• Title/Summary/Keyword: Cardiovascular magnetic resonance imaging

Search Result 87, Processing Time 0.031 seconds

Guidelines for Cardiovascular Magnetic Resonance Imaging from Korean Society of Cardiovascular Imaging (KOSCI) - Part 1: Standardized Protocol

  • Jo, Yeseul;Kim, JeongJae;Park, Chul Hwan;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Kim, Pan Ki;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.296-315
    • /
    • 2019
  • Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.

Diagnosis of Right Ventricular Vegetation on Late Gadolinium-Enhanced MR Imaging in a Pediatric Patient after Repair of a Ventricular Septal Defect

  • Jeong, Jewon;Kim, Hae Jin;Kim, Sung Mok;Huh, June;Yang, Ji-Hyuk;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.114-119
    • /
    • 2016
  • We report a case of vegetation in a 4-year-old female with infective endocarditis, diagnosed by late gadolinium-enhanced (LGE) cardiovascular magnetic resonance (CMR) imaging. The patient had a history of primary closure for ventricular septal defect and presented with mild febrile sensation. No remarkable clinical symptoms or laboratory findings were noted; however, transthoracic echocardiography demonstrated a 14 mm highly mobile homogeneous mass in the right ventricle. On LGE CMR imaging, the mass showed marginal rim enhancement, which suggested the diagnosis of vegetation rather than thrombus. The extracellular volume fraction (${\geq}42%$) of the lesion was higher than that of normal myocardium. Based on the patient's clinical history of congenital heart disease and pathologic confirmation of the lesion, a diagnosis of infective endocarditis with vegetation was made.

Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 2: Interpretation of Cine, Flow, and Angiography Data

  • Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Jo, Yeseul;Kim, Jeong Jae;Park, Chul Hwan;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.316-327
    • /
    • 2019
  • Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technology advances and the expanded national insurance coverage of these tests. For improved patient care, it is crucial not only that CMR images are properly acquired but that they are accurately interpreted by well-trained personnel. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology (KSR). KOSCI has also created a formal Committee on CMR Guidelines to write updated practices. The members of this Committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.

Detection of Perivalvular Abscess with Late Gadolinium-Enhanced MR Imaging in a Patient with Infective Endocarditis

  • Ryu, Seong-Yoon;Kim, Hae Jin;Kim, Sung Mok;Park, Sung-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.75-79
    • /
    • 2016
  • We report a case of perivalvular abscess in a 66-year-old man with infective endocarditis, diagnosed by late gadolinium-enhanced (LGE) cardiovascular magnetic resonance (CMR) imaging. No clinical features suspicious of infective endocarditis were noted, however, transthoracic echocardiography revealed non-specific echogenic focal wall thickening at mitral-aortic intervalvular fibrosa. Perivalvular abscess in the aortic valve was demonstrated as focal wall thickening between the anterior mitral leaflet and the non-coronary cusp of the aortic valve with peripheral enhancement and central low signal intensity on LGE CMR imaging. Other features suggestive of infective endocarditis, such as neither vegetation nor valvular perforation were present. The perivalvular abscess did not grow after intensive intravenous antibiotics therapy, and the patient was discharged without surgical treatment. CMR with LGE provided an early accurate diagnosis of perivalvular abscess. The diagnosis of perivalvular abscess using LGE CMR imaging was not previously reported in Korea.

Magnetic Resonance Imaging in Thoracic Disease (흉부질환의 자기공명영상)

  • Song, Koun-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.345-352
    • /
    • 1993
  • The role of magnetic resonance(MR) imaging in the evaluation of thoracic disease has been limited Nontheless, MR has inherent properties of better contrast resolution than CT allowing tissue-specific diagnosis. MR has capability of direct imaging in sagittal, coronal, and oblique planes which provide better anatomic information than axial images of CT such as lesions in the pulmonary apex, aorticopulmonary window, peridiaphragmatic region, and subcarinal region. MR is sensitive to blood flow making it an ideal imaging modality for the evaluation of cardiovascular system of the thorax without the need for intravenous contrast media. Technical developments and better control of motion artifacts have resulted in improved image quality, and clinical applications of MR imaging in thoracic diseases have been expanded. Although MR imaging is considered as a problem-solving tool in patients with equivocal CT findings, MR should be used as the primary imaging modality in the following situations: 1) Evaluation of the cardiovascular abnormalities of the thorax 2) Evaluation of the superior sulcus tumors 3) Evaluation of the chest wall invasion or mediastinal invasion by tumor 4) Evaluation of the posterior mediastinal mass, especially neurogenic tumor 5) Differentiation of fibrosis and residual or recurrent tumor, especially in lymphoma 6) Evaluation of brachial plexopathy With technical developments and fast scan capabilities, clinical indications for MR imaging in thorax will increase in the area of pulmonary parenchymal and pulmonary vascular imaging.

  • PDF

Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 3: Perfusion, Delayed Enhancement, and T1- and T2 Mapping

  • Im, Dong Jin;Hong, Su Jin;Park, Eun-Ah;Kim, Eun Young;Jo, Yeseul;Kim, Jeong Jae;Park, Chul Hwan;Yong, Hwan Seok;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.1
    • /
    • pp.1-20
    • /
    • 2020
  • This document is the third part of the guidelines for the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by a Consensus Committee of the Korean Society of Cardiovascular Imaging (KOSCI) to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment, consisting of "What-to-See," "How-To," and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.

Computed Tomography and Magnetic Resonance Imaging Findings of Bicuspid Aortic Valve and Related Abnormalities of the Heart and Thoracic Aorta

  • You Jin You;Sung Min Ko
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.960-973
    • /
    • 2023
  • The bicuspid aortic valve (BAV) is the most common congenital cardiovascular malformation. Patients with BAV are at higher risk of other congenital cardiovascular malformations and valvular dysfunction, including aortic stenosis/regurgitation and infective endocarditis. BAV may also be related to aortic wall abnormalities such as aortic dilatation, aneurysm, and dissection. The morphology of the BAV varies with the presence and position of the raphe and is associated with the type of valvular dysfunction and aortopathy. Therefore, accurate diagnosis and effective treatment at an early stage are essential to prevent complications in patients with BAV. This pictorial essay highlights the characteristics of BAV and its related congenital cardiovascular malformations, valvular dysfunction, aortopathy, and other rare cardiac complications using multimodal imaging.

Dilated Cardiomyopathy in Acromegaly: a Case Report with Cardiac MR Findings

  • Kim, Min Seon;Choi, Hye Won;Seo, Yoon Seok;Lee, Whal;Park, Eun Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.395-400
    • /
    • 2019
  • Acromegaly is a rare endocrine disorder caused by excessive secretion of the growth hormone. There is a wide range of clinical manifestations from somatic symptoms to respiratory or cardiac failure. Among them, cardiovascular involvement is a leading cause of morbidity and mortality. There are relatively few cases reporting cardiac magnetic resonance imaging (CMR) findings of cardiomyopathy in patients with acromegaly. Thus, we report a case of acromegaly showing dilated cardiomyopathy focusing on the findings of CMR.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

  • Willinek, Winfried A.
    • Proceedings of the KSMRM Conference
    • /
    • 2004.09a
    • /
    • pp.87-87
    • /
    • 2004
  • PDF