• 제목/요약/키워드: Care temperature

검색결과 368건 처리시간 0.032초

질 성형을 위한 실리콘 액 주입 후 발생한 급성 호흡 곤란 증후군 1예 (A Case of Acute Respiratory Distress Syndrome Induced by Injection of Silicone Fluid for Colpoplasty)

  • 정창욱;전익수;장재영;박지은;송춘영;김성헌;강경우
    • Tuberculosis and Respiratory Diseases
    • /
    • 제57권2호
    • /
    • pp.193-196
    • /
    • 2004
  • 저자들은 실리콘 액을 이용한 질 성형술 후에 급성호흡 곤란 증후군을 보인 환자에서 경기관지 폐생검으로 실리콘에 의한 것으로 생각되는 폐포 대식세포내의 봉입체를 확인하고 대증적인 치료로 호전된 1예를 경험하였기에 문헌고찰과 함께 보고하는 바이다.

중환자실 뇌혈관질환자에게 수행된 간호중재분석 (A study of the Nursing Interventions performed by the ICU nurses to the patients with Cerebrovascular disorders)

  • 박영례;최경숙
    • 재활간호학회지
    • /
    • 제4권1호
    • /
    • pp.94-104
    • /
    • 2001
  • The purpose of this study was to analysis of nursing interventions performed by the ICU nurses to the patients with cerebrovascular disorder practically from one university hospital in Seoul. The data were collected from 15 nurses with 86 cerebrovascular disorder cases from one ICU with the questionaire to write frequency of nursing care done by the surveyee from May, 2, 2000 to July, 3, 2000 and the list of 66 nursing interventions selected out of 433 NIC(Nursing Interventions Classification) of Iowa University which were translated into Korean (44 items) and core nursing interventions by ICU nurses (22 items; KIm, Su-Jin, 1997). The data were analysed with SPSS program. The results are as follow : 1. The most frequently used nursing interventions were vital sign monitoring, fall prevention, cerebral edema management, dysreflexia management, neurologic monitoring, cardiac care, communication enhancement, technology management, bed rest care, respiratory monitoring in rank. 2. The most frequently used nursing intervention domains were 'Physiological : Complex', 'Physiological : basic', 'Behavior', 'Safty', 'Health system' in rank. In the domain of physiological : basic, the most frequently used nursing interventions were bed rest care, urinary elimination management, tube care : urinary, physical restraints in rank. In the domain of physiological : complex, the most frequently used nursing interventions were cerebral edema management, dysreflexia management, neurologic monitoring, cardiac care in rank. In the domain of behavior, the most frequently used nursing interventions were communication enhancement, touch, active listening in rank. In the domain of safty, the most frequently used nursing interventions were vital sign monitoring, fall prevention in rank. In the domain of health system, the most frequently used nursing interventions were technology management, specimen management in rank. 3. some difference of the frequency practicing the nursing interventions according to the shift of duties was found. For example, medication administration was common at day duty, touch was practiced at evening duty, temperature regulation was performed.

  • PDF

치매요양시설에서의 치료를 위한 빛·색채의 시설적 적용 특성에 관한 고찰 - 정성적 및 정량적 적용 특성을 중심으로 (A Study on the Characteristics of Application for Therapeutic Light and Color in Dementia Care Facilities - Focused on Qualitative and Quantitative Application Characteristics)

