• 제목/요약/키워드: Cavity Pressure Monitoring

검색결과 20건 처리시간 0.043초

탄소섬유강화복합소재의 고압수지이송성형공정에서 금형 내 캐비티의 압력 및 온도신호에 따른 성형특성 (Forming Characteristics with Cavity Pressure and Temperature Signal Inside Mold in High-Pressure Resin Transfer Molding Process of Carbon Fiber Reinforced Composite Material)

  • 한범정;정용채;김성렬;김노원;강명창
    • 한국기계가공학회지
    • /
    • 제16권6호
    • /
    • pp.81-86
    • /
    • 2017
  • The high-pressure resin transfer molding (HP-RTM) process has a very effective for the mass production of carbon fiber reinforced plastic (CFRP) for light weight in the automotive industry. In developing robust equipment, new process and fast cure matrix systems reduces significantly the cycle time less than 5 minutes in recent years. This paper describes the cavity pressure, temperature and molding characteristics of the HP-RTM process. The HP-RTM mold was equipped with two cavity pressure sensors and three temperature sensors. The cavity pressure characteristics of the HP-RTM injection, pressurization, and curing processes were studied. This experiment was conducted with selected process parameters such as mold cap size, maximum press force, and injection volume. Consequently, this monitoring method provides correlations between the selected process parameters and final forming characteristics in this work.

사출성형기 실린더와 금형 캐비티의 실시간 모니터링을 이용한 사출성형공정 비교 분석 (Comparative Analysis of Injection Molding Process by On-line Monitoring in Cylinder of Injection Molding Machine and in Cavity of Mold)

  • 박형필;차백순;태준성;최재혁;이병옥
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1513-1519
    • /
    • 2010
  • 최근 고품질 제품 생산을 위한 방법으로 센서를 이용한 사출공정모니터링 시스템이 적용되고 있다. 그러나 마이크로 금형, 광학용 금형 및 구조가 복잡한 금형에는 센서 설치가 어렵기 때문에, 공정 모니터링 시스템이 적용되기 어려운 단점이 있다. 본 연구에서는 금형과 사출성형기 노즐의 압력 을 측정하여 공정 모니터링 데이터의 정량적 지수를 정의하고, 성형품 중량에 대한 상관분석을 수행하여 노즐에 설치된 압력센서의 공정모니터링 적용성을 알아보았다. 또한 공정모니터링 데이터를 분석하여 다단사출속도, 보압 및 제한 사출 압력의 영향에 따른 사출성형기의 공정 제어 특성도 알아보았다.

현장진단용 단백질 칩 사출금형기술 (Injection Mold Technology of Protein Chip for Point-of-Care)

  • 이성희;고영배;이종원;정해철;박재현;이옥성
    • Design & Manufacturing
    • /
    • 제6권2호
    • /
    • pp.74-78
    • /
    • 2012
  • A multi-cavity injection mold system of protein chip for point-of-care with cavity temperature and pressure sensors was proposed in this work. In advance of manufacturing for the multi-cavity injection mold system, a single cavity injection mold system to mold protein chip was considered. Injection molding analysis for the presented system was performed to optimize the process of the molding and suggest guides to design. On the basis of the results for the single cavity system, a multi-cavity injection mold system for protein chip was analyzed, designed and manufactured with cavity temperature and pressure sensors. Results of balanced filling for protein chip models were obtained from the presented mold system.

  • PDF

환경 모니터링을 위한 압력 센서 연구 (A Study of Pressure Sensor for Environmental Monitoring)

  • 황현석;최원석
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.225-229
    • /
    • 2011
  • 본 연구에서는 환경 모니터링을 위한 정전용량형 압력센서를 저온동시소성세라믹 (LTCC) 기술을 이용하여 제작하였다. LTCC 기술은 실리콘 기반의 기술에 비하여 낮은 생산 단가, 높은 수율, 3차원 구조물의 용이한 제작성 등으로 인하여 센서 응용분야에서 중요한 역할을 담당하고 있으며, 특히 열악한 외부환경에 적합한 물질이다. 400 ${\mu}m$ 두께 삼차원 구조의 LTCC 다이어프램은 NEG사의 MLS 22C 상용 파우더를 이용하여 100 ${\mu}m$ 두께의 그린쉬트를 적층하고 동시소결하여 제작하였다. 제작한 다이어프램은 공동의 면적에 따른 센싱특성을 평가하기 위하여 각각 25, 49 $mm^2$의 두 종류를 제작하였다. 정전용량형 압력센서를 구현하기 위하여 상부에는 열증착기를 이용하여 Au 금속박막을 증착하였고 하부에는 상용 알루미늄막을 압착하였다. 압력에 따른 센싱특성을 평가하기 위하여 제작된 측정시스템을 이용하여 0~30 psi의 압력을 가변하여 압력센서의 정전용량 변화를 측정한 결과 두 센서 모두에서 선형적인 센싱 특성을 나타냄을 확인하였다.

