• Title/Summary/Keyword: Cardiac valve prosthesis

Search Result 56, Processing Time 0.026 seconds

Clinical Evaluation of the ATS Valve Replacement (ATS 기계판막의 단기 임상성적)

  • 김학제;조성준
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.293-299
    • /
    • 1997
  • With the introduction of new cardiac prosthesis, it behooves surgeons and cardiologists to monitor its performance carefully. ATS (Advancing The Standard) prosthetic valve has been used first in Guro hospital in Korea, since August 1994. Between August 1994 and July 1995, 21 patients received 28 ATS prosthesis(9 aortic, 19 mitral).19mi1ra1 valves were implanted through the "Extended Transseptal Approach" 10 were ma e and 11 were female, ranging from 20 to 54 years of age(Mean age : 37 years). The follow up period 126 patient-months(mean 6.1 months), varied from 1 month to 12 months. NYHA functional class was improved significantly, from $2.9\pm0.7$ preoperatively to $1.4\pm0.5$ postoperatively. Ejection fraction was also improved from $55.5\pm6.1%$ preoperatively to 59.8 $\pm7.4%$ postoperatively. Lactic dehydrogenase(LDH) was used as an indicator of hemolysis. The value of LDH changed from 483.3 $\pm$ 162 lUlL preoperatively to $527\pm274$ lUff postoperatively with no clinical significailce. Valve related complications, such as thromboembolism, valve thrombosis, anticoagulant related hemorrhage and prosthetic valve endocarditis did not develop except one anticoagulant related intracranial hemorrhage. There were no mortalities. This experience encourages us to continue using the ATS prosthetic valve, and this study will help those patients who need to have their heart valves replaced. replaced.

  • PDF

Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases- (인공심장판막의 재치환술)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF

Mechanical versus Tissue Aortic Prosthesis in Sexagenarians: Comparison of Hemodynamic and Clinical Outcomes

  • Son, Jongbae;Cho, Yang Hyun;Jeong, Dong Seop;Sung, Kiick;Kim, Wook Sung;Lee, Young Tak;Park, Pyo Won
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.100-108
    • /
    • 2018
  • Background: The question of which type of prosthetic aortic valve leads to the best outcomes in patients in their 60s remains controversial. We examined the hemodynamic and clinical outcomes of aortic valve replacement in sexagenarians according to the type of prosthesis. Methods: We retrospectively reviewed 270 patients in their 60s who underwent first-time aortic valve replacement from 1995 to 2011. Early and late mortality, major adverse valve-related events, anticoagulation-related events, and hemodynamic outcomes were assessed. The mean follow-up duration was $58.7{\pm}44.0$ months. Results: Of the 270 patients, 93 had a mechanical prosthesis (mechanical group), and 177 had a bioprosthesis (tissue group). The tissue group had a higher mean age and prevalence of preoperative stroke than the mechanical group. The groups had no differences in the aortic valve mean pressure gradient (AVMPG) or the left ventricular mass index (LVMI) at 5 years after surgery. In a sub-analysis limited to prostheses in the supra-annular position, the AVMPG was higher in the tissue group, but the LVMI was still not significantly different. There was no early mortality. The 10-year survival rate was 83% in the mechanical group and 90% in the tissue group. The type of aortic prosthesis did not influence overall mortality, cardiac mortality, or major adverse valve-related events. Anticoagulation-related events were more common in the mechanical group than in the tissue group (p=0.034; hazard ratio, 4.100; 95% confidence interval, 1.111-15.132). Conclusion: The type of aortic prosthesis was not associated with hemodynamic or clinical outcomes, except for anticoagulation-related events.

Viability Assay of Cardiac Allograft (I) (동종 동맥판의 생육성 평가에 관한연구(I))

  • 임창영
    • Journal of Chest Surgery
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Allograft cardiac valves have been used for over 30 years to replace diseased cardiac valves, reconstruct right or left ventricular outflow tract. With increasing its requirement, the establishment of a viable bank capable of maintaining the viability of graft over a prolonged period would be desirable. The method for determining the viability of allograft by metabolic assay technique using radiolabeled aminoacids has been used recently. An experimental study was done for evaluation of viability of cardiac allograft which was preserved for 14 days at 4oC in nutrient medium[fresh preservation] by metabolism assay technique using 3H-glycine. Also, the effectiveness of low concentration antibiotic solution[CLPV] for sterilization was evaluated. The effectiveness of CLPV solution for sterilization of allograft was perfect. Pre-treatment cultured organisms were not cultured after treatment at all in every cases. The viability of allograft after sterilization was reduced to 66.4%[aortic wall], 74.7%[pulmonary wall], 76.3%[aortic valve], 67.9%[aortic wall]. And after the fresh preservation for 14 days, the viability was reduced to 14.7%, 18.5%, 17.7%, 19.0%, respectively.In conclusion, viability of allograft was reduce to 71.3[66.4-76.3]% after sterilization and 17.5[14.7-19.0]% after fresh preservation. And sterilization effect of CLPV solution was satisfactory.

