• 제목/요약/키워드: Cation and anion concentration

검색결과 114건 처리시간 0.023초

Suppressed 이온 크로마토그래피에서 과량의 양이온이 낮은 농도의 음이온 분석에 미치는 영향 (The Effect of High Concentration Cation Matrix on the Analysis of the Low Anion Concentration in Suppressed Ion Chromatography)

  • 강미정;이석근
    • 분석과학
    • /
    • 제11권6호
    • /
    • pp.495-498
    • /
    • 1998
  • The effect of high concentration ion matrix on the analysis of low anion concentration in the suppressed ion chromatography was studied. The anions studied were $Br^-$, $NO_3{^-}$, $HPO_4^{2-}$, $SO_4^{2-}$, and $C_2O_4^{2-}$ in the presence of excess NaCl and $CaCl_2$. In this study we suggested that the erroneous results in the suppressed ion chromatographic determination of small concentration of anions were not caused by the interaction of large amount of cation in the suppressor, but by the interaction of cation with concerned anion in the original solution. The error in the analysis of such anion can not be eliminated just by dilution. Therefore, we suggested that standard addition method might be adequate for analyses of those samples.

  • PDF

비무장지대에 인접한 경기도 농촌지역 강수의 화학적 성분에 관한 기초 연구 (A Preliminary Study on the Chemical Compositions of Precipitation in the Rural Area of Kyunggi Province near Demilitarized Zone)

  • 박국태;김창호
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.157-164
    • /
    • 1998
  • preliminary study on the chemical compositions of forty seven precipitations from March 1994 to May 1995 In Yeoncheon-gun, which Is adjacent to the southern boundary of demilitarized zone (DMZ) in the northernmost tip of Kyunggi Province has been Performed. The metal cation and anion concentrations were measured by atomic absorption spectrometer and ion chromatography, respectively. pH/lon meter and direct nesslerization method were used for the concentration measurements of $H^+$ ion and $NH_46+$ ions, respectively Based on the data, the quantitative orders of the cation and anion average concentrations were $Ca^{2+}>NH_4^+>Na^+>K^+>Mg^{2+}>H^+ and SO_4^{2+}>Cl^-> NO_3^-$, respectively..The ratio of average total anion concentration to average total cation concentration was 0.97. The average pH value of the precipitations was 5.60. These results, correlation coefficients between the ion concentrations, and monthly variations of pH value and precipitation amount are used for chemical analysis on the environmental Pollution and Pollutant sources In Yeoncheon-gun of Kyunggi province near DMZ.

  • PDF

전해질 성분 및 농도, 이온교환 수지 비율에 따른 이온교환 특성 연구 (A Study on Ion Exchange Characteristics with Composition and Concentration of Electrolyte, Ratio of Ion Exchange Resin)

  • 안현경;이인형;윤형준;정현준
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.727-732
    • /
    • 2006
  • 본 연구에서는 전해질 성분 및 농도, 이온교환 수지 조성비율을 통해 이온교환 수지탑의 성능을 평가하고, 이온교환 수지에 의한 입자성 물질 제거의 능력과 입자성 물질이 이온교환 특성에 미치는 영향을 조사하였다. 이온교환 수지탑 배열 순서에 따라 파과(돌파)시점이 연장되며, 파과(돌파)순서는 음이온의 경우 $Cl^{-}, 양이온의 경우 $Na^{+} 순 이였으며, 전해질의 농도가 증가할수록 파과시간이 단축되었다. 이온교환 수지의 조성비 변화에서는 양음이온교환 수지 조성비가 1:2의 경우 1:1및 1:3의 경우보다 파과(돌파)시간이 연장되었으며 동일한 전해질 농도에서 입자 농도가 증가하면 20% 미만으로 파과(돌파)시간이 단축되었다. 양이온 교환수지 비율이 높으면 양이온의 파과(돌파)시점이 늦어져 이온교환 수지탑의 수명이 연장되고, 입자성 물질은 전해질 농도와 무관하게 이온교환 수지의 세공을 막아 이온교환 용량을 감소시켜 파과(돌파)시간을 단축시키는 것으로 조사되었다.

  • PDF

唐津과 安眠島地域 降水 成分의 變化特性에 關한 硏究 (A Study on the Transition Characteristics of Precipitation Components in Dangjin and Anmyon-do Area)

