• 제목/요약/키워드: Cascade refrigeration

검색결과 56건 처리시간 0.021초

이산화탄소를 이용한 냉동·냉장 시스템의 성능연구 (Performance of Carbon Dioxide System for Freezing and Refrigeration)

  • 김윤섭;윤린
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.81-86
    • /
    • 2015
  • Performance of freezing and refrigeration systems in supermarket, which utilized $CO_2$ as a refrigerant, was investigated by using the Pack Calculation II. The configuration of simulated systems was basic parallel refrigeration system, cascade system, and two-stage system. The $CO_2$ cascade system showed higher COP than basic parallel R404A system by 13% for MT and 62% for LT, respectively. Among the $CO_2$ cascade systems, R717(MT)-$CO_2$(LT) showed the highest performance. Open-type intercooler method showed higher performance than liquid injection for the two-stage $CO_2$ systems.

캐스케이드 냉동시스템과 2단 압축 1단 팽창식 냉동 시스템의 성능 비교 (Performance comparison of cascade refrigerator and two-stage compression refrigerator)

  • 손창효
    • 한국산학기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.625-631
    • /
    • 2014
  • $-30^{\circ}C{\sim}-50^{\circ}C$ 범위의 저온 증발온도를 얻기 위해서는 2단 압축 1단 팽창식 냉동 시스템이나 캐스케이드 냉동 시스템이 필요하다. 하지만 이러한 냉동시스템의 성능 비교에 대한 연구 결과는 대단히 부족한 실정이다. 본 논문은 R744-R404A용 캐스케이드 냉동시스템과 R404A용 2단 압축 1단 팽창식 냉동 시스템의 성능을 서로 비교한 것이다. $-30^{\circ}C{\sim}-50^{\circ}C$의 증발온도 범위에서 2단 압축 1단 팽창식 냉동시스템의 성능계수가 캐스케이드 냉동시스템 보다 약 36%~57% 정도 높다. 하지만, 2단 압축 1단 팽창식 냉동 시스템의 경우 증발온도와 압축효율 감소시에 성능계수의 변화가 커서 안정적이지 못하다. 특히, 압축효율 감소시에 성능계수가 크게 감소하는데, 이는 장기간 냉동 시스템의 사용시에 단점이 될 수 있다. 반면, R744-R404A용 캐스케이드 냉동 시스템은 자연냉매를 사용하여 친환경적이며, 고온과 저온 사이클에 사용되는 냉매의 적절한 선택에 의해서 다양한 온도영역에서 고효율 냉동 시스템을 구성할 수 있다. 위의 결과로부터, 성능과 환경적인 측면을 고려하여 용도에 따라 적합한 저온 냉동시스템을 선택하는 것이 좋으리라 판단된다.

R744-R404A 캐스케이드 냉동시스템의 최적 냉매 충전을 위한 질량유량비 분석 (Mass flow rate ratio analysis for optimal refrigerant charge of a R744 and R404A cascade refrigeration system)

  • 오후규;손창효;조환;전민주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.575-581
    • /
    • 2013
  • 본 논문은 R744-R404A 캐스케이드 냉동시스템의 최적 냉매 충전을 위해 과냉도, 과열도, 내부열교환기 효율 등에 대한 영향을 분석한 것이다. 연구에 사용된 캐스케이드 냉동시스템의 고온 사이클에는 R404A, 저온 사이클에는 R744를 적용하였다. 그 주요 결과는 다음과 같다 : 고온 사이클의 과냉도, 과열도, 내부열교환기 효율과 저온 사이클의 증발온도와 압축효율은 크게 할수록 질량유량비가 작게 나타났다. 그리고 캐스케이드 온도차와 고온 사이클의 증발온도, 응축온도와 저온 사이클의 과냉도, 과열도, 내부열교환기 효율은 작을수록 질량유량비가 작게 나타났음을 확인하였다.

R744-R404A용 캐스케이드 냉동시스템의 엑서지 분석 (Exergy Analysis of R744-R404A Cascade Refrigeration System)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1001-1008
    • /
    • 2011
  • 본 논문은 내부 열교환기를 가지는 R744와 R404A용 캐스케이드 냉동시스템의 운전변수에 대한 최적의 설계를 위해서 냉동장치의 성능과 엑서지를 이론적으로 분석하였다. 본 연구에서 고려된 작동변수로는 과열도와 과냉각도, 내부 열교환기와 압축기 효율, 증발 및 응축온도 등이다. 분석한 결과를 요약하면 다음과 같다. 캐스케이드 증발온도가 증가할수록 R404A용 고온사이클의 COP는 증가하는 반면에, R744용 저온사이클의 COP는 감소한다. 따라서 이러한 이유로 전체 캐스케이드 냉동사이클의 COP는 거의 일정하다. 또한 캐스케이드 증발온도가 증가할수록 R404A용 응축기와 압축기의 엑서지 손실이 가장 큰 것을 알 수 있다. 따라서 R744와 R404A용 캐스케이드 냉동시스템의 COP 향상을 위해서는 R404용 응축기와 압축이의 엑서지 손실을 줄여야만 한다.