  • PDF

Clinical Experience of Medtronic-Hall Valve (Medtronic-Hall 기계판막의 임상경험)

  • 김종원;정성운
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1031-1036
    • /
    • 1998
  • Background: Medtronic-Hall mechanical valve is a world widely using prosthesis. But, in Korea, the clinical result from Medtronic-Hall valve replacement is not frequenthy available. Materials and methods: From March 1986 to May 1990, 50 patients underwent valve replacement surgery with Medtronic-Hall valve at Pusan National University Hospital. Seventeen were male and thirty three were female and ra nging in age from 16 to 70 years of age(mean=35 years). Results: The causes of valvular lesion were rheumatic in 43 patients, bicuspid aortic valve in 3 patients, degenerative lesion in three patients and bacterial endocarditis in one patient. The operative procedures were mitral valve replacement(MVR) in 38, aortic valve replacement(AVR) in 5 and double valve replacement(DVR) in 7. The most commonly used valve size was 21mm in AVR, 29mm in MVR. Concomitant surgical procedures were performed in 15 patients; left atrial thrombectomy in 9, left atrial auricle obliteration in 6 and tricuspid annuloplasty in 5(Kay: 2, DeVega: 3). New York Heart Association functional class was mostly Class Ⅲ or Ⅳ(91.5%) preoperatively and ClassⅠor Ⅱ(87.2%) after operation. The findings of postoperative echocardiogram of LAD, LVESD, LVEDD were reduced compared with preoperative period and ejection fraction was increased compared with preoperative period. Postoperative complications were massive bleeding in three, low cardiac output syndrome in two, thromboembolism in one and fulminant hepatitis in one patient. There were three hospital deaths and their causes were low cardiac output syndrome in two and rupture of left ventricle in one patient. The 5 year survival rate was 93.65±0.71% and 10 year actuarial survival rate was 88.27±6.42%. Conclusions: Medtronic-Hall mechanical valve has low valve related complication rate. It's durability and hemodynamic performance is comparable to other mechanical valves.

  • PDF

Surgical correction in annuloaortic ectasia associated with ascending aortic aneurysm: one case report (거대상행핵대동맥루를 동반한 대동맥륜확장증 수술 치험: Cabrol씨 수술 1례 보)

  • 곽문섭
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.753-761
    • /
    • 1984
  • Most patients having annuloaortic ectasia are associated with marked dilatation of the sinuses of Valsalva and the aortic annulus as well as the huge aneurysm of the ascending aorta. A 19 year old male patient complaining of tightness on left posterior chest wall underwent cardiac angiography in which demonstrated annuloaortic ectasia with ascending aortic aneurysm and aortic insufficiency. The patient had corrective operation replacing the ascending aorta and aortic valve with a composite graft[Dacron prosthesis containing a Bjork-Shiley aortic valve] within the aneurysmal sac. The coronary orifices were anastomosed to the tubular Dacron prosthesis [30 mm in diameter] by means of a second smaller Gore-Tex tube [8mm in diameter]. The aneurysmal sac was trimmed by removing the redundant wall and then wrapped outer wall of the Dacron prosthesis. Postoperatively, mediastinal bleeding was temporarily observed in the operative day and satisfactory blood pressure was maintained with small dose of dopamine. One week later, large amount of serous effusion was drained out of the retrosternal space making partial disruption of the skin which was healed well by daily local dressing. The patient discharged in good condition on postoperative 29th day with no residual complications and is doing very well on the 4 months follow-up.

