• 제목/요약/키워드: Cationic polyelectrolytes

검색결과 29건 처리시간 0.022초

지시약 적정법 및 분광광도법에 의한 양이온 고분자 전해질의 전해밀도 정량 (Charge Determination of Cationic Polyelectrolytes by Visual Titrimetry and Spectrophotometry)

  • 이민규;김상규
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.525-532
    • /
    • 2005
  • Polyelectrolyte titration, which was called colloid titration is based on the stoichiometric reaction between oppositely charged polyelectrolytes, This can be used, for instance, to determine the charge density of a cationic polyelectrolyte, using an anionic polyelectrolyte of known charge density, such as potassium polyvinyl sulfate (PPVS). The technique requires a suitable method of end-point detection and there are several possibilities. In this work, two methods have been investigated: visual titrimetry based on the color change of a cationic dye (o-toluidine blue, o-Tb) and spectrophotometry based on the absorbance change corresponding to the color change of the same dye. These have been applied to several cationic polyelectrolytes with different charge density and molecular weight. In all cases, the cationic charge was due to quaternary nitrogen groups. In the case of cationic dye, it was shown that the sharpness depends on the charge density of cationic polyelectrolyte. With the polyelectrolytes of lower charge density, the binding to PPVS is weaker and binding of the dye to PPVS can occur before all of the polyelectrolyte charge has been neutralized. However, by carrying out titrations at several polyelectrolyte concentrations, good linear relationships were found, from which reliable charge density values could be derived. Effects of pH and ionic strength were also briefly investigated. For cationic polyelectrolytes (copolymers of acrylamide and dimethylaminoethy] acrylate), there was some loss of charge at higher pH values, probably as a result of hydrolysis. Increasing ionic strength causes a less distinct color change of o-Tb, as a result of weaker electrostatic interactions.

Effects of Polyelectrolyte Dosage, Kaoline Particles and pH on Flocculation of Humic Acid by Catonic Polyelectrolytes

  • Kam, Sang-Kyu;Kim, Dae-Kyoung;Lee, Min-Gyu
    • 한국환경과학회지
    • /
    • 제12권8호
    • /
    • pp.861-870
    • /
    • 2003
  • Using a simple continuous optical technique, coupled with measurements of zeta potential, the effects of polyelectrolyte dosage, kaoline particles and pH on flocculation of humic acid by several cationic polyelectrolytes, have been examined. The charge density of a polyelectolyte is important in determining the optimum dosage and in the removal of humic acid. The optimum dosage is less for the polyelectrolytes of higher charge density and is the same regardless of the presence of kaoline particles of different turbidity. At the dosage, the removal of humic acid is higher for the polyelectrolytes of higher charge density and the zeta potential of humic acid approaches to near zero, With increasing pH of humic acid, the optimum dosage increases and the flocculation index value obtained at the dosage decreases in the following pH 7 > pH 5 > pH 9, regardless of polyelectrolytes.

고지재생연구 (제4보) -고분자 전해질이 KOCC 재생지료에 미치는 영향 (Recycling of Wastepaper(IV) -The effect of polyelectrolytes on recycled KOCC stock-)

  • 김정은;안인숙;류정용;신종호;송봉근;오세균
    • 펄프종이기술
    • /
    • 제31권1호
    • /
    • pp.23-30
    • /
    • 1999
  • The effects of polyelectrolytes and enzyme, alone and in combination, were investigated in OCC recycling system. Four types of the polyelectrolytes based on acrylamide, cationic and anionic monomers were applied to the enzyme-treated KOCC stock to improve the strength and drainage properties of testliner. The polyelectrolytes used in this work were designed in terms of molecular weight and charge density. The water conditions used for recycling were also varied. The results showed that the hydrolytic action of enzyme gave reduced surface area and amorphous region of fiber, and as a result, the cationic polymer was lost apparently its flocculating power due to the reduced bonding site of fiber surface. When the hardness and conductivity of water had been controlled to the conditins of OCC paper mill, the application of amphoteric polyelectrolyte to the enzyme-treated recycled stock was the most effective with respect to the strength and drainage properties of testliner.

  • PDF

간헐포기 소화 슬러지의 고분자 응집제에 의한 개량과 입도 분포 변화에 관한 연구 (A Study on the Conditioning with Polymer and the Particle Size Distribution of Intermittent Aerobic Digestion Sludge)

  • 김희준;김성홍;최재성
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.253-258
    • /
    • 2004
  • Synthetic organic polyelectrolytes can be used to condition sludges to enhance their dewaterability. Intermittent aerobic digestion is an useful digestion technology and has many advantages like neutral pH, low installation cost and easiness to operation. The objectives of this study were to investigate the dewaterability of intemittent aerobic digestion sludge and to find the relationship between dewaterability and particle size distribution change under the conditioning of intermittent aerobic digestion sludge by cationic polyelectrolyte. Digested sludge from intermittent aerobic digestion was used and cationic polyacrylamide polymer was added as a conditioner. CST(capillary suction time), TTF(time-to-filtration) were tested as a dewaterability index and the number of particle distribution was analyzed using particle size analyzer. The results indicate that cationic polyelectrolytes is useful to enhance dewaterability of intermittent aerobic digestion sludge. Mean particle diameter was increased as polymer dosage increased and its value was reached up to 100 mm on the condition of optimal cationic polymer dosage. CST and TTF are well correlated with mean particle diameter when the weighting order is 1.7. By the optimal conditioning with cationic polymer, particles in the filtrate are also reduced significantly and this means that conditioning is helpful to main stream by reducing SS loading from return flow.

고분자전해질의 LbL 흡착 처리에 의해 개질된 중질탄산칼슘의 특성 기초 연구 (Preliminary Study on Properties of Layer-by-Layer Assembled GCC with Polyelectrolytes)

  • 이제곤;류재호;심규정;안정언;이학래;윤혜정
    • 펄프종이기술
    • /
    • 제43권3호
    • /
    • pp.35-42
    • /
    • 2011
  • In this study, ground calcium carbonate (GCC) was modified by Layer-by-Layer (LbL) multilayering with polyelectrolytes. Cationic polyacrylamide (C-PAM) and poly sodium 4-styrene sulfonate (PSS) were used as cationic and anionic polyelectrolytes to modify GCC. The characteristics of the modified GCC were examined in terms of zeta potential and particle size with the addition level of polyelectrolyte and layer number. The GCC could form an assembly of cationic and anionic polyelectrolytes through consecutive adsorption process. The zeta potential of the modified GCC moved toward the cationicity and reached the plateau with the increase of the addition level of C-PAM. With layering of anionic PSS, the GCC had the negative charge. The particle size was dependent on the zeta potential. It was also observed by optical microscope. As the PSS was in the presence of the outermost layer, the GCC showed the better dispersability. It indicated that the surface charge and particle size can be controlled by adjusting the addition level of polyelectrolyte and the layer number.

셀룰로오스 나노피브릴 현탁액의 탈수성 평가 및 양이온성 고분자전해질 투입의 영향 (Evaluation of Dewatering of Cellulose Nanofibrils Suspension and Effect of Cationic Polyelectrolyte Addition on Dewatering)

  • 류재호;심규정;윤혜정
    • 펄프종이기술
    • /
    • 제46권6호
    • /
    • pp.78-86
    • /
    • 2014
  • Since cellulose nanofibrils (CNF) has large specific surface area and high water holding capacity, it is very difficult task to remove water from the CNF suspension. However, dewatering of CNF suspension is a prerequisite of following processes such as mat forming and drying for the application of CNF. In this study, we evaluated the drainage of cellulose fibers suspension under vacuum and pressure conditions depending on the number of grinding passes. Also, the effect of the addition of cationic polyelectrolyte on dewatering ability of CNF suspension was investigated. Regardless of dewatering condition, the total drained water amount as well as the drainage rate were decreased with an increase in the number of grinding passes. Pressure dewatering equipment enables us to prepare wet CNF mat with relatively higher grammage. The cationic polyelectrolytes improved the dewatering ability of CNF suspension by controlling the zeta potential of CNF. The fast drainage was obtained when CNF suspension had around neutral zeta potential.

Flocculation Characteristics of Kaoline Suspensions in Water by Cationic Polyelectrolytes

  • Kam, Sang-Kyu;Kim, Dae-kyoung;Ko, Byung-Churl;Moon, Chang-Seong;Lee, Min-Gyu
    • 한국환경과학회지
    • /
    • 제11권2호
    • /
    • pp.93-102
    • /
    • 2002
  • Using a simple continuous optical technique, coupled with measurements of zeta potential, the flocculation characteristics of kaoline suspensions of different content(15, 35 and 55 NTU) by several cationic polyelectrolytes, has been examined. The optimum mixing is obtained under a constant stirring of 200 rpm, differently from a general flocculation test. The charge density of a polyelectrolyte is important in determining the optimum dosage and in the removal of kaoline particles. The optimum dosage is less for the polyelectrolyte of higher charge density and is the same regardless of kaoline content. At the dosage, the removal of kaoline particles is higher for the polyelectrolyte of higher charge density and zeta potential of kaoline particles reaches to near zero. The rate of adsorption and flocculation rate have been found to be affected by charge density and molecular weight of a polyelelctrolyte and the content of kaoline particles.

