• Title/Summary/Keyword: Cascade with broadening

Search Result 3, Processing Time 0.025 seconds

A method for purifying reprocessed uranium from even isotopes under conditions of multiple recycle

  • Smirnov, A.Yu.;Palkin, V.A.;Chistov, A.V.;Sulaberidze, G.A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3650-3659
    • /
    • 2022
  • We proposed a modification of a double cascade scheme to enrich reprocessed uranium. Such a cascade scheme represents a combination of one cascade with "broadening" of the flow and an ordinary three-flow cascade. A calculation and optimization method has been developed for the proposed scheme according to various efficiency criteria. It is shown that the proposed scheme makes it possible to obtain low-enriched uranium of commercial quality using reprocessed uranium of different initial compositions. For example, the enrichment of reprocessed uranium, which had gone through five consequent recycles, was considered. The proposed scheme allowed to enrich it with simultaneous fulfillment of restrictions on isotopes 232U, 234U, and 236U. Such results indicate the scheme's applicability under conditions of multiple recycling of uranium in reactor fuel. Computational experiments have shown that in the proposed modification, a noticeable saving of natural uranium in the cycle (~18%) can be achieved, provided that the additional consumption of separative work does not exceed 10%, compared with the case of enrichment of natural uranium to obtain LEU of equivalent quality.

A Pseudo-Random Carrier PWM Technique by Fixed Frequency Carrier Composition (고정 주파수의 캐리어 합성에 의한 준 랜덤 주파수 캐리어 PWM기법)

  • Kim, Jong-Nam;Jung, Young-Gook;Lim, Young-Cheol;Park, Sung-.Jun;Kim, Kwang-Heon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.547-552
    • /
    • 2005
  • This paper describes a pseudo-random carrier PW technique for the power converters. The proposed method generates a new pseudo-random carrier by randomly composing a carrier with fixed frequency and a carrier with opposition phase. To confirm the validity of the proposed method, a single-phase multi-level inverter was implemented and tested. The experimental results show that the output voltage and current harmonics spectra of an inverter have broadening effect of harmonics, as only simple composition of fixed frequency carries.

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.