  • 정진도;이천호
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.593-601
    • /
    • 2004
  • In this study, we are going to compare the chemical composition of the precipitation that falls in the Dangjin and Anmyon-do areas by analyzing the water soluble components (anion and cation). We also examined the effects of seasonal change and regional difference in those data sets. The [$NO_3\;^- \;+\;SO_4\;^{2-}$] at 49.2${\mu}$eq/l is 67% of the total anion of 73.1${\mu}$eq/l, while that of [$NH_4\;^+\;+\;Ca^{2+}$] at 37.7${\mu}$eq/l is 62% of the cation in Dangjin area. Also, the [$NO_3\;^-\;+\;SO_4\;^{2-}$] concentration of 151.8 (${\mu}$eq/l) is 62% for the total anion of 143.5 (${\mu}$eq/l), and the [$NH_4\;^+\;+\;Ca^{2+}$] concentration of 119.7 (${\mu}$eq/l) is 47% for the cation of 254.3 (${\mu}$eq/l) in Anmyon-do area. The ion composition ratio is shown for the order by 22% of $SO_4\;^{2-}$, 20.8% of $NH_4\;^+$ and 15.4% of $Cl^-$ that is the sum of 58.7% for the total ion composition in Dangjin area, and is the order by 33.8% of $NH_4\;^+$, 16.3% of $SO_4\;^{2-}$ and 11.1% of $Cl^-$ in Anmyon-do area. Furthermore, We predicted that even areas which were previously clean will get acid rain if there is large scale construction there or nearby.

제주도에서의 빗물 이온 농도 분석 (Analysis of Rainwater Samples in Cheju)

  • 심상규;강창희;김용표
    • 한국대기환경학회지
    • /
    • 제10권2호
    • /
    • pp.98-104
    • /
    • 1994
  • Precipitation samples were collected at Kosan, Cheju Island over a period of 6 months An automatic rain sampler was manufactured domestically and installed at Kosan station. All samples were collected on a weekly basis. Samples were analyzed for S $O_4$$^{=}$, N $O_3$$^{[-10]}$ , C $l^{[-10]}$ , N $H_4$$^{+}$, N $a^{+}$, $K^{+}$, $Ca^{++}$, $Mg^{++}$, and pH and specific conductivity. The quality analysis of rain sample data were performed based on ion balance and specific conductivity. The pH of rain samples ranged between 4.6 to 6.6. Bicarbonate ion concentration were included in ion balance and specific conductivity calculations. The sum of cation concentrations were slightly greater than the sum of anion concentrations. Calculated specific conductivity was greater than measured specific conductivity. The most probable explanations for this discrepancy is "an anion too low or anion missing." Two criteria were used to identify outliners. They are 1) the difference between the sum of anion concentrations and cation concentration is more than 50 $\mu$eq./1 and 2) the difference between calculated and measured specific conductivity is more than 25%. Chemical analysis from several samples did not satisfy these quality control criteria. Volume weighted average concentrations were calculated. Dominant free acids in rain samples were N $a^{+}$, C $l^{[-10]}$ , S $O_4$$^{=}$, N $O_3$$^{[-10]}$ ions in order of abundance. Non-seasalt sulfate comprises 76% of total sulfate.sulfate.e.ate.e.

  • PDF

Effects of dietary cation and anion difference on eating, ruminal function and plasma leptin in goats under tropical condition

  • Nguyen, Thiet;Chanpongsang, Somchai;Chaiyabutr, Narongsak;Thammacharoen, Sumpun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권6호
    • /
    • pp.941-948
    • /
    • 2020
  • Objective: This study was carried out to determine the effects of elevated dietary cation and anion difference (DCAD) on dry matter intake (DMI) and ruminal fermentation pattern in lactating dairy goats under tropical conditions. Methods: Ten dairy goats were divided into two groups of five animals each. The groups received diets at different DCAD levels, either a control diet (22.81 mEq/100 g dry matter [DM], DCAD-23) or a DCAD-39 diet (39.08 mEq/100 g DM, DCAD-39). After parturition, DMI and water intake were recorded daily. Ruminal fluid and urine were collected, and nutrient digestibility measurements were carried out at 8th weeks postpartum (PP-8). Blood samples were collected at PP-4 and PP-8 to measure plasma leptin. Results: Dry matter intake/body weight (DMI/BW) at PP-8 of the animals fed the DCAD-39 diet was significantly higher than those fed with DCAD-23 diet (p<0.05). Animals fed with DCAD-39 consumed more water than those fed DCAD-23 over 24 h, particularly at night (p<0.05). Ruminal pH, acetate concentration, and urinary allantoin excretion increased with the DCAD-39 diet, whereas ruminal butyrate concentration was lower with the DCAD-39 diet. On the other hand, other ruminal parameters, such as total volatile fatty acid concentration, propionate molar proportion and acetate/propionate average ratio, were not affected by increased DCAD supplementation. Apparent digestibility was improved by increased DCAD supplementation. Plasma leptin concentration was higher with DCAD supplementation. Conclusion: When feeding goats with DCAD-39 under tropical conditions, an increase in DMI was associated with improved apparent digestibility of nutrients, ruminal fermentation and microbial protein synthesis. An increase in plasma leptin concentration could not explain the effect of high DCAD on DMI.

