• 제목/요약/키워드: Cast model

검색결과 383건 처리시간 0.05초

탄화분변토를 이용한 Benzene의 흡착특성 (Adsorption Characteristics of Benzene by Carbonized Cast)

  • 김재홍;손희정;김미룡
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.97-102
    • /
    • 1999
  • This study was carried out view that reuse of sludge of adsorbent for benzene in carbonized cast compare with activated carbon. Not only the carbonized cast is good than carbonized carbon in cation exchange capacity and 12 adsorption capacity, but also benzene adsorption capacity is no differences compare to activated carbon. As results, benzene adsorption capacity of carbonized cast and activated carbon are decreased as temperature increase($25~70^{\circ}C$).It is compatible in Lamgmuir model. Therefore, carbonized cast is applied general adsorbent. From experimental results and data regression, in model concerning effect of temperature, relative errors between the experimental data and those calculated by the model are within the range of 1.2~7.8%. In relative humidity effect (RH 0.25~0.50) of benzene adsorption, modified Freundlich model : $QB_{enzene}{;\}QB_{enzene},{\}_{RH=0}=1-kRH^{IN}$, relative errors between the experimental data and those calculated by the model are within are range of 0.5-5.1%. The constants k and l/n in equation were found to be 1.25, 1.89 in carbonized cast.

  • PDF

유도전동기 회전자 금형주조 시 품질평가 II (Quality Evaluations of Induction Motor Rotors during Die Casting Process II)

  • 박상철
    • 한국산학기술학회논문지
    • /
    • 제20권7호
    • /
    • pp.347-352
    • /
    • 2019
  • 본 연구는 소형 유도전동기 회전자를 생산공장에서 금형주조(die casting)로 제작 시 발생하는 cast 부 품질문제를 개선하기 위하여 수행되었다. 1차 연구결과와 현장 적용성을 고려한 수많은 parametric study를 통하여 새로운 rotor core cast model을 제안하였으며, 그 제안된 model에 대한 유효성을 평가, 검증하기 위하여 주조해석 전용프로그램을 사용한 수치해석과 실제품에 대한 현장실험을 통하여 다음과 같은 결론을 얻었다. 첫째, 유도전동기 회전자의 새로운 cast model에 대한 충진해석을 수행한 결과 용탕은 하부 end ring 부를 먼저 충진하고 이동하여 상부 end ring, core slot 부분을 충진하고 최종적으로 core slot 부분에서 충진이 완료된다. 둘째, 새롭게 제안된 rotor core cast model에 대한 용탕의 유동 양상을 보면 하부 end ring 부에 용탕의 유동에 의한 와류가 적게 발생하였으며, 현장실험 결과 하부 end ring 부 단면에서 소량의 작은 결함만이 발견되었다. 셋째, 유도전동기 회전자 제작 시 rotor core cast 형상 변경을 통하여 end ring 부 결함 발생 면적이 약 70 % 감소한 양호한 품질의 회전자를 생산할 수 있다.

구순열비 석고모형에서 간접인체계측법: 직접인체계측법과의 비교 (Indirect Anthropometry on Cast Model of Cleft Lip Nose: Comparison with Direct Anthropometry)

  • 한기환;정회준;진현석;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.18-23
    • /
    • 2007
  • Purpose: Anthropometry can be divided into two methods, direct anthropometry and indirect anthropometry. The most ideal and accurate method is a direct anthropometry. However, it is difficult to measure in the case of children because of poor cooperation, and it lacks re-productivity. Cast model has advantages of three dimensional featuring, inexpensive and easy fabrication. This study is conducted to find out an accuracy of indirect anthropometry on cast model by comparing it with direct anthropometry. Methods: Total 48 cleft lip nasal deformity patients (unilateral, 40; bilateral, 8) were included in this study. Cast models were made before surgery under general anesthesia with alginate impression material and model plaster. Eleven linear measurements among 7 landmarks were taken as direct anthropometry before surgery with Castroviejo spreading caliper. At the same time, indirect anthropometry on cast model was done at the same linear distances as well. Results: Of the total 11 linear measurements, both ala lengths, both columella lengths, nose width, projective distance between facial insertion points of the ala, projective distance between the alar base points, right nostril floor width, and columella width were statistically correlated between indirect anthropometry on cast model and direct anthropometry. However, the nasal tip protrusion and the left nostril floor width were not statistically correlated. Conclusion: Accuracy of indirect anthropometry on cast model can be influenced by cast model fabrication techniques and correct identification of landmarks. Nasal tip protrusion could be reduced by compression of the nasal tip in the process of cast model fabrication and nostril floor width can be varied by muscle relaxation of anesthetics and incorrect identification of subalare in cleft lip nasal deformity. If sufficient care is taken to make cast model and to define landmarks exactly, indirect anthropometry on cast model can be a reliable method as direct anthropometry.

