• 제목/요약/키워드: Cathodic current process

검색결과 60건 처리시간 0.033초

CHARACTERISTICS OF PLATED GOLD LAYER ON ANSI 304 STAINLESS STEEL ACCORDING TO THE VARIATION OF PRETREATMENTS AND ELECTROLYSIS CONDITIONS

  • Lee, Dong-hun;Lee, Jae-Bong
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.224-234
    • /
    • 1999
  • An attempt was made to characterize the relationship between pretreatment processes, electrolysis conditions and behaviors of the plated gold layer. In order to investigate the effect of pretreatment processes on plating, rest potential measurements of various pretreated stainless steels and a.c.-impedance spectroscopy tests were carried out in the strike plating solution. Characteristics of plated gold layers and adhesions between plated gold layers and stainless steel substrates were examined by scratching tests and micro-Vickers hardness tests. The result shows that the strike plating enhanced the adhesion of interface, the cathodic electro-activation pretreatment process improving both corrosion resistance and adhesion strength. The preferred orientations of plated gold layers were examined by the X-ray diffraction technique. As the current density increases, [111] preferred orientation of plated gold layers was found to become well developed.

  • PDF

Kinetic Study of the Electrooxidation of Mefenamic Acid and Indomethacin Catalysed on Cobalt Hydroxide Modified Glassy Carbon Electrode

  • Saghatforoush, Lotfali.;Hasanzadeh, Mohammad.;Karim-Nezhad, Ghasem.;Ershad, Sohrab.;Shadjou, Nasrin.;Khalilzadeh, Balal.;Hajjizadeh, Maryam.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권6호
    • /
    • pp.1341-1348
    • /
    • 2009
  • Electrocatalytic oxidation of two anti-inflammatory drugs (Mefenamic acid and Indomethacin) was investigated on a cobalt hydroxide modified glassy carbon (CHM-GC) electrode in alkaline solution. The process of oxidation and its kinetics were established by using cyclic voltammetry and chronoamperometry techniques as well as steady state polarization measurements. Voltammetric studies indicated that in the presence of under study drugs, the anodic peak current of low-valence cobalt species increased, followed by a decrease in the corresponding cathodic current. This result indicates that the drugs were oxidized via cobalt hydroxide species immobilized on the electrode surface via an E$\acute{C}$ mechanism. A mechanism based on the electrochemical generation of Co (IV) active sites and their subsequent consumption by the drugs in question was also investigated. The constants rate of the catalytic oxidation of the drugs and the electron-transfer coefficients reported.

압력용기용 Cr-Mo강의 수소취화 특성 (The Characteristics of the Hydrogen Embrittlement for the Cr-Mo Steels in Use of Pressure Vessel)

  • 이휘원;양현태;김상태
    • 대한기계학회논문집A
    • /
    • 제26권6호
    • /
    • pp.1107-1113
    • /
    • 2002
  • This study presents the hydrogen emblittlement in the metal, which decreases the ductility and then induces the brittle fracture. The contribution deals with the effect of strain rate and notch geometry on hydrogen emblittlement of 1.25Cr-0.5Mo and 2.25Cr-1Mo steels, which are in use at high pressure vessel. Smooth and notched specimens were examined to obtain the elongation and tensile strength. For charging the hydrogen in the metal, the cathodic electrolytic method was used. In this process, current density is maintained constant. The amount of hydrogen penetrated in the specimen was detected by the hydrogen determenator(LECO RH404) with the various charging time. The distribution of hydrogen concentration penetrated in the specimen was obtained by finite element analysis. The amount of hydrogen is high in smooth specimen and tends to concentrate in the vicinity of surface. The elongation and tensile strength decreased with the passage of charging time in 1.25Cr-0.5Mo and 2.25Cr-1Mo steels. The elongation increased and tensile strength decreased as strain rate increased. As a result of this study, it is supposed that 1.25Cr-0.5Mo steel is more sensitive than 2.25Cr-lMo steel in hydrogen embrittlement. Hydrogen embrittlement susceptibility of notched specimen after hydrogen charging is more remarkable than that of smooth specimen.

