• Title/Summary/Keyword: Catheters

Search Result 239, Processing Time 0.024 seconds

Shape Prediction Method for Electromagnet-Embedded Soft Catheter Robot (전자석 내장형 소프트 카테터 로봇 형상 예측 방법)

  • Sanghyun Lee;Donghoon Son
    • The Journal of Korea Robotics Society
    • /
    • v.19 no.1
    • /
    • pp.39-44
    • /
    • 2024
  • This study introduces a novel method for predicting the shape of soft catheter robots embedded with electromagnets. As an advancement in the realm of soft robotics, these catheter robots are crafted from flexible and pliable materials, ensuring enhanced safety and adaptability during interactions with human tissues. Given the pivotal role of catheters in minimally invasive surgeries (MIS), our design stands out by facilitating active control over the orientation and intensity of the inbuilt electromagnets. This ensures precise targeting and manipulation of the catheter segments. The research encompasses a comprehensive breakdown of the magnetic modeling, tracking algorithms, experimental layout, and analytical techniques. Both simulation and experimental results validate the efficacy of our method, underscoring its potential to augment accuracy in MIS and revolutionize healthcare-oriented soft robotics.

The Central Venous Catheter-related Infection of Chlorhexidine-silver Sulfadiazine Coated Catheters in Medical ICU (내과계 중환자실 환자에서 Chlorhexidine-silver Sulfadiazine Coated Catheter의 중심정맥관 감염에 대한 연구)

  • Jung, Young Ju;Koh, Younsuck;Lim, Chae-Man;Lee, Jae Seung;Yu, Mi Hyun;Oh, Yeon Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.389-396
    • /
    • 2005
  • Background : Central venous catheters(CVCs) area major source of nosocomial infection. Chlorhexidine-silver sulfadiazine coated catheters (CHSS) were developed to reduce the rate of CVC infection. However, the clinical effectiveness of CHSS in comparison wth non-coated catheter (NCC) remains to be evaluated. Methods : From January 2004 to December 2004 in medical intensive care unit (ICU) of Asan Medical Center, CVCs were inserted in 446 cases. We retrospectively analyzed characteristics of patients and catheterization,the catheter-related infection rate and colonization, microbiologic findings, and insertion sites (subclavian, jugular, femoral) according to the type of inserted CVCs (NCC: 187 cases, CHSS: 259 cases). Catheter related infection is defined as catheter related bacteremia and catheter related non-bacteremic sepsis. Results : 1) The mean age of the patients in each group was $62{\pm}16$ years, $63{\pm}15$ years (p=0.42), and sex ratio 94:50, 141:69 (p=0.9) in NCC and CHSS. Duration of ICU admission ($29{\pm}37$, $26{\pm}44$ p=0.42), duration of mechanical ventilation ($17{\pm}22$, $15{\pm}19$ p=0.17), and APACHE III score at the time of CVC insertion ($81{\pm}34$, $82{\pm}37$ p=0.61) were not different between both groups. 2) Mean duration of catheterization was 118 in NCC and 119 in CHSS (p=0.98). Number of catheter-days was 2176 days in NCC and 3035 days in CHSS. Catheter-related infection occurred in 9 (4.8%) cases receiving NCC and 4 cases (1.5%) receiving CHSS. Catheterrelated infection incidence per 1000 catheter-days was 4.1 and 1.3, respectively (p=0.04). CHSS was associated with a significant reduction of infection in jugular catheters regarding to insertion sites (p=0.01). 3) Microorganisms causing infection were Staphylococcus aureus (n=3), Candida (n=3), coagulase-negative Staphylococci (n=2), and Klebsiella (n=1) in NCC, and Candida species (n=2), coagulase-negative Staphylococci (n=2), Proteus (n=1) in CHSS. Conclusion : CHSS has significantly reduced the episodes of infection compared to NCC in jugular catheterization in medical ICU.