Evaluation of the Nitrate Anion in Recon Extract by Adsorbents

  • Han, Young-Rim;Sung, Yang-Joo;Park, Jin-Won;Kim, Yang-Ok;Rhee, Moan-Soo
    • 한국연초학회지
    • /
    • 제29권2호
    • /
    • pp.104-109
    • /
    • 2007
  • The amount of nitrate in the tobacco leaf has been shown to be correlated with the levels of alkaloids and nitrosamines. Also the nitrate content of the tobacco correlated closely with the smoke delivery of nitric oxide and tobacco-specific nitrosamines (TSNAs). These are related with the effect of the reconstituted tobacco leaf(Recon) using the tobacco stems. Adsorption process is gaining interest as one of the effective processes of advanced liquid treatment for liquid containing unnecessary materials. This study is focused on the evaluation of four anion exchangers, a cation exchanger and an activated carbon, as adsorbents for reduction of nitrate anion from Recon extract. In order to analyze the nitrate anion, the IC method used in this work was carried out with a Dionex ICS-2000 system. The effects of dosages of adsorbents and concentration of extract on the removal of nitrate anion were examined. Experimental results showed that for nitrate-anion exchanger, nitrate-cation exchanger and nitrate-activated carbon adsorption system, approximately 70 %, 10 %, and 4 % removal efficiencies were achieved at the Brix 10 and the 20 % addition. Although the activated carbon was little efficient for removal of nitrate ion, the removal of nicotine was very efficient at given conditions.

The Effects of Resin Ratio and Bed Depth on the Performance of Mixed-bed Ion Exchange at Ultralow Solution

  • Yoon, Tae-Kyung;Lee, Gang-Choon;Noh, Byeong-Il
    • 한국환경과학회지
    • /
    • 제18권6호
    • /
    • pp.595-601
    • /
    • 2009
  • The effects of the cation-to-anion resin ratio and bed depth on ion exchange performance of mixed-bed were studied at ultralow solution concentration. Breakthrough curves were experimentally obtained for NaCI solution as functions of resin ratio and bed depth. The bed depth affects the pattern of the sodium breakthrough curve but not the chloride breakthrough curve in beds because of the selectivity difference. Resin selectivity determines the shape of breakthrough curves, Some sodium and chloride breakthrough curves crossed at a point as a function of resin ratio. The lower cation-to-anion resin ratio showed the higher effluent concentration or treated volume of the crossover point regardless of the total resin weight.

Poly(1-methyl-4-vinylpyridium iodide-co-styrene)막을 통한 유기음이온의 투과특성 (Transport Characteristics of Organic Anions through Poly (1-methyl-4vinylpyridium iodide-co-styrene) Membrane)

  • 이광재;한정우박돈희조영일
    • KSBB Journal
    • /
    • 제6권2호
    • /
    • pp.207-213
    • /
    • 1991
  • In this study poly (1-methyl-4-vinylpyridinium iodide-co-styrene) membrane with pyridinium cation as a fixed carrier was synthesized and the transport characteristics of the membrane was examined over various factors. As the concentration of the fixed carrier in the membrane was increased, the water content was increased. Meanwhile, the counter current of the organic anion and the chloride ion, the following results were obtained. Initial flux of Cl-, organic anion and Na+ decreased with the increasing thickness of membrane, and as the concentration of the fixed carrier increases, the initial flux of Cl- and organic anion increase but the initial flux of Na+ decreased. The flux equation of the organic anion, CCl3COO- was obtained from saturation kinetics as follows;$V_{o}=\frac{(8.67{\times}10^{-5}){\cdot}[NaCl]}{9.63{\times}10^{-2}+[NaCl]} mol/cm^2h$

  • PDF

초저이온 농도범위에서 혼합층 이온교환능과 온도의 영향 - 2. 온도의 영향 - (The Mixed-Bed Ion Exchange Performance and Temperature Effects at Ultra-Low Concentrations - 2.Temperature Effects -)

  • 윤태경;노병일;이창원;문병현;이강춘;조명찬
    • 공업화학
    • /
    • 제10권2호
    • /
    • pp.206-211
    • /
    • 1999
  • 본 연구에서는 NaCl수용액의 초저이온 농도범위 ($1.0{\times}10^{-4}M$ 이하)에서 양이온 교환수지 대 음이온 교환수지의 비, 수지량, 계의 온도를 함수로 한 혼합층 이온교환의 거동을 실험적으로 연구하였다. 실험실 크기의 연속흐름 칼럼을 통하여 양이온 교환수지와 음이온 교환수지의 교환능이 소모될 때까지의 유출농도를 처리된 유량의 함수로 측정하여 파과곡선을 구하였다. 초기누출은 수지량이 적은 경우 양이온과 음이온의 파과곡선에 나타났으나, 선택도계수가 낮은 양이온의 파과곡선에 현격하게 크게 나타났다. 선택도계수는 파과곡선의 기울기에 영향을 미쳤으며, 계수값이 큰 음이온의 파과곡선의 기울기가 급격하였다. 온도변화는 파과곡선의 기울기에 영향을 미쳤으며, 온도가 증가할수록 이온교환속도가 증가하였다. 이 온도효과는 수지비에 관계없이 수지총량이 증가할수록 또는 이온교환수지의 교환능이 감소하여 파과곡선이 평형에 가까워질수록 감소하였다.

  • PDF