산화피막전극을 이용한 디이소부틸니트로소아민의 전극반응 (Reactivities of Di-iso-butylnitrosoamine by Anodic Film Formed on Metals)

  • 황금소
    • 한국수산과학회지
    • /
    • 제14권2호
    • /
    • pp.94-102
    • /
    • 1981
  • 해수에서 전기 전도성이 있는 산화 피막전극을 사용하여 금속 산화피막 전극들의 특성과 발암성 원인물질인 DBNA의 전극 반응성을 규명하는데 필요한 기초자료를 potential drop방법과 galvanostatic방법으로 얻어서 다음과 같은 결론을 내렸다. 1) $9\%_{\circ}$해수에 음극반응 억제제 DBNA를 첨가한 경우 알루미늄 산화피막 전극과 아연 산하피막 전극은potential drop현상을 나타내지 못 했으나 납 산화피막 전극과 구리 신화피막 전극은 피막전극으로서 적합한 기능을 가졌음을 알았다. 2) 제1단계 음극반응의 transition time이 $0.22\sim1.40sec$범위의 1분이내 값이므로 산화피막을 통과한 양성자는 확산$\rightarrow$흡착과정의 음극반응을 했다. 3) 0.5M NaCl수용액과 $9\%_{\circ}$해수에서 얻어진 transition time 값들이 대체로 일치한 것은 금속의 종류에 관계없이 산화피막을 통과한 양성자의 확산속도가 인정전류밀도 범위에서 인정하였기 때문이다. 4) $1.9\times10^{-4}\sim5.0\times10^{-6}\;amp/cm^2$의 전류밀도 범위에서 해수와 해수에 억제제 DBNA를 첨가했을때 얻어진 $\tau_{1}/4$값들의 $E_{1}/4$값들의 차가 각각 0.06sec와 0.53v있으므로, 억제 DBNA의 음극반응은 주로 흡착$\rightarrow$확산과정 이었다. 5) 알루미늄 산화피막과 아연 산화피막의 표면에 흡착된 전재질의 흡착량이 납 산화피막과 구리 산화피막보다 많은 것은 피막표면에 생성된 불규칙한 기공 생성 수가 증가하였기 때문이다.

  • PDF

$KNO_3$$HNO_3$ 전해액이 Cu에 미치는 영향 (Effect of copper surface to $HNO_3$ and $KNO_3$ electrolyte)

  • 서용진;한상준;박성우;이영균;이성일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.486-486
    • /
    • 2009
  • In this paper, the current-voltage (I-V) curves, such as linear sweep voltammetry (LSV) and cyclic voltammetry (CV), were employed to evaluate the effect of electrolyte concentration on the electrochemical reaction trend. From the I-V curve, the electrochemical states of active, passive, transient and trans-passive could be characterized. And then, we investigated that how this chemical affect the process of voltage-induced material removal in electrochemical mechanical polishing (ECMP) of Copper. The scanning electron microscopy (SEM) and energy dispersive spectroscopy EDS) analyses were used to observe the surface profile. Finally, we monitored the oxidation and reduction process of the Cu surface by the repetition of anodic and cathodic potential from cyclic voltammetry (CV) method in acid- and alkali-based electrolyte. From these analyses, it was important to understand the electrochemical mechanisms of the ECMP technology.

  • PDF

Effect of Zincate Treatment Time on Dissolution Behavior and Deposition of Copper on AZ31 Mg alloy in Pyrophosphate Bath

  • Van Phuong, Nguyen;Moon, Sungmo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.194.1-194.1
    • /
    • 2016
  • The present study investigated the effect of zincate treatment time on the dissolution behavior and the deposition of copper by immersion process and electroplating process on AZ31 Mg alloy substrate in a copper pyrophosphate bath. Without zincate pretreatment, the AZ31 Mg substrate quickly dissolved in the copper pyrophosphate solution although an external cathodic current was applied. The copper layers deposited on non-zincate treated AZ31 Mg alloy substrate by both immersion and electroplating processes showed very porous structure and very poor adhesion. With increasing zincate treatment time up to 2 min, the dissolution of AZ31 substrate in pyrophosphate solution rapidly decreased and the deposited copper layer was less porous and exhibited stronger adhesion. The immersion of AZ31 Mg sample in zincate solution for 5 min was found as a critical time for producing a non-porous and adherent electrodeposited copper layer on AZ31 Mg alloy. The optimum zincating time can be determined by observing the open circuit potential (OCP) of AZ31 Mg alloy samples in a copper pyrophosphate electroplating bath. The OCP reached a stable value of about -0.10 V (vs. SCE) after 5 min of immersion in the copper pyrophosphate electroplating solution.