Consideration on Domestic Production of Materials and Consumables for Human IVF-ET Program (체외수정 및 배아이식술 관련 재료 및 소모품의 국산화 필요성에 대한 고찰)

  • Cha, Byung-Hun;Jun, Jin-Hyun
    • Development and Reproduction
    • /
    • v.15 no.4
    • /
    • pp.385-391
    • /
    • 2011
  • Human in vitro fertilization and embryo transfer (IVF-ET) program is a general procedure for infertile couples since first successful delivery on 1978 in UK and Korean first on 1985. Recently in Korea, more than 42,000 cases per year of IVF-ET were performed and showed good pregnancy rates compared worldwide data. The human IVF-ET procedure use many consumables, such as ovum pick-up (OPU) needles, centrifuge tubes, culture dish, ICSI pipette, culture media and ET catheters. Major of these materials are supported by the global companies. Thus, Korean IVF-ET program might be placed unstable situation by global economical risks. These uncertain problems could be overcome by the domestic production of IVF-ET materials and consumables. Two times questionnaires for Korean clinicians and researchers about the domestic production were performed and analyzed. Many of them requested domestic OPU needles, ET catheters, culture media and ICSI pipettes under good quality control and quality assurance system. This trial may be contributed to industrialization and to global competence of Korean IVF-ET program. The results of this survey can be provide a fundamental base for development and production of domestic materials and consumables for human IVF-ET program.

A Study on the Activities of IV Team In the Children's Hospital (소아병원의 정맥주사팀 활동에 대한 조사연구)

  • Hwang, Jeong Hae;Hwang, Jee In;Kim, Mi Ran;Shin, Hee Young;Ahn, Hyo Seop
    • Quality Improvement in Health Care
    • /
    • v.6 no.1_2
    • /
    • pp.92-106
    • /
    • 1999
  • Background : In many university hospitals, intravenous(IV) therapies and samplings had been one of the most important works of doctors who are in training. However, recently as patient oriented care is becoming more weighted for qualified health service IV therapies should be the works of specialized personnels. This study was conducted to investigate the medical staff's perception on IV team, to survey patient or parent's expectation on IV team, and to assess the frequency of IV therapy related complications and the characteristics of phlebitis among the hospitalized children. Methods : We collected data prospectively before the start of IV team from February 22 to February 29. 1999 and from September 27 to October 3, 1999, 6 months after beginning of IV team at Seoul National University Children's Hospital. IV team started their activities from March 1, 1999. General pediatric wards were not included for the IV and sampling team and oncology ward and surgical units were all included for the IV and sampling team's work. IV specialist was the well trained nurse who had been working in the field of pediatrics especially for the oncology patients. The subjects of this study were medical staffs who were working in children's hospital as doctors in training and patients who were treated with IV therapies in children's hospital during the same period. Results : Doctors responded that IV team need to be organized for IV care and expected IV team could reduce their work load. Parents of patients also responded IV team was very improtant to perform high quality IV care. They had willingness to pay extra charge for IV team care. In the wards where IV team did not work, they used various kinds and sizes of catheters, but in the wards where IV team worked, they needed just one or two types of catheters. As the exact role of IV team is not still established, job description is needed between the IV team and medical doctors. In the aspects of medical costs. it could save the materials for the IV also. Conclusion : This study showed that IV team could increase patient's satisfaction with decrease of medical doctors work load and concomitantly could save the costs of IV materials. And for the expansion of the IV team, job description is needed and for the total care of the children IV specialist and sampling team should expand their roles.

  • PDF

Absorbed Dose for the Endovascular Ho-166-DTPA Brachytherapy Using a Balloon Angio Catheter (풍선도자관의 Ho-166-DTPA 흡수선량)

  • 조철우;박찬희;윤석남;강해준;김미화;장지선;박경배
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.98-103
    • /
    • 2002
  • The purpose of this study was to evaluate the absorbed dose to the coronary artery segment from various sized balloon angio catheters. The liquid form of Ho-166 was produced at the KAERI by (n, ${\gamma}$ ) reaction. We used GafChromic film for the estimation of the absorbed dose by beta particles. The exposed films were read using a videodensitometer. Several film exposures were made with varying irradiation times and activities. A modified micrometer was used for the measurement of the absorbed dose distribution near the balloon surface. Four balloons of coronary catheters evaluated were 30 m long and 2.5, 3.0, 3.5 and 4.0 mm in diameter. All doses are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 0.86, 1.01, 1.11 and 1.24 Gy/min/GBq/ml at a balloon surface for various balloon diameter 2.5, 3.0, 3.5 and 4.0 mm respectively. Using a vacuum pump, the air in the balloon was evacuated prior to instillation of the Ho-166 source. By removing air bubbles in the balloon, the absorbed dose distribution was more uniform.

  • PDF

Needle Decompression for Trauma Patients: Chest Wall Thickness and Size of the Needle (외상 환자에 대한 바늘감압술에서 흉벽 두께와 바늘 길이의 관계)

  • Kim, Jee-Wan;Jeong, Jin-Woo;Cho, Suck-Ju;Yeom, Seok-Ran;Han, Sang-Kyoon;Park, Sung-Wook
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2010
  • Purpose: A tension pneumothorax is a fatal condition that requires immediate intervention. Although a definitive treatment for a tension pneumothorax is a tube thoracostomy, needle decompression can provide temporary relief, that is lifesaving. The traditional procedure for needle decompression involves inserting a needle or catheter at the second intercostal space, the midclavicular line. Recent evidence suggests that the commonly used catheters do not have sufficiently penetrate the chest wall. There are also claims that a lateral approach to needle decompression is easier and safer than the traditional anterior approach. The purpose of this study is to evaluate the optimal approach for needle decompression for the Korean population by measuring chest wall thicknesses at the points used for both the anterior and the lateral approaches. Methods: The chest wall thickness (CWT) of trauma victims who visited the Emergency Center of Pusan National University Hospital was measured by computed tomography (CT) images. The CWT was measured at the points used for the anterior and the lateral methods and was compared with the length of commonly used catheters, which is 45 mm. Results: The mean CWT at the second intercostal space, the midclavicular line, was shorter than the CWT at the 5th intercostal space, the anterior axillary line. However, the percentage of patients whose CWT was greater than 45 mm was larger when measured anteriorly (8.2%) that when measure laterally (5.7%). Female patients and those older than 60 were more likely to have an anterior CWT greater than 45 mm (28.2% for females and 15.5% for those older than 60). Conclusion: The percentage of trauma victims in Korea whose CWT is greater than 45 mm is lower than the values previously reported by other countries. However, females and older patients tend to have thicker chest walls, so the lateral approach would be suggested when performing needle decompression for such patients with suspected tension pneumothoraces.

Two Cases of Fractured and Embolized Implanted Central Venous Chemoports in Lung Cancer (폐암환자에서 발생한 피하매몰 중심정맥포트 골절 및 색전증 2예)

  • Ju, Jin Yung;Cho, Jae Yeong;Lim, Jung Hwan;Cho, Gye Jung;Chae, Dong Ryeol;Oh, In Jae;Kim, Kyu Sik;Kim, Yu Il;Lim, Sung Chul;Kim, Young Chul;Song, Sang Yoon;Na, Kook Ju;Kim, Yun Hyun;Kim, Jae Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.449-453
    • /
    • 2007
  • Totally implanted central venous access devices for chemotherapy (chemoport) are being used increasingly in lung cancer patients. Vascular catheters are associated with various complications including infection, thrombosis as well as spontaneous fractures and embolization of the catheter, which is known as 'pinch-off syndrome'. 'Pinch-off syndrome' refers to the compression of a subclavian central venous catheter between the clavicle and first rib resulting in an intermittent or permanent obstruction, which can lead to tears, transection, or embolization. We report two cases of fractured and embolized implanted subclavian venous catheters in which the fragments were removed percutaneously. A 62-year-old man presented with back pain with a duration of a few weeks. The chest radiograph revealed complete transsection and embolization of the catheter into the right atrium. In addition, a 47-year-old woman with a chemoport had a grade 3 pinch-off sign in a chest radiograph demonstrating complete transsection and embolization of the catheter into the pulmonary artery. Both cases were managed by retrieving the embolized distal fragment percutaneously and removing the proximal section of the catheter.

Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study

  • Song, Jun-Seop;Lee, Young-Seon;Hwang, Minki;Lee, Jung-Kee;Li, Changyong;Joung, Boyoung;Lee, Moon-Hyoung;Shim, Eun Bo;Pak, Hui-Nam
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.5
    • /
    • pp.507-514
    • /
    • 2016
  • Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in -silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: $11.5{\pm}0.7%$ variation, mini-cath: $7.1{\pm}1.2%$ variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: $r=0.3055{\pm}0.2194$ vs. mini-cath: $0.6074{\pm}0.0733$, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one ($38.3{\pm}4.6%$ vs. $22.3{\pm}1.4%$, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.

Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage (피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표)

  • Yim, Sin Gil;Oh, Min Suk;Lim, Jun Seob;Kang, Myung Gi;Kwak, Yeon Sang;Park, Seung Gyu;Song, Gyung Bae;Kim, Han Yung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF

Initial Experience of ACE68 Reperfusion Catheter in Patients with Acute Ischemic Stroke Related to Internal Carotid Artery Occlusion

  • Jang, Hyoung-Gyu;Park, Jung-Soo;Lee, Jong-Myong;Kwak, Hyo-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.545-550
    • /
    • 2019
  • Objective : Penumbra ACE68 reperfusion catheter is a new large bore aspiration catheter used for reperfusion of large vessel occlusion. The objective of this study was to investigate the efficacy of this catheter in comparison to that of previous Penumbra catheters in patients with acute ischemic stroke related to internal carotid artery (ICA) occlusion. Methods : Data of all eligible patients who received endovascular treatment (EVT) for ICA occlusion using Penumbra aspiration catheters between January 2015 and December 2018 were retrospectively reviewed. After dividing into two groups according to use of penumbra ACE68, baseline characteristics of patients, successful recanalization rate, puncture to recanalization time, and switch to stent base technique rate were assessed. Successful recanalization was defined by a thrombolysis in cerebral infarction (TICI) score ${\geq}2b$ and favorable functional outcome was defined according to modified Rankin scale (score, 0-2). Results : ACE68 reperfusion catheter was used in 29 of 75 eligible patients (39%). The puncture to recanalization time was significantly shorter ($26{\pm}18.2$ minutes vs. $40{\pm}24.9$ minutes, p=0.011) and the rate of switch to stent-based retrieval was significantly lower (3% vs. 20%, p=0.046) in ACE68 catheter group. Moreover, although not statistically significant, the successful recanalization rate was higher (83% vs. 76%, p=0.492) in ACE68 catheter group. Favorable functional outcome was observed in 48% of patients treated with ACE68 reperfusion catheter and in 30% of patients treated using other Penumbra systems (p=0.120). Baseline Alberta Stroke Program Early CT Scores ${\geq}8$ (odds ratio [OR], 9.74; 95% confidence interval [CI], 1.72-54.99; p=0.010) and successful recanalization (OR, 10.20; 95% CI, 1.13-92.46; p=0.039) were independent predictors of favorable outcome. Conclusion : EVT using ACE68 reperfusion catheter can be considered a first-line therapy in patients with acute ICA occlusion as it can achieve rapid recanalization and reduce the frequency of conversion to stent-retrieve therapy.