroforming die cavity but also to avoid pinching when the upper die is brought down to closing position. Therefore, prediction of springback at early development stage is one of the key factors to produce high quality hydroformed parts. In this study, a variety of bending experiments has been carried out to investigate springback amount under change in bending angle and material boosting. Throughout the experimental approach, springback characteristics of bent tubes are quantified according to the change in various bending parameters, and a mathematical model to predict correction amount of springback to a given bend angle is found.

  • PDF

Surgical Treatment of Empyema using Intrathoracic Transposition of Extrathoracic Skeletal Muscles (흉곽내로 전위시킨 골격근을 이용한 농흉의 외과적 치료)

  • Kim, Gi-Bong;Park, Jong-Ho
    • Journal of Chest Surgery
    • /
    • v.25 no.6
    • /
    • pp.630-636
    • /
    • 1992
  • From August 1990 through December 1991, 14 patients[all males] underwent int-rathoracic muscle transposition of extrathoracic skeletal muscles to treat empyemas, 6 patients had tuberculous empyemas, 4 had chronic empyemas of unknown etiology, 3 had pos-tpneumonectomy empyemas, and 1 had postlobectomy empyema. 9 patients had associated bronchopleural fistulas, Their ages ranged from 22 to 67 years, with mean age of 45.1$\pm$17. 6[$\pm$S.D] years. The serratus anterior was transposed in 13 patients, the latissimus dorsi in 12. In 11 patients, both the serratus anterior and the latissimus dorsi were transposed. The omental flap also transposed in 3 patients. To reduce the dead space in the thoracic cavity, thr-oacoplasty was also carried out in 10 patients. The number of the partially resected ribs was 3.0$\pm$0.8[$\pm$S.D.]. All operations were single stage procedures, and all wounds were closed primarily, with no permanent tubes or chest wall openings. There was no hospital mortality, and so no subsequent operation has been required. Follow-up of the patients ranged from 5 to 16 months with a mean of 9.2$\pm$3.1[$\pm$S.D] months, All the patints had no further signs or symptoms of the original infection after discharge. We conclude that intrathoracic transposition of extrathoracic skeletal muscle is an excellent method of treatment for persistent, life-threatening intrathoracic infections.

  • PDF

Traumatic Extrapleural Hematoma Mimicking a Hemothorax (혈흉으로 오인된 흉막외혈종)

  • Park, Young-Woo;Lee, Jae-Wook;Lee, Dong-Gi
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.328-331
    • /
    • 2010
  • Extrapleural hematoma results from blood accumulating between the parietal pleura and the endothoracic fascia, whereas hemothorax shows pooling in the pleural space. Extrapleural hematoma results from an intact parietal pleura that blocks blood from escaping the pleural cavity. Extrapleural fat, a fat layer outside the pleura in the chest wall between the parietal pleura and the endothoracic fascia, is pathognomonic on computed tomography. We diagnosed traumatic extrapleural hematoma and treated it with video-assisted thoracic surgery. We report here on this case along with a review of the literature.