전단 조건이 중질탄산칼슘의 무세척 고분자전해질 다층흡착 처리에 미치는 영향 (Effect of Shear Condition on Washless Polyelectrolytes Multilayering Treatment on GCC)

  • 이제곤;심규정;이학래;윤혜정
    • 펄프종이기술
    • /
    • 제46권5호
    • /
    • pp.51-60
    • /
    • 2014
  • To find a practical application approach of polyelectrolyte multilayering (PEM) on inorganic filler, we introduced PEM process without washing step and investigated the effect of shear condition on the washless PEM treatment of ground calcium carbonate (GCC). Washless multilayering on GCC was conducted under various shear conditions such as stirring, homogenization, and ultrasonication. Highly charged polyelectrolytes combination of polydiallyldimethylammonium chloride (PDADMAC) and poly sodium 4-styrene sulfonate (PSS) and low charged polyelectrolytes combination with cationic starch and anionic polyacrylamide (PAM) were compared. In the case of highly charged polyelectrolytes combination, shear conditions did not affect the zeta potential and the particle size of treated GCC. However, the modified GCC particles with low charged polyelectrolytes were more dispersed under higher shear condition while maintaining the zeta potential. In addition, GCC was successfully modified through laboratory inline washless polyelectrolyte multilayering system which consists of homogenizers and pumps.

무세척 고분자전해질 다층흡착 처리된 중질탄산칼슘이 종이의 품질에 미치는 영향 (Effect of Ground Calcium Carbonate Modified by Washless Multilayering of Polyelectrolytes on Paper Quality)

  • 이제곤;임완희;심규정;이학래;윤혜정
    • 펄프종이기술
    • /
    • 제47권4호
    • /
    • pp.115-126
    • /
    • 2015
  • In this study, we investigated influence of ground calcium carbonate (GCC) modified by washless multilayering of polyelectrolytes on paper quality. Three layers of polyelectrolytes (cationic starch/anionic polyacrylamide/cationic starch) were formed on the surface of GCC using laboratory inline washless polyelectrolytes multilayering system, which was called inline LbL GCC. Base papers were prepared with untreated GCC or inline LbL GCC using a laboratory handsheet former. These handsheets were coated with rod coater, and then printed by black ink. Properties of base paper and fold crack of coated paper were evaluated. Base paper with inline LbL GCC showed much higher mechanical strength in terms of tensile index, strain, internal bond strength, and folding endurance. The fold crack of coated paper with inline LbL GCC occurred more frequently compared to coated paper with untreated GCC. This might be due to highly improved internal bond strength of base paper, which resulted in smaller delamination that played a role of stress dissipation. It would be recommended to design a proper coating layer in order to prevent fold crack.

정수 슬러지의 탈수성 개선을 위한 고분자 응집제 조합주입 고찰 (Determination of Organic Polyelectrolyte Addition Method to Improve Dewaterbility of Alum Sludge)

  • 유태종;안균환;박상준;현미
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.608-618
    • /
    • 2004
  • Since polyelectrolytes have been used as conditioners, conventionally only a single polyelectrolyte has been added for sludge conditioning. However, the amount of polyelectrolyte needed for optimal conditioning of sludge is very critical. Overdosing reduces the sludge dewaterbility. In this experimental study, sludge conditioning with single or dual polyelectrolyte was conducted to avoid problems associated with overdosing. Single polyelectrolyte conditioning was conducted by one of cationic, nonionic, and anionic polyelectrolytes. The dual polyelectrolyte conditioning was performed by adding one polyelectrolyte and another one in sequence. The dewaterbility of sludges were measured by SRF(specific resistance to filtration), TTF(time to filter), CST(capillary suction time) respectively. Additionally, parameters such as turbidity, zeta potential, viscosity of conditioned sludges or supematant were measured to evaluate the changed characteristics of sludge by addition of polyelectrolytes. From the experiment results, it was concluded that single polyelectrolyte conditioning had a high probability of overdosing, whereas dual polyelectrolyte conditioning resulted in a better dewaterbility and less chance of overdosing. But, it was also found that dosing sequence in dual conditioning was very important according to the characteristics of sludge. Parameters such as viscosity, turbidity, zeta potential were found to be useful as a means of evaluating sludge dewaterbility.