  • 지수인
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권4호
    • /
    • pp.69-87
    • /
    • 2018
  • Purpose: This study has been started with the awareness that light and color are the main visual sensors of the multi-sensory stimulation environment to achieve the therapeutic environment for demented elderly. The purpose of this study therefore is for clarifying the application characteristics of therapeutic light and color for dementia care facilities. Methods: Internal and external literature reviews have been conducted for the investigation into a)disorders and visual system in demented elderly, b)therapeutic effects of light and color, c)heliotherapy, light therapy and color therapy to deduce the therapeutic characteristics of light and color for demented elderly, and finally into d)the application characteristics of it for dementia care facilities. Results: The application characteristics of the therapeutic light and color for dementia care facilities are classified into both qualitative and quantitative characteristics. Qualitative application characteristics of light represented using of daylight, using of lighting approximate to daylight, expansion of iluminance level, equality in iluminance Level, reduction of shadow, and as well as exclusion of blare. Quantitative application characteristics of it represented iluminance level, color temperature and color rendering index prescribed in international lighting standards. Qualitative application characteristics of color represented non-monochromatic color, color contrast, long wavelength of yellow-red colors, exclusion of short wavelength of blue colors and patterns, and as well as different colors for idenfication. Quantitative application characteristics of it represented kontrast(K) prescribed in DIN32975:2009 and light reflectance value(LRV) prescribed in BS8300:2009. Implications: To form dementia care facilities as therapeutic environment both qualitative and quantitative application characteristics of therapeutic light and color in dementia care facilities are needed.

Comparison between Gel Pad Cooling Device and Water Blanket during Target Temperature Management in Cardiac Arrest Patients

  • Jung, Yoon Sun;Kim, Kyung Su;Suh, Gil Joon;Cho, Jun-Hwi
    • Acute and Critical Care
    • /
    • 제33권4호
    • /
    • pp.246-251
    • /
    • 2018
  • Background: Target temperature management (TTM) improves neurological outcomes for comatose survivors of out-of-hospital cardiac arrest. We compared the efficacy and safety of a gel pad cooling device (GP) and a water blanket (WB) during TTM. Methods: We performed a retrospective analysis in a single hospital, wherein we measured the time to target temperature ($<34^{\circ}C$) after initiation of cooling to evaluate the effectiveness of the cooling method. The temperature farthest from $33^{\circ}C$ was selected every hour during maintenance. Generalized estimation equation analysis was used to compare the absolute temperature differences from $33^{\circ}C$ during the maintenance period. If the selected temperature was not between $32^{\circ}C$ and $34^{\circ}C$, the hour was considered a deviation from the target. We compared the deviation rates during hypothermia maintenance to evaluate the safety of the different methods. Results: A GP was used for 23 patients among of 53 patients, and a WB was used for the remaining. There was no difference in baseline temperature at the start of cooling between the two patient groups (GP, $35.7^{\circ}C$ vs. WB, $35.6^{\circ}C$; P=0.741). The time to target temperature (134.2 minutes vs. 233.4 minutes, P=0.056) was shorter in the GP patient group. Deviation from maintenance temperature (2.0% vs. 23.7%, P<0.001) occurred significantly more frequently in the WB group. The mean absolute temperature difference from $33^{\circ}C$ during the maintenance period was $0.19^{\circ}C$ (95% confidence interval [CI], $0.17^{\circ}C$ to $0.21^{\circ}C$) in the GP group and $0.76^{\circ}C$ (95% CI, $0.71^{\circ}C$ to $0.80^{\circ}C$) in the WB group. GP significantly decreased this difference by $0.59^{\circ}C$ (95% CI, $0.44^{\circ}C$ to $0.75^{\circ}C$; P<0.001). Conclusions: The GP was superior to the WB for strict temperature control during TTM.

신생아의 직장체온과 고막 및 액와체온과의 비교 (Comparison of Rectal Temperature with Axillary and Tympanic Temperature)

  • 황진순;송경애
    • 기본간호학회지
    • /
    • 제4권2호
    • /
    • pp.351-358
    • /
    • 1997
  • Body temperature should be measured accurately to assess neonate's condition for proper care. Temperatures measured in rectal, axillary and tympanic site were compared in 129 normal neonates to find out proper nursing time for measuring temperature and the validity of fever detection. The results were as follows : 1. Mean temperatures of axillary and tympanic site($36.85^{\circ}C,\;37.12^{\circ}C$) were significantly lower than those of rectal site($37.19^{\circ}C$). 2. Mean nursing time for measuring body temperature was significantly higher and lower in axillary and tympanic temperatures(159.49 seconds, 11.07 seconds) than in rectal temperature(105.62 seconds). 3. Tympanic and axillary temperatures were significantly correlated with rectal temperature (r=0.85, r=0.78) and the significant correlation was demonstrated between tympanic and axillary temperatures(r=0.76). 4. Sensitivity, specificity, positive and negative predictive values were 0.87, 0.90, 0.72, 0.96 for detecting fever respectively. The above findings indicated that the tympanic thermometer offers a useful alternative to conventional methods.