  • PDF

Long-Term Clinical Results with the St. Jude Medical Cardiac Valve Prosthesis (St. Jude Medical판막치 환술의 장기 임상성적)

  • 김윤규;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.964-970
    • /
    • 1996
  • One hundred eight patients (Feb.'86, through Jan.'96) underwent 53 mitral(MVR), 20 aortic(AVR), )5 double(DVR) valve replacement with SJM prosthesis. There were 55 males and 53 females whose mean age was 36.3 $\pm$ 10.4 years. We used 143 valves in mitral(88), aortic(54), and tricuspid(1) sites. The size and number of valves were 31 mm(32). 33inm(23), 29mm(20), 27mm(10), 25mm(2), and 35mm(1) in mitral site; 2)mm(21), 21mm(1 S), 19mm(7), 25mm(5), 27mm(2), and 33mm(1) in aortic site; and Blmm(1) in tricuspid site. Preoperative NYHA functional classes were II(14), III(73) and IV(21), and which were improved into I(89) and II(16) postoperatively. Early postoperative complications occurred in 15 cases(13.9%) in which LOS was the most common one(5 cases; 4.6%). fatly hospital death occurred in 3 cases(2.8%) due to LOS(1) and sudden cardiac arrest(2) he cummulative total follow-up period was 437.6 pl-yr with a mean of 4.1$\pm$2.9 years. There were 5 events of valve related'complications (2 TE, 1 paravalvular leak, 1 TE+paravalvular leak, 1 PVE) with the occurrence rate as 1.14%/pt-yr. Reoperation was performed in 2 cases and there were 2 cases of valve related death due to one PVE and one paravalvlllar leak. The complication free rate was 91.4$\pm$ ).4% at 10 years. Actuarial survival rate was 93.6 $\pm$ 3.1 % at 10 years.

  • PDF

PIV Measurements of Flow Downstream of Polyurethane Heart Valve Prosthesis for Artificial Heart: Pulsatile Flow Experiment (PIV를 이용한 인공심장용 폴리우레탄 인공판막 하류의 유동 측정 : 맥동유동실험)

  • Yu, Jeong-Yeol;Kim, Jung-Gyeong;Seong, Jae-Yong;Jang, Jun-Geun;Min, Byeong-Gu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.629-639
    • /
    • 2002
  • In-vitro flow characteristics downstream of a polyurethane artificial heart valve and a Bjork-Shiley Monostrut mechanical valve have been comparatively investigated in pulsatile flow using particle image velocimetry (PIV). With a triggering system and a time-delayed circuit the velocity distributions on the two perpendicular measurement planes downstream of the valves are evaluated at any given instant in conjunction with the opening behaviors of valve leaflets during a cardiac cycle. The regions of stasis and high shear stress can be found simultaneously by examining the entire view of the instantaneous velocity and Reynolds shear stress fields. It is known that high shear stress regions exist at the interface between strong axial jet flows along the wall and vortical flows in the central area distal to the valves. In addition. there are large stagnation or recirculation regions in the vicinity of the valve leaflet, where thrombus formation can be induced by accumulation of blood elements damaged in the high shear stress zones. A correlation between the unsteady flow patterns downstream of the valve and the corresponding opening postures of the polyurethane valve membrane gives useful data necessary for improved design of the frame structure and leaflet geometry of the polyurethane valve.

A 6 Year Experience with the St. Jude Medical Cardiac Valve Prosthesis (St. Jude Medical 판을 이용한 심판막 치환술의 성적)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.296-306
    • /
    • 1992
  • A 6 year experience with the bileaflet St. Jude Medical valve is reported. Between Feb. 1986 and Dec. 1992, 68 patients received 87 such valves[36 mitral, 13 aortic, and 19 double mitral-aortic valve replacements]. The results are summarized as follows 1. There were 35 male and 33 female patients ranging in age from 17 to 55 years the mean age of 35.3 $\pm$ 9.7 years. 2. The mean aortic clamp time[ACT] of the MVR, AVR and DVR groups were 91.5$\pm$16.4, 117.2$\pm$28.7 and 165.5$\pm$24.1 minutes. The mean total bypass time [TBT] of the MVR, AVR and DVR groups were 112.8$\pm$19.5, 134.7$\pm$31.4 and 192.2$\pm$28.5 minutes. 3. Eighty seven valves were used [55 mitral site, 32 aortic site]. 31mm[20], 33mm[15], 29mm[15], 27mm[2], 25mm[2] and 35mm[1] were used in mitral site and 23mm[13], 21mm[8], 19mm[7] and 25mm[4] were used in the aortic site. In the DVR, there were valve combinations such as 4 cases of M[29mm]-A[19mm], 4 of M[31mm]-A[23mm], 3 of M[33mm]-A[23mm] and others. 4. Preoperative NYHA functional classes were II [3 cases], III [46 cases], IV[19 cases] and improved to I [52 cases] and Il [13 cases] postoperatively. 5 Early postoperative complications were occurred in 15 cases[2Z.l%] and there were LOS in 5 cases[7.4%], arrythmia [3 cases], wound infection [2 cases], hepatitis [2 cases], sudden cardiac arrest [2 cases] and postoperative bleeding [1 case]. The early hospