• 제목/요약/키워드: Cardiovascular imaging

검색결과 301건 처리시간 0.026초

Delayed Post-Traumatic Spinal Cord Infarction with Quadriplegia: A Case Report

  • Kim, Tae Hoon
    • Journal of Trauma and Injury
    • /
    • 제34권4호
    • /
    • pp.279-283
    • /
    • 2021
  • Traumatic spinal cord infarction is a rare condition that causes serious paralysis. The regulation of spinal cord blood flow in injured spinal cords remains unknown. Spinal cord infarction or ischemia has been reported after cardiovascular interventions, scoliosis correction, or profound hypotension. In this case, a 52-year-old man revisited the emergency center with motor and sensory abnormalities in all four extremities 56 hours after a motor vehicle collision. Despite the clinical presentation and imaging examination, there were no specific findings on the patient's first visit to the trauma center. Cervical spine computed tomography angiography showed a narrow vertebral artery, and diffusion-weighted imaging revealed spinal cord infarction from C3 to C5 with high signal intensity. It should be kept in mind that delayed-onset spinal cord infarction may occur in minor or major trauma patients as a result of head and neck injuries.

Carbon Nanotubes Multi Electrodes Array to Image Capacitance for Label-free Discrimination of Lipid Region in Atherosclerosis ex vivo

  • 송준호;이선미;한날애;유경화
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.372.1-372.1
    • /
    • 2016
  • Recently, there are a lot of diseases all around the world. Out of them, Atherosclerosis (AS) is the most common cause of stroke, cardiovascular mortality, and myocardial infarction. The macrophage-derived foam cell, which is formed by oxidized low-density lipoprotein (oxLDL), is the crucial marker for AS. In this study, we report a label-free capacitance imaging technique with multi-electrode array (MEA). The lipid-rich aorta arch lesions, which are derived from an apolipoprotein-E receptor-deficient (apoE-/-) mouse, exhibit higher capacitance than the lipid-free aorta arch, allowing the capacitance imaging of lipid region in atherosclerosis. To improve the contacts between MEA and tissue, polypyrrole(PPy)-coated multi walled carbon nanotubes (MWNTs) multi electrode array (PPy-MWNTs-MEA) was fabricated. Compared to TiN-MEA, PPy-MWNTs-MEA yielded lower contact impedance and better capacitance images. In addition, we have also developed a flexible MEA using single walled carbon nanotubes on a PET substrate. The lipid region could be discriminated in the capacitance images of the lipid-rich aorta arch lesions measured using flexible MEA, demonstrating a feasibility of in vivo applications.

  • PDF

경식도 심초음파 검사를 이용한 판막대치술 환자의 평가 (Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제24권3호
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

Outcomes and Patency of Complex Configurations of Composite Grafts Using Bilateral Internal Thoracic Arteries

  • Shih, Beatrice Chia-Hui;Chung, Suryeun;Kim, Hakju;Chang, Hyoung Woo;Kim, Dong Jung;Lim, Cheong;Park, Kay-Hyun;Kim, Jun Sung
    • Journal of Chest Surgery
    • /
    • 제53권2호
    • /
    • pp.64-72
    • /
    • 2020
  • Background: It is generally agreed that using a bilateral internal thoracic artery (BITA) composite graft improves long-term survival after coronary artery bypass grafting (CABG). Although the left internal thoracic artery (LITA)-based Y-composite graft is widely adopted, technical or anatomical difficulties necessitate complex configurations. We aimed to investigate whether BITA configuration impacts survival or patency in patients undergoing coronary revascularization. Methods: Between January 2006 and June 2017, 1,161 patients underwent CABG at Seoul National University Bundang Hospital, where the standard technique is a LITA-based Y-composite graft with the right internal thoracic artery (RITA) sequentially anastomosed to non-left anterior descending (LAD) targets. Total of 160 patients underwent CABG using BITA with modifications. Their medical records and imaging data were reviewed retrospectively to investigate technical details, clinical outcomes, and graft patency. Results: Modifications of the typical Y-graft (group 1, n=90), LITA-based I-graft (group 2, n=39), and RITA-based composite graft (group 3, n=31) were used due to insufficient RITA length (47%), problems using LITA (28%), and target vessel anatomy (25%). The overall 30-day mortality rate was 1.9%. Among 116 patients who underwent computed tomography or conventional angiography at a mean interval of 29.9±33.1 months postoperatively, the graft patency rates were 98.7%, 95.3%, and 83.6% for the LAD, left circumflex artery, and right coronary artery territories, respectively. Patency rates for the inflow, secondary, and tertiary grafts were 98.2%, 90.5%, and 80.4%, respectively. The RITA-based graft (group 3) had the lowest patency rate of the various configurations (p<0.011). Conclusion: LITA-based Y composite graft, showed satisfactory clinical outcomes and patency whereas modifications of RITA- based composite graft had the lowest patency and 5-year survival rates. Therefore, when using RITA-based composite graft, other options should be considered before proceeding atypical configurations.

Role of Myocardial Extracellular Volume Fraction Measured with Magnetic Resonance Imaging in the Prediction of Left Ventricular Functional Outcome after Revascularization of Chronic Total Occlusion of Coronary Arteries

  • Yinyin Chen;Xinde Zheng;Hang Jin;Shengming Deng;Daoyuan Ren;Andreas Greiser;Caixia Fu;Hongxiang Gao;Mengsu Zeng
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.83-93
    • /
    • 2019
  • Objective: The purpose of this study was to prospectively investigate the value of the myocardial extracellular volume fraction (ECV) in predicting myocardial functional outcome after revascularization of coronary chronic total occlusion (CTO). Materials and Methods: Thirty patients with CTO underwent cardiovascular magnetic resonance (CMR) before and 6 months after revascularization. Three baseline markers of functional outcome were evaluated in the dysfunctional segments assigned to the CTO vessels: ECV, transmural extent of infarction (TEI), and unenhanced rim thickness (RIM). At the global level, the ECV values of the whole myocardium with and without a hyperenhanced region (global and remote ECV) were respectively measured. Results: In per-segment analysis, ECV was superior to TEI and RIM in predicting functional recovery (area under receiver operating characteristic curve [AUC]: 0.86 vs. 0.75 and 0.73, all p values < 0.010), and it emerged as the only independent predictor of regional functional outcome (odds ratio [OR] = 0.83, 95% confidence interval [CI]: 0.77-0.89; p < 0.001) independent of collateral circulation. In per-patient analysis, global baseline ECV was indicative of ejection fraction (EF) at the follow-up examination (β = -0.61, p < 0.001) and changes in EF (β = -0.57, p = 0.001) in multivariate regression analysis. A patient with global baseline ECV less than 30.0% (AUC, 0.93; sensitivity 94%, specificity 80%) was more likely to demonstrate significant EF improvement (OR: 0.38; 95% CI: 0.17-0.85; p = 0.019). Conclusion: Extracellular volume fraction obtained by CMR may provide incremental value for the prediction of functional recovery both at the segmental and global levels in CTO patients, and may facilitate the identification of patients who can benefit from revascularization.

Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020

  • Cherry Kim;Chul Hwan Park;Do Yeon Kim;Jaehyung Cha;Bae Young Lee;Chan Ho Park;Eun-Ju Kang;Hyun Jung Koo;Kakuya Kitagawa;Min Jae Cha;Rungroj Krittayaphong;Sang Il Choi;Sanjaya Viswamitra;Sung Min Ko;Sung Mok Kim;Sung Ho Hwang;Nguyen Ngoc Trang;Whal Lee;Young Jin Kim;Jongmin Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • 제23권3호
    • /
    • pp.298-307
    • /
    • 2022
  • Objective: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. Materials and Methods: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). Results: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. Conclusion: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.

페리틴 리포터 유전자를 발현하는 백서 중간엽 줄기세포의 특성과 자기공명영상 연구 ($In$ $vitro$ MRI and Characterization of Rat Mesenchymal Stem Cells Transduced with Ferritin as MR Reporter Gene)

  • 신청일;이활;우지수;박은아;김판기;송현복;김회숙
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.47-54
    • /
    • 2012
  • 목적: 백서 중간엽 줄기세포에 페리틴 유전자를 형질 도입시켜 생물학적 특성의 변화 유무를 평가하고, 자기공명영상에서 신호강도의 차이를 확인해보고자 하였다. 대상과 방법: 백서 중간엽 줄기세포에 렌티바이러스를 이용하여 사람유래 재조합 페리틴과 녹색형광단백질 유전자의 과발현을 유도하였다. 페리틴 유전자가 발현된 백서 중간엽 줄기세포의 증식성과 생존능을 분석하기 위해 MTT 어세이를 수행하였으며, 유세포 분석을 수행하여 중간엽 줄기세포의 표면 마커 발현을 평가하고, 세포 내 철 함량을 측정하고 프러시안 블루 염색을 시행하여 철 축적능력을 분석하였다. 세포 팬텀을 이용하여 9.4 T 자기공영영상 기기를 이용하여 검출가능성을 평가하였다. 결과: 페리틴과 녹색형광 유전자는 백서 중간엽 줄기세포에서 안정적으로 발현되었다. 페리틴 유전자의 과발현으로 인해 백서 중간엽 줄기세포의 생물학적 특성 (증식능력, 생존능, 표면마커)은 영향을 받지 않았다. 페리틴을 발현하는 중간엽 줄기세포에서 철의 축적능력이 증가된 것이 확인되었고, T2 이완 시간은 유의하게 감소하였다. 결론: 줄기세포 치료 연구에서 자기공명 리포터 유전자 페리틴은 자기공명영상법을 이용하여 중간엽 줄기세포를 비침습적으로 가시화 할 수 있고 이를 이용하여 생체추적이 가능할 것으로 기대된다.

Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy

  • Min Jae Cha;Iksung Cho;Joonhwa Hong;Sang-Wook Kim;Seung Yong Shin;Mun Young Paek;Xiaoming Bi;Sung Mok Kim
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1044-1053
    • /
    • 2021
  • Objective: Motion-corrected averaging with a single-shot technique was introduced for faster acquisition of late-gadolinium-enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging while free-breathing. We aimed to evaluate the image quality (IQ) of free-breathing motion-corrected single-shot LGE (moco-ss-LGE) in patients with hypertrophic cardiomyopathy (HCM). Materials and Methods: Between April and December 2019, 30 patients (23 men; median age, 48.5; interquartile range [IQR], 36.5-61.3) with HCM were prospectively enrolled. Breath-held single-shot LGE (bh-ss-LGE) and free-breathing moco-ss-LGE images were acquired in random order on a 3T MR system. Semi-quantitative IQ scores, contrast-to-noise ratios (CNRs), and quantitative size of myocardial scar were assessed on pairs of bh-ss-LGE and moco-ss-LGE. The mean ± standard deviation of the parameters was obtained. The results were compared using the Wilcoxon signed-rank test. Results: The moco-ss-LGE images had better IQ scores than the bh-ss-LGE images (4.55 ± 0.55 vs. 3.68 ± 0.45, p < 0.001). The CNR of the scar to the remote myocardium (34.46 ± 11.85 vs. 26.13 ± 10.04, p < 0.001), scar to left ventricle (LV) cavity (13.09 ± 7.95 vs. 9.84 ± 6.65, p = 0.030), and LV cavity to remote myocardium (33.12 ± 15.53 vs. 22.69 ± 11.27, p < 0.001) were consistently greater for moco-ss-LGE images than for bh-ss-LGE images. Measurements of scar size did not differ significantly between LGE pairs using the following three different quantification methods: 1) full width at half-maximum method; 23.84 ± 12.88% vs. 24.05 ± 12.81% (p = 0.820), 2) 6-standard deviation method, 15.14 ± 10.78% vs. 15.99 ± 10.99% (p = 0.186), and 3) 3-standard deviation method; 36.51 ± 17.60% vs. 37.50 ± 17.90% (p = 0.785). Conclusion: Motion-corrected averaging may allow for superior IQ and CNRs with free-breathing in single-shot LGE imaging, with a herald of free-breathing moco-ss-LGE as the scar imaging technique of choice for clinical practice.

3D프린팅 기술을 이용한 심혈관 질환 진단의 유용성 평가 (Evaluating the Usefulness of Diagnosis through 3D Printing Technology)

  • 박천규;김정훈
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.691-696
    • /
    • 2021
  • 환자의 질병을 예방 및 치료를 위해서는 의료영상을 통한 병변의 해부학적 구조 파악은 중요한 과정중 하나이다. 하지만 스크린으로 통해 보여 지는 영상으로는 한계가 있으므로 3D 프린팅 기술을 이용하여 이를 극복하고자 하는 많은 연구가 진행 중이다. 이를 위해 본 연구는 실제 환자 영상데이터를 이용하여 3차원 심혈관 모델을 구현하였고, 이를 3D 프린터를 이용하여 출력하여 현재 종사하고 있는 의료전문가에게 유용성 테스트를 진행하였다. 유용성 평가 결과 총 5인이 실시한 설문을 리커트 척도로 변환하였을 때 모든 항목 평균값이 4.83점의 높은 결과를 나타내고, 교차분석 결과 x2(P)=10.000(0.265)의 수치로 모든 설문자간 동일하게 긍정적인 설문 결과를 나타냈다. 결과를 바탕으로 3D프린팅 기술이 의료기술 발전에 도움을 줄 것으로 기대한다.