A bond graph approach to energy efficiency analysis of a self-powered wireless pressure sensor

  • Cui, Yong;Gao, Robert X.;Yang, Dengfeng;Kazmer, David O.
    • Smart Structures and Systems
    • /
    • 제3권1호
    • /
    • pp.1-22
    • /
    • 2007
  • The energy efficiency of a self-powered wireless sensing system for pressure monitoring in injection molding is analyzed using Bond graph models. The sensing system, located within the mold cavity, consists of an energy converter, an energy modulator, and a ultrasonic signal transmitter. Pressure variation in the mold cavity is extracted by the energy converter and transmitted through the mold steel to a signal receiver located outside of the mold, in the form of ultrasound pulse trains. Through Bond graph models, the energy efficiency of the sensing system is characterized as a function of the configuration of a piezoceramic stack within the energy converter, the pulsing cycle of the energy modulator, and the thicknesses of the various layers that make up the ultrasonic signal transmitter. The obtained energy models are subsequently utilized to identify the minimum level of signal intensity required to ensure successful detection of the ultrasound pulse trains by the signal receiver. The Bond graph models established have shown to be useful in optimizing the design of the various constituent components within the sensing system to achieve high energy conversion efficiency under a compact size, which are critical to successful embedment within the mold structure.

소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현 (Telemetry capsule for pressure monitoring in the gastrointestinal tract)

  • 윤기원;우상효;이정현;문연관;박희준;원철호;김병규;최현철;조진호
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.211-218
    • /
    • 2005
  • As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.

Analysis of ICU Treatment on Resection of Giant Tumors in the Mediastinum of the Thoracic Cavity

  • Kang, Nai-Min;Xiao, Ning;Sun, Xiao-Jun;Han, Yi;Luo, Bao-Jian;Liu, Zhi-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권6호
    • /
    • pp.3843-3846
    • /
    • 2013
  • Objective: The purpose of this study was to assess prognosis after resection of giant tumors (including lobectomy or pneumonectomy) in the mediastinum. Materials and Methods: Patients with resection of a giant tumor in the mediastinum of the thoracic cavity received ICU treatment including dynamic monitoring of vital signs, arterial blood pressure and CVP detection, determination of hemorrhage, pulmonary function and blood gas assay, treatment of relevant complications, examination and treatment with fiber optic bronchoscopy, transfusion and hemostasis as well as postoperative removal of ventilators by invasive and non-invasive sequential mechanical ventilation technologies. Results: Six patients were rehabilitated successfully after ICU treatment with controlled postoperative errhysis and pulmonary infection by examination and treatment with fiber optic bronchoscopy without second application of ventilators and tubes after sequential mechanical ventilation technology. One patient died from multiple organ failure under ICU treatment due to postoperative active hemorrhage after second operative hemostasis. Conclusions: During peri-operative period of resection of giant tumor (including lobectomy or pneumonectomy) in mediastinum ofthe thoracic cavity, the ICU plays an important role in dynamic monitoring of vital signs, treatment of postoperative stress state, postoperative hemostasis and successful removal of ventilators after sequential mechanical ventilation.

Investigation in Influence of Screw Design on the MIM Process

  • Gornik, Christian
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.213-214
    • /
    • 2006
  • The results of investigations in screw design for metall injection molding (MIM) will be presented. The consistency of cavity pressure, metering time and MFQ (monitoring of feedstock quality; parameter measured during metering) was chosen to compare different screws. A simulation program was used to optimize the conveying and melting mechanisms in the plastification unit. The theoretical background of this simulation programm will be explained.

  • PDF