고온측 냉매에 따른 이원 냉동시스템의 성능 분석 (Performance Analysis of Cascade Refrigeration System with Respect to Refrigerants Appling to High Temperature Cycle)

  • 윤정인;전민주;손창효
    • 동력기계공학회지
    • /
    • 제21권3호
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents the Coefficient of performance(COP) and mass flow ratio of cascade refrigeration system with respect to refrigerants appling to high temperature cycle. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporating temperature, condensing temperature and internal heat exchanger effectiveness in high temperature cycle. The result of this study is as follows : The COP of cascade system increases with increasing degree of superheating and subcooling, compressor efficiency and internal heat exchanger effectiveness except increasing condensing temperature. The mass flow ratio of low and high temperature cycle increases with increasing evaporating temperature and condensing temperature, but decreases with increasing internal heat exchanger effectiveness, degree of superheating and subcooling. Also, the mass flow ratio has no correlation with compressor efficiency at high temperature cycle.

참치 어선 냉동장치의 개발에 관한 연구 (Development of Refrigeration Equipment for Tuna Long Liner)

  • 오후규;정재천;김성규;구학근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제16권4호
    • /
    • pp.78-87
    • /
    • 1992
  • The experimental study and theoretical analysis are made in order to investigate a new refrigeration system, R-22 and R-502 or R-13 cascade compressor with panel type cooler, for tuna long liner. The experimental apparatus consists with the cascade unit, 1.5 HP R-502 compressor in the first stage and 1 HP R-22 compressor in the second stage, and 3 $m^2$ cold storage room with a direct expansion panel type cooler. The main result are as follows: 1. The energy saving and C.O.P. of the R-22 and R-502 or R-22 and R-13 cascade are improved much higher than two stage compressor. 2. For the point of simplicity of design, installation, and running cost, the panel type cooler is much better than traditional hair pin coil type cooler. 3. From the experimental data and analysis, the R-22 and R-502, or R-22 and R-13 cascade compressor with panel type cooler is recommended for a new refrigeration equipment of the tuna long liner.

  • PDF

R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 - (Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) -)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.189-195
    • /
    • 2011
  • 본 논문은 R744-R404A용 캐스케이드 냉동시스템의 기초 설계자료를 제공하기 위해서 COP 예측 상관식을 제안하고 그 결과를 타 상관식과 비교하였다. 작동변수로는 R404A용 고온사이클과 R744용 저온사이클의 과냉각도와 과열도, 압축기효율, 응축과 증발온도이다. 이에 대한 주요결과를 요약하면 다음과 같다. 다중회귀 분석을 통해 R744-R404A용 캐스케이드 냉동시스템의 성능 예측식을 제안하였고, 그 결과를 타 연구자들의 상관식과 비교하였다. 그 결과 본 연구에서 제안한 성능 예측식은 타 연구자들의 상관식과 일치하지 않았다. 따라서 향후 R744-R404A용 캐스케이드 냉동시스템에 대한 추가 실험 데이터와 본 연구에서 제안한 COP 예측 상관식을 비교하여 그 신뢰성을 확보할 필요가 있다.

천연가스 액화를 위한 캐스케이드 냉동사이클의 전산모사에 대한 연구 [2]: 다단 캐스케이드 냉동 사이클에 적용 (A Simulation Study on the Cascade Refrigeration Cycle for the Liquefaction of the Natural Gas [2]: An Application to the Multistage Cascade Refrigeration Cycle)

  • 조정호;김유미
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.1013-1019
    • /
    • 2011
  • 본 논문에서는 천연가스를 액화시키기 위해서 프로판, 에틸렌 및 메탄 냉매를 이용한 다단 캐스케이드 냉동사이클에 대한 전산모사를 PRO/II with PROVISION 8.3에 내장되어 있는 Peng-Robinson 상태방정식을 활용하여 수행하였다. 천연가스의 조성은 한국가스공사로부터 제공받은 것을 적용하였으며, 유량은 연간 500만톤으로 가정하였다. 프로판 냉매의 공급온도는 $-40^{\circ}C$로, 에틸렌 냉매의 공급온도는 $-95^{\circ}C$로 메탄 냉매의 공급온도는 $-155^{\circ}C$로 각각 정하였으며, 천연가스와 각각의 냉매의 최소 접근온도는 $3^{\circ}C$로 정하였다. 다단 냉동을 위한 프로판 냉동 사이클은 3단 냉동을 가정하였으며, 에틸렌 냉동 사이클은 2단 냉동을 그리고 메탄 냉동 사이클은 3단 냉동을 가정하였다. 메탄 냉매에 의해서 $-152^{\circ}C$까지 냉각된 천연가스는 줄-톰슨 팽창에 의해서 $-162^{\circ}C$까지 냉각되어 액화가 일어나도록 하였다. 결론적으로 캐스케이드 냉동 사이클과 줄-톰슨 팽창을 통한 천연가스의 액화율은 몰 비로 91.71%이며, 액화천연가스 1.0 kg/hr당 0.433 kW의 압축 일이 필요함을 알 수 있었다.

메탄, 에틸렌 및 프로판 냉매를 활용한 다원 냉동 사이클에서 LNG 냉열을 활용한 동력 절감 방안에 대한 연구 (A Study on the Power Saving with the Use of LNG Cold Heat in a Cascade Refrigeration Cycle using Methane, Ethylene and Propylene as Refrigerants)

  • 조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제31권3호
    • /
    • pp.302-306
    • /
    • 2020
  • In this study, computer simulation works using PRO/II with PROVISION V10.2 have been performed for a cascade refrigeration cycle using methane, ethylene and propane as refrigerants. LNG cold heat was also utilized in order to save the compression powers for the ethylene and propane refrigeration cycles. It was concluded that about 77% of compression power can be saved by using LNG cold heat through the exchanging heat with refrigerants. We could also know that the cold heat price contained in 1 ton of LNG is 16,155 won.