• 제목/요약/키워드: Carpal Muscle

검색결과 27건 처리시간 0.023초

방아쇠수지가 손목터널증후군 환자의 악력, 통증 및 상지기능에 미치는 영향: 단면적 연구 (Effect of Trigger Finger on Pain, Grip Strength and Function of Upper Limb of Patients with Carpal Tunnel Syndrome: A Cross-sectional Study)

  • 김명권;윤다은
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.63-71
    • /
    • 2021
  • PURPOSE: The purpose of this study was to investigate the effects of trigger finger on pain, muscle strength and function in carpal tunnel syndrome (CTS) patients. METHODS: A total of 60 subjects (30 carpal tunnel syndrome with trigger finger and 30 carpal tunnel syndrome without trigger finger) were assessment for pain, muscle strength (power grip, key pinch , tip to tip pinch, three jaw pinch) and function. The effect sizes of the two groups were compared, and the correlation between the trigger finger and each variable was analyzed. RESULTS: The results showed that there were significantly difference in the pain, muscle strength excluding three jaw pinch and function (p < .05). The results also showed correlation between trigger finger and pain (r = .552), muscle strength excluding three jaw pinch (power grip r = -.296, key pinch r = -.260, tip to tip pinch r = -.285), and function (r = .375). The function of carpal tunnel syndrome patients was related to pain (r = .550) and power grips (r = -.324) of muscle strength. CONCLUSION: In carpal tunnel syndrome patients with trigger finger compared to carpal tunnel syndrome, muscle weakness, pain increase, and function reduction were shown. In addition, trigger finger are correlated with muscle strength, pain and function, and muscle weakness and increased pain affect the daily living of carpal tunnel syndrome patients with triggers finger. Therefore, physical therapy interventions of carpal tunnel syndrome patients with trigger finger should be combined with treatment for muscle strength enhancement as well as pain reduction.

Recurrent carpal tunnel syndrome associated with extension of flexor digitorum muscle bellies into the carpal tunnel: A case series

  • Castillo, Rochelle;Sheth, Khushboo;Babigian, Alan;Scola, Christopher
    • Archives of Plastic Surgery
    • /
    • 제45권5호
    • /
    • pp.474-478
    • /
    • 2018
  • While the success or failure of carpal tunnel release ultimately depends on the interplay of a wide array of factors, a broad understanding of the normal anatomy of the carpal tunnel accompanied by awareness of the possible variations of the individual structures that make up its contents is crucial to optimizing surgical outcomes. While anatomic variants such as extension of the flexor digitorum muscle bellies have been described as a cause of primary carpal tunnel syndrome (CTS), there have been no reports depicting its association with recurrent CTS following initially successful carpal tunnel release, a finding with potentially significant prognostic implications that can aid in operative planning. In such cases where muscle extension is identified preoperatively, careful debulking of the muscle belly may be beneficial in improving long-term surgical outcomes.

인체 수관절 근육의 진동 응답 (Vibration Response of a Human Carpal Muscle)

  • 전한용;김진오;박광훈
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.31-40
    • /
    • 2011
  • This paper examines the dynamic characteristics of a human carpal muscle through theoretical analysis and experiment. The carpal muscle was modeled as a 1-DOF vibration system and vibration response due to a ramp function force was calculated. The electromyogram signal corresponding to the muscle excitation force was measured, and the excitation force function of an envelope curve from the electromyogram signal was extracted. The ramp input function of electrical stimulation to the carpal muscle was applied by using a device for functional electrical stimulation, and the angular displacements corresponding to steady state response were measured. Theoretical calculations of the vibration response displacements were compared with the experimental results of the angular displacements, and have shown a good agreement with the result that is linearly proportional to the excitation force magnitude. As a result, the relationship between the input current of the electrical stimulation and the excitation force magnitude was inferred. The result was shown that it can be applied to develop rehabilitation training devices.

Anomalous Muscles of the Wrist Encountered During Endoscopic Carpal Tunnel Surgery

  • Park, Se-Hyuck
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권1호
    • /
    • pp.90-95
    • /
    • 2019
  • Objective : Anomalous muscles of the wrist are infrequently encountered during carpal tunnel surgery. Anatomic variants of the palmaris longus (PL), flexor digitorum superficialis, lumbricalis and abductor digiti minimi (ADM) have been reported but are usually clinically insignificant. Anomalies of the wrist muscles, encountered during endoscopic carpal tunnel surgery have rarely been described. I conducted this study to evaluate muscular anomalies of the volar aspect of the wrist, encountered during endoscopic carpal tunnel surgery. Methods : I studied a consecutive series of 1235 hands in 809 patients with carpal tunnel syndrome who underwent single-portal endoscopic carpal tunnel release (ECTR) from 2002 to 2014. Nine hundred seventy-three hands in 644 patients who had minimal 6-month postoperative follow-up were included in the study. The postoperative surgical outcome was assessed at least 6 months after surgery. Results : In eight patients, anomalous muscles were found under the antebrachial fascia at the proximal wrist crease and superficial to the ulnar bursa, passing superficial to the transverse carpal ligament. Those anomalous muscles were presumed to be variants of the PL or accessory ADM muscle, necessitating splitting and retraction to enter the carpal tunnel during the ECTR procedure. Other muscle anomalies were not seen within the carpal tunnel on the endoscopic view. The surgical outcome for all eight wrists was successful at the 6-month postoperative follow-up. Conclusion : Carpal tunnel surgeons, especially those using an endoscope should be familiar with unusual findings of anomalous muscles of the wrist because early recognition of those muscles can contribute to avoiding unnecessary surgical exploration and unsuccessful surgical outcomes.