  • PDF

심장외과 중환자실 일반간호사의 업무분석 (Job Analysis of the Staff Nurse in Cardiac Surgery Intensive Care Unit)

  • 고유경
    • 간호행정학회지
    • /
    • 제9권2호
    • /
    • pp.265-282
    • /
    • 2003
  • Purpose : This study was conducted to provide for a basic resource, which can be used to set up a efficient management system in Cardiac Surgery Intensive Care Units(CSICU). Method: 1) Questionnaires were administered and observation methods were used, to examine the nursing activities performed in the CSICU after having reviewed related literatures and a review by the experts. Thus, the nursing activities were designating 254 activities and classified into 28 categories. 2)The 22 nurses in the 2 CSICUs filled out questionnaires about nursing activities from 12 April, 2002 to 17 April, 2002. The frequency of the nursing activities in the 28 categories counted and new nursing activities added by directly observing 12 nurses by two trained research staffs for 4 day. 3)In terms of validity, the 264 nursing activities were analysed by the 25 experts. As a result, 231 nursing activities were found valid and remained as appropriate nursing activities to be used for the careful analysis of the nursing activities in CSICUs. Result: The 22 categories are as below: assessment, monitoring, respiration management, nutrition management, elimination/drainage management, mobility management, sanitation management, safety management, temperature management, specimens collection, preparation and assistance of treatment, skin/wound management, infection management, medication management, education/support, dying patient care, recording/keeping, supplies management, environment management, communications, evaluations, professional development Conclusion : The manifest job description of the staff nurse will contribute to improving the efficiency of the nursing activities and to reducing the role conflicts among the medical staffs.

  • PDF

Design and Fabrication of Low Power Sensor Network Platform for Ubiquitous Health Care

  • Lee, Young-Dong;Jeong, Do-Un;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1826-1829
    • /
    • 2005
  • Recent advancement in wireless communications and electronics has enabled the development of low power sensor network. Wireless sensor network are often used in remote monitoring control applications, health care, security and environmental monitoring. Wireless sensor networks are an emerging technology consisting of small, low-power, and low-cost devices that integrate limited computation, sensing, and radio communication capabilities. Sensor network platform for health care has been designed, fabricated and tested. This system consists of an embedded micro-controller, Radio Frequency (RF) transceiver, power management, I/O expansion, and serial communication (RS-232). The hardware platform uses Atmel ATmega128L 8-bit ultra low power RISC processor with 128KB flash memory as the program memory and 4KB SRAM as the data memory. The radio transceiver (Chipcon CC1000) operates in the ISM band at 433MHz or 916MHz with a maximum data rate of 76.8kbps. Also, the indoor radio range is approximately 20-30m. When many sensors have to communicate with the controller, standard communication interfaces such as Serial Peripheral Interface (SPI) or Integrated Circuit ($I^{2}C$) allow sharing a single communication bus. With its low power, the smallest and low cost design, the wireless sensor network system and wireless sensing electronics to collect health-related information of human vitality and main physiological parameters (ECG, Temperature, Perspiration, Blood Pressure and some more vitality parameters, etc.)