수치해석에 의한 직매형 앵커기초의 인장 설계기준 평가 (Tensile Design Criteria Evaluation of Cast-In-Place Anchor by Numerical Analysis)

  • 장정범;서용표;이종림
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 2004
  • Numerical analysis is carried out to identify the appropriateness of the design codes that is available for the tensile design of fastening system at Nuclear Power Plant (NPP) in this study. This study is intended for the cast-in-place anchor that is widely used for the fastening of equipment in Korean NPPs. The microplane model and the elastic-perfectly plastic model are employed for the quasi-brittle material like concrete and for the ductile material like anchor bolt as constitutive model for numerical analysis and smeared crack model is employed for the crack and damage phenomena. The developed numerical model is verified on a basis of the various test data of cast-in-place anchor. The appropriateness of both ACI 349 Code and CCD approach of CEB-FIP Code is evaluated for the tensile design of cast-in-place anchor and it is proved that both design codes give a conservative results compared with real tensile capacity of cast-in-place anchor.

  • PDF

쾌속조형과 진공주형 및 세라믹 몰드를 이용한 금속 주조 시제품 제작 공정에서의 형상정밀도 변화 (Variations of Form Accuracy in the Process of Metal Cast Prototyping using Rapid prototype, Vacuum casting and Ceramic Mold)

  • 김기대
    • 한국정밀공학회지
    • /
    • 제24권6호
    • /
    • pp.131-137
    • /
    • 2007
  • In metal casting process, it is very difficult to predict the form accuracy of cast part and reduce repeatability error. In this study, the variations of form accuracy were measured in the process of metal cast prototyping, where RP part is manufactured from CAD model in the first, and then, wax part is cast in the vacuum environment using the RP part as master model, and finally metal prototype is cast using ceramic mold and the wax part as pattern. To investigate the variations of form accuracy, the averages and standard deviations of error distribution of the parts measured by 3D scanner were compared. It was observed that the biggest shrinkage is generated during the extraction of wax part in the second step and the biggest deterioration of form accuracy is generated during the metal part casting in the last step.

대형잉곳 전산모사 결함 정량화 및 활용연구 (Cast Defect Quantify on the Simulation for Large Steel Ingots and Its Application)

  • 남궁정;김용찬;김문철;윤중묵;채영욱;이동희;오상훈;김남수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.94-97
    • /
    • 2009
  • Cast defect in large steel ingots are estimated in quality and compared each other cast conditions on simulation results by now. The cast defects, micro-crack, shrinkage, pin hole which are predictable in simulation with a reasonable accuracy. In this study, 15 ton steel ingot casting was simulated for solidification model and cast defect prediction. And the real cast was carried out in a foundry for the compeer to the simulation results, the cast defect prediction. Also, the quantity of predicted defect was tried to measuring with the defect mach counting for the various simulated cast conditions. The defect quantity work was used to find the optimized cast condition in DOE(design of experiment) procedure.

  • PDF

악교정수술 환자에서 교합기 석고 모형과 측면두부방사선사진의 교합평면에 관한 비교 연구 (THE COMPARATIVE STUDY FOR OCCLUSAL PLANE BETWEEN ARTICULATED CAST MODEL AND CEPHALOGRAM IN ORTHOGANTIHIC SURGERY PATIENTS)

  • 서경숙;박미화;이주현;김철환;채종문
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권4호
    • /
    • pp.239-244
    • /
    • 2003
  • The common errors in preoperative treatment plan for the orthognathic surgery can be occurred during cast impression, cast mounting procedure with face-bow transfer, surgical stent fabrication, and so on. One of the most common errors exists during mounting process of the model on the articulator. Accurate mounting of dental casts to articulator should be achieved by transferring the 3-dimensional spatial relationship of the maxillary arch to an articulator. A face-bow is used for transfer this relationship to articulator, usually by relating the face-bow to a plane of reference of maxillary cast. The purpose of this study is evaluation of the accuracy of face-bow transferring of maxillary model to the articulator. The maxillary casts of thirty patients for orthognathic surgery were mounted on articulator with an face-bow instrument. The relationship of occlusal plane angle to Frankfort horizontal plane relations were compared the cephalogram with the cast-mounted articulator. As a result of this study, the significant difference between the maxillary occlusal planes angle in the cephalogram and articulator were found. The results were followed, 1. The mean occlusal plane angle in cast-mounted articulator was $13.5^{\circ}\;(SD{\pm}5.4)$. 2. The mean occlusal plane angle in cephalogram was $10.4^{\circ}\;(SD{\pm}4.3)$. 3. The mean difference of occlusal plane angle between cast-mounted articulator and cephalogram was $3.3^{\circ}\;(SD{\pm}4.6)$. According to the result, we should suggest that the occlusal plane angle to Frankfort plane in cast-mounted articulator is more steeper than that of cephalogram. And then, maxillofacial surgeon should try to get a more predictable result by suggesting the proper correction method and mounting the cast accurately.