Anatomical Study on the Heart Meridian Muscle in Human

  • Park Kyoung-Sik
    • 대한한의학회지
    • /
    • 제26권1호
    • /
    • pp.11-17
    • /
    • 2005
  • This study was carried out to identify the components of the human heart meridian muscle, the regional muscle group being divided into outer, middle, and inner layers. The inner parts of the body surface were opened widely to demonstrate muscles, nerves, blood vessels and to expose the inner structure of the heart meridian muscle in the order of layers. We obtained the following results; $\cdot$ The heart meridian muscle is composed of muscles, nerves and blood vessels. $\cdot$ In human anatomy, the difference between terms is present (that is, between nerves or blood vessels which control the meridian muscle and those which pass near by). $\cdot$ The inner composition of the heart meridian muscle in the human arm is as follows: 1) Muscle H-l: latissimus dorsi muscle tendon, teres major muscle, coracobrachialis muscle H-2: biceps brachialis muscle, triceps brachialis muscle, brachialis muscle H-3: pronator teres muscle and brachialis muscle H-4: palmar carpal ligament and flexor ulnaris tendon H-5: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficialis tendon, flexor digitorum profundus tendon H-6: palmar carpal ligament & flexor retinaculum, flexor carpi ulnaris tendon H-7: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficial is tendon, flexor digitorum profundus tendon H-8: palmar aponeurosis, 4th lumbrical muscle, dorsal & palmar interrosseous muscle H-9: dorsal fascia, radiad of extensor digiti minimi tendon & extensor digitorum tendon 2) Blood vessel H-1: axillary artery, posterior circumflex humeral artery H-2: basilic vein, brachial artery H-3: basilic vein, inferior ulnar collateral artery, brachial artery H-4: ulnar artery H-5: ulnar artery H-6: ulnar artery H-7: ulnar artery H-8: palmar digital artery H-9: dorsal digital vein, the dorsal branch of palmar digital artery 3) Nerve H-1: medial antebrachial cutaneous nerve, median n., ulnar n., radial n., musculocutaneous n., axillary nerve H-2: median nerve, ulnar n., medial antebrachial cutaneous n., the branch of muscular cutaneous nerve H-3: median nerve, medial antebrachial cutaneous nerve H-4: medial antebrachial cutaneous nerve, ulnar nerve H-5: ulnar nerve H-6: ulnar nerve H-7: ulnar nerve H-8: superficial branch of ulnar nerve H-9: dorsal digital branch of ulnar nerve.

  • PDF

개에서 요골쪽앞발목굽힘근과 얕은앞발가락굽힘근을 이용한 앞발목 부위의 연부조직 결손 재건 증례 (Transposition of Flexor Carpi Radialis and Superficial Digital Flexor Muscles for Reconstruction of Carpal Injury in a Dog)

  • 소경민;김주호;이해범;허수영;고재진;이철호;전승기;김남수
    • 한국임상수의학회지
    • /
    • 제24권2호
    • /
    • pp.276-279
    • /
    • 2007
  • A 2-year-old male, 3 kg body weight Japanese Chin was injured in the automobile accident three months ago. The dog became antebrachiocarpal joint instability, and performed pancarpal arthrodesis using 3 K-wires in localanimal hospital. But, the result was failure. Therefore the dog was referred to Chonbuk Animal Medical Center, Chonbuk National University. In physical examination, right carpal joint instability, knuckling sign and pain were evident. In radiography, sclerosis was observed on the 4th carpal bone. Complete blood count (CBC), serum chemistry and urinalysis finding were within reference ranges. Pancarpal arthrodesis was re-performed using 7-hole plate. However, mild skin and muscle defects was appeared by skin tension of extremity. We expected that granulation would fill the defect, but inflammation was continued on the lesions for 3 days. So, operation which is filling it was done by using the muscle flap and tubed skin flap. The donor muscles were flexor carpi radialis and superficial digital flexor muscles. After 7 days, the muscle flap was survived, but tubed skin flap was necrosed. After 20 days, the skin defect was substituted with granulation tissues. The flexor carpi radialis muscle and superficial digital flexor muscle transposition can be a useful procedure for reconstructing soft tissue defects in the carpal and metacarpal areas.