  • PDF

The Effects of Kangaroo Care on Maternal Self-esteem and Premature Infants' Physiological Stability

  • Lee, Ji-Hye;Bang, Kyung-Sook
    • 여성건강간호학회지
    • /
    • 제17권5호
    • /
    • pp.454-462
    • /
    • 2011
  • Purpose: This paper identified the effects of kangaroo care (KC) on maternal self-esteem and the growth and physiological stability of premature infants hospitalized in the neonatal intensive care unit. Methods: The experiment was conducted with an experimental group of 17 infants, and a control group of 17 infants selected by convenience sampling. KC was given to the infants one time a day for 30 minutes after feeding for two weeks. Their weight was measured every morning, and their physiological stability was measured in terms of their body temperature, respiratory rate, heart rate, oxygen saturation, and stability of the cardio-respiratory system in premature infants (SCRIP) score, as physiological responses at every 10 minutes during the intervention. Maternal self-esteem was assessed by a maternal self-report inventory. Results: The experimental group showed significant increase in the self-esteem of mothers. Also, KC was effective on physiological stabilization of preterm infants. Conclusion: This study suggests that KC can be provided in clinical settings more widely in Korea as one of the nursing interventions aimed at promoting maternal self-esteem as well as infants' physiological stabilization.

연하장애를 가진 급성기 뇌졸중환자의 캡사이신을 이용한 구인두 감각 자극의 효과 (Effect of Oropharyngeal Sensory Stimulation Using Capsaicin in Acute Stroke Patients with Dysphagia)

  • 배한솔;이은남
    • 중환자간호학회지
    • /
    • 제14권3호
    • /
    • pp.73-86
    • /
    • 2021
  • Purpose : This study aimed to investigate the effects of oropharyngeal sensory stimulation using low-temperature capsaicin on dysphagia, dietary level, aspiration pneumonia, and nutritional status in acute stroke patients with dysphagia admitted to a stroke intensive care unit. Methods : This study used a randomized controlled trial design and 43 participants were randomly assigned to the experimental group (n=21) or control group (n=22). An oropharyngeal sensory stimulation intervention program was constructed based on previous studies. The intervention was provided before meals twice a day for seven days and started with the first meal after hospitalization. In the control group, a solution was made using only bottled water without adding capsaicin solution, and the intervention was provided at the same time, method, and number of times as the experimental group. Results : As a result of the study, dysphagia and dietary level improved in the experimental group that received oropharyngeal sensory stimulation using capsaicin. There were no effects on the nutritional status or aspiration pneumonia. Conclusion : This study provides basic data for the development of an intervention program for patients with dysphagia by presenting a theoretical basis that oropharyngeal sensory stimulation intervention using capsaicin improves dysphagia and dietary levels.

패치형 무선 피부 온도 측정 시스템의 설계 및 구현 (Design and implement of patch type wireless skin temperature measuring system)

  • 우상효;박수영;지아 모이 우딘;원철호;이정현;박희준;이정우;홍영진;서진호;염영일;조진호
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.350-360
    • /
    • 2008
  • In every large hospital, nurses must perform simple repetitive tasks such as measuring body temperature. Such tedious work reduces nurses' motivation to provide quality medical care, which is an important element of the medical services provided by a hospital. If a device were available to measure body temperature, nurses could focus on the more important aspects of providing quality medical care to the patients. However, body temperature is generally measured from the throat, anus, tympanum or armpit, where it is difficult to affix a patch type device. In addition, general body temperature measuring points shows moving artifact error; therefore, it is not good point to continually measure the temperature. In this paper, a patch type skin temperature measuring system was developed. To appropriately measure the skin temperature, a thermal transducer was implemented with a thin (0.5 mm) temperature sensor. The system is small and thin ($H6.6{\sim}5.3{\times}L35{\times}W24\;mm$), and weighs only 5 g including a battery, case and circuit; therefore, it is small and light enough to function as a patch type device. Moreover, the system worked for 5 days. To investigate differences between the experimental and conventional thermometer, simple clinical experiments were performed with 17 volunteers, and the result showed some correlation between the implemented system and conventional thermometer (Correlation coefficient = 0.647, P<0.1).