  • PDF

사용후핵연료 전기환원 공정에서의 알카리, 알카리토 금속 산화물들의 거동 분석 (Analysis of AM and AEM Oxides Behavior in a SF Electrolytic Reduction Process)

  • 박병흥;강대승;서중석;박성원
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.268-277
    • /
    • 2004
  • 사용후핵연료 차세대 관리공정의 주된 단위 공정인 전기 환원에 의한 금속 전환 공정에서의 핵종 거동 및 분포에 관한 기초 연구의 일환으로 고방열성 핵종인 알카리, 알카리토 금속 산화물들의 고온 용융염에서의 전기 화학적 특성을 측정 분석함으로서 전기 환원 공정에서의 거동을 예상하였다. LiCl-$Li_2O$ 용융염계에서 Cs, Sr 및 Ba은 Li 보다 높은 진위에서 환원되며 환원 전위는 서로 근접해 있는 것으로 측정되었다. 이에 따라 사용후핵연료의 전기 환원 과정에 Li 환원을 매개로 한 반응 메카니즘에 저해를 일으키지 않을 것으로 예측되었다. 알카리, 알카리토 금속의 환원조건에서 공정이 운전될 경우 자유에너지 변화의 계산을 통해 알자리, 알카리토 금속이 용융염으로 재순환됨을 확인 하였으며 전류 범위에 따른 금속 원소의 농도 변화를 측정하여 알카리, 알카리토 금속의 물질 전달에 대한 전류의 영향을 평가하였다.

  • PDF

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2000년도 추계학술발표회 초록집
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

NiO/YSZ/Pt 전해셀의 고온 수증기 전해에 의한 수소제조 특성 (Hydrogen Production by the High Temperature Steam Electrolysis of NiO/YSZ/Pt Cell)

  • 유지행;김영운;이시우;서두원;홍기석;한인섭;우상국
    • 한국수소및신에너지학회논문집
    • /
    • 제17권1호
    • /
    • pp.62-68
    • /
    • 2006
  • High temperature electrolysis is a promising technology to produce massively hydrogen using renewable and nuclear energy. Solid oxide fuel cell materials are candidates as the components of steam electrolysers. However, the polarization characteristics of the typical electrode materials during the electrolysis have not been intensively investigated. In this study, NiO electrode was deposited on YSZ electrolyte by spin coat process and firing at $1300^{\circ}C$. Pt electrode was applied on the other side of the electrolyte to compare the polarization characteristics with those by NiO during electrolysis. The $H_2$ evolution rate was also monitored by measuring the electromotive force of Lambda probe and calculated by thermodynamic consideration. At low current density, Pt showed lower cathodic polarization and thus higher current efficiency than Ni, but the oxidation of Ni into NiO caused the increase of anodic resistance with increasing current density. High overpotential induced high power consumption to produce hydrogen by electrolysis.

An Investigation of Mild Steel with Nitrogen-containing Inhibitor in Hydrochloric Acid

  • Horng, Y.T.;Tsai, Yi-Liang;Tu, Ching-Fang;Lee, Chien-Ming;Wei, F.I.;Shih, H.C.
    • Corrosion Science and Technology
    • /
    • 제2권5호
    • /
    • pp.233-237
    • /
    • 2003
  • Pickling inhibitors can be used to form an adsorbed layer on the metal surface to hinder the discharge of H^+$ and dissolution of metal ions. Nitrogen-containing inhibitors were selected as corrosion inhibitors for mild steel (MS) in pickling acid process. In this study, the addition of inhibitor, the pickling temperatures and the pickling times were the parameters to investigate the effects on the inhibition efficiency (IE) for MS by using weight loss measurement. Preliminary results show that the IE increased with the increase in pickling time from 10 minutes to 60 minutes, and the IE also increased with the increase in temperature at room temperature and $40^{\circ}C$. At the higher temperature. the IE values are higher and almost independent with the pickling time. Furthermore, the potentiodynamic polarization, open circuit corrosion potential-time and corrosion current-time studies show that nitorgen-containing inhibitor behaves predominantly as cathodic polarization. The roughness test and SEM investigation are also studied in this paper.