• Title/Summary/Keyword: Cartridge

Search Result 494, Processing Time 0.023 seconds

Effect of potato starch on suitability for 3D printing in golden threadfin bream (Nemipterus virgatus) surimi mixture preparation (감자 전분의 첨가가 수리미 혼합물 제조에서 3D 프린팅 적합성에 미치는 영향)

  • Seo, Hun-Seo;Park, Ye-Lin;Park, Jeong-Cheol;Han, Hyeon-Su;Kang, Yoo-Seok;Choi, Ye-Hui;Kim, Su-Hyeong;Kim, Han-Ho;Jeong, So-Mi;Kang, Woo-Sin;Kim, Su-Ryong;Ryu, Si-Hyeong;Lee, Ji-Eun;Xu, Xiaotong;Lee, Ga-Hye;Ahn, Dong-Hyun
    • Journal of Applied Biological Chemistry
    • /
    • v.64 no.4
    • /
    • pp.413-419
    • /
    • 2021
  • In this study, we investigated the physical properties, color values of mixtures with starch from potato in preparing a cartridge for 3D printing using golden threadfin bream (Nemipterus virgatus) surimi as raw material. The results show that the hardness and gumminess of the surimi mixture added potato starch increased but cohesiveness decreased compared to the negative control. This means that the starch makes surimi stronger texture than the negative control. After 7 days of cold storage at 4 ℃, for unheated surimi, firmness is increased but adhesiveness is decreased. And among physical properties of surimi stored after heating, hardness and gumminess were decreased compared to before storage. Lastly, after storage for 7 days, the hardness and gumminess of fried surimi decreased compared to fried surimi before storage. As a result of sensory evaluation, texture, elasticity scent of surimi stored after heating were decreased but overall favorability was similar. Compared to the after storage, result of sensory evaluation of fried surimi, result of the before storage showed no significant differences. From these results, it is suggested that potato starch, which increases overall physical strength and have little effect on preference, can be used as an additive for golden threadfin bream surimi.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.

Studies on the Determination Method of Natural Sweeteners in Foods - Licorice Extract and Erythritol (식품 중 감초추출물 및 에리스리톨 분석법에 관한 연구)

  • Hong Ki-Hyoung;Lee Tal-Soo;Jang Yaung-Mi;Park Sung-Kwan;Park Sung-Kug;Kwon Yong-Kwan;Jang Sun-Yaung;Han Ynun-Jeong;Won Hye-Jin;Hwang Hye-Shin;Kim Byung-Sub;Kim Eun-Jung;Kim Myung-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.258-266
    • /
    • 2005
  • Licorice Extract and Erythritol, food additives used in korea, are widely used in foods as sweetener. Its application for use in food is regulated by the standard and specification for food additives but official analytical method far determination of these sweetener in food has not been established. Accordingly, we has been carried out to set up analytical method of the glycyrrhizic acid in several foods by the way of thin layer chromatography and high performance liquid chromatography glycyrrhizic acid is qualitative anaylsis technique consists of clean-up with a sep-pak $C_{18}$ cartridge, separation of the sweeteners by Silica gel 60 F254 TLC plate using 1-butanol:4Nammonia solution:ethanol (50:20:10) as mobile solvent. Also, the quantitative analysis for glycyrrhizic acid, was performed using Capcell prk $C_{18}$ column at wavelength 254nm and DW:Acetonitrile (62:38 (pH2.5)) as mobile phase. and we has been carried out to set up analytical method of the erythritol in several foods by the way of high performance liquid chromatography. erythritol is qualitative anaylsis technique consists of clean-up with a DW and hexane. The quantitative analysis for erythritol, was performed using Asahipak NH2P-50 column, Rl and DW:Acetonitrile (25:75) as mobile phase. The glycyrrhizic acid results determined as glycyrrhizic acid in 105 items were as follows; N.D$\∼$48.7ppm for 18 items in soy sauce, N.D$\∼$5.3ppm for 12 items in sauce, N.D$\∼$988.93ppm for 15 items in health food, N.D$\∼$180.7ppm for 26 items in beverages, N.D$\∼$2.6ppm for 8 items in alcoholic beverages repectively and ND for 63 items in the ethers. The erythritol results determined as erythritol in 52 items were as follows; N.D$\∼$155.6ppm for 13 items in gm, N.D$\∼$398.1ppm for 12 items in health foods repectively and ND for 45 items in the others.