인체 수관절 운동과 근전도의 상관관계 (Correlation of Human Carpal Motion and Electromyogram)

  • 전한용;김진오;박광훈
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1393-1401
    • /
    • 2010
  • 본 논문은 인체 수관절 운동과 표면 근전도의 상관관계를 실험적으로 다룬다. 수관절의 해부학적 구조를 분석하여, 수관절 운동 형상을 파악하고 운동을 발생시키는 주요 근육을 선정하였다. 수관절 재활 훈련 장치를 이용하여 수관절 운동에 저항하는 토크를 가하고, 이 때 주요 근육에서 토크에 따른 표면 근전도 신호를 측정하였다. 측정된 표면 근전도 신호의 크기를 계산하여 수관절 운동과의 연관성 분석에 사용하였다. 실험 결과로부터 수관절 토크와 표면 근전도 신호의 크기가 토크 $0.1\;N{\cdot}m$ 이하의 수관절 운동에서는 선형적으로 비례함을 밝혔고, 수관절 근육의 단면적에 따라 표면 근전도 신호의 크기도 선형적으로 비례함을 확인하였다. 또한 수관절 운동에 관여하는 각 근육의 기여도를 분석한 결과, 각 운동을 발생시키는 가장 주도적인 2개의 근육 중에서 한 근육의 기여도가 약 60 %로서 일관성 있게 나타났다. 이러한 세 가지 실험 결과로 좀 더 정교한 수관절 재활 훈련 장치나 로봇 등을 제작하는데 응용할 수 있다.

Median Nerve Injuries Caused by Carpal Tunnel Injections

  • Kim, Hyun Jung;Park, Sang Hyun
    • The Korean Journal of Pain
    • /
    • 제27권2호
    • /
    • pp.112-117
    • /
    • 2014
  • Local steroid injections are widely used for diagnostic and therapeutic purposes in the management of carpal tunnel syndrome. The median nerve injury is the most serious complication in association with carpal tunnel injections although the incidence is low. A median nerve injury will be presented with shooting pain at the injection time along with other sensory distortion, motor weakness and muscle atrophy. The management includes a conservative treatment and a surgical exploration. Carpal tunnel injections should be used at a minimum only. If such steroid injection is required, an appropriate needle positioning is vital for the nerve injury prevention. The patient should not be heavily sedated and should be encouraged to inform experiences of numbness/paresthesia during the procedure immediately.

수근관 증후군에 동반된 운동 반회 신경 가지의 포착: 증례보고 (Carpal Tunnel Syndrome with Recurrent Motor Branch Entrapment: A Case Report)

  • 권영우;최인철;권희규;박종웅
    • Archives of Hand and Microsurgery
    • /
    • 제23권4호
    • /
    • pp.267-270
    • /
    • 2018
  • 운동 반회 신경 가지의 포착 증후군은 정중신경 운동 반회 가지(recurrent motor branch of median nerve)의 해부학적 변이에서 발생하는 압박에 의한 신경병증(compressive neuropathy)이다. 빈도는 매우 드물지만 이러한 해부학적 변형이 원인이 된 경우 횡수근 인대 유리술(transcarpal ligament release)만을 시행한다면 무지구군의 위축과 위약은 잔존하게 될 가능성이 높다. 저자들은 젊은 요리사에서 칼자루에 무지구근 주위가 반복적으로 자극된 이후 발생한 수근관 증후군에 동반된 운동 반회 신경 가지의 포착 증후군을 진단하고 운동 반회 신경 분지의 감압술(decompreesion) 및 신경박리술(neurolysis)을 시행한 1예를 경험하여 문헌고찰과 함께 보고하고자 한다.

미세전류 손목 보호대 착용이 손목터널증후군 노인 여성의 통증 척도, 관절가동범위 및 근력에 미치는 영향 (Effects of Wearing a Microcurrent Wrist Guard on Pain Scale, Range of Motion, and Muscle Strength in Elderly Women with Carpal Tunnel Syndrome)

  • 박혜선;박진희;김주용
    • 패션비즈니스
    • /
    • 제27권5호
    • /
    • pp.1-12
    • /
    • 2023
  • The purpose of this study was to investigate impact of wearing low-level current wrist guards on pain scale, range of motion (ROM), and muscle strength in elderly women with Carpal Tunnel Syndrome (CTS). Subjects were 12 elderly women aged between 65 and 85 years who were diagnosed with CTS symptoms. Measurements included grip strength and wrist ROM. Wrist ROM was assessed through flexion and dorsiflexion. Wrist guards were worn. After two weeks, pain level was assessed using the Visual Analogue Scale (VAS). Results showed a significant reduction in VAS score in the MES group after stimulation, whereas there was no difference in the control group. However, there was no significant difference in ROM between the MES group and the control group. Grip strength increased in the MES group after two weeks (p ≤ 0.001). In conclusion, clinical trials suggest that MES wrist guards might be provided as an adjunctive treatment method for CTS patients. This study provides foundational data for the design and use of auxiliary devices such as gloves in the field of MES research for pain reduction, ROM improvement, and muscle strength enhancement resulting from CTS.