사진 주사(走査)를 이용한 치과용 모형재의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF DENTAL CAST AND DIE MATERIALS USING PHOTO-SCANNING)

  • 양성욱;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.320-334
    • /
    • 1996
  • Dental cast and die materials are essential material using in almost dental prsthodontic procedure and it's most important requirement is accuracy for reqorducing the oral anatomical structures. In this study, 5 abutments A, B, C, D, E were fabricated on the metal master model to simulate the arch form and specimens were poured with 4 cast materials. Inter-abutment distances, A-B, A-C, A-D, A-E, B-C, B-D were calculated using the photo-scanning and the deviations from the metal master model were also evaluated. The results were as follows; 1. The distance between A-B, A-C, A-D, A-E, B-C, B-D of the abutments A, B, C, D, E of each cast material was calculated. And after comparing the deviations between the metal master model. $Fujirock^{(R)}$ showed the lowest value with $0.20{\pm}0.22mm$, and the deviation increased in the order of $Suprastone^{(R)}$, Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. 2. In each calculation area, the difference in measurements between cast material and metal master model showed singificant difference between A-B and Cross arch measure-ments of A-D, B-D, A-E(p<0.05). 3. The difference in measurements between cast material and metal master model in the A-B area showed $Fujirock^{(R)}$ to be the lowest with $0.05{\pm}0.04$mm and increased in the order of Die $Keen^{(R)}$, $Suprastone^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and $Suprastone^{(R)}$, Epoxy $Die^{(R)}$ (p<0.05). 4. The difference in measurements between cast material and metal master model in the B-C area showed $Fujirock^{(R)}$ to bo the lowest with $0.17{\pm}0.11$mm and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Die $Keen^{(R)}$, Epoxy $Die^{(R)}$(p<0.05). 5. The difference in measurements between cast material and metal master model in the B-D area showed $Fujirock^{(R)}$ to bo the lowest with $0.13{\pm}0.07$mm, Epoxy $Dies^{(R)}$and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fuji-rock^{(R)}$ and Die Keen(p<0.05). 6. In this experiment, Epoxy $Dies^{(R)}$ showed mean contraction in every calculation area. And when reconstruction cross arch restorations it is thought that distortion should be considered in every cast material.

  • PDF

신경망을 이용한 차량 객체의 그림자 제거 (Cast-Shadow Elimination of Vehicle Objects Using Backpropagation Neural Network)

  • 정성환;이준환
    • 한국ITS학회 논문지
    • /
    • 제7권1호
    • /
    • pp.32-41
    • /
    • 2008
  • 비디오를 이용한 비전기반 감시에서 움직이는 객체의 추적은 GMM (Gaussian Mixture Model)을 사용한 배경영상과 현재영상의 차이법을 이용한다. 문턱치를 통해 생성된 이진영상을 이용하여 객체 추적을 할 경우 객체 정보가 아닌 그림자에 의하여 객체가 병합되는 현상이 나타난다. 본 논문에서는 신경망(Backpropagation Neural Network)을 이용하여 그림자를 제거하는 방법을 제안하였다. 10개의 동영상에서 객체영역과 캐스트그림자(Cast-Shadow)영역의 훈련용 이미지에서 특징 값을 추출하여 신경망을 훈련시켰다. 캐스트그림자를 제거하는 방법은 이진영상의 객체로 추정되는 영역에서 그림자를 분리하는 방법을 기초로 하며 기존의 그림자 제거 알고리즘 (SNP, SP, DNM1, DNM2, CNCC)보다 그림자 제거 성능이 (16.2%, 38.2%, 28.1%, 22.3%, 44.4%)로 높게 나타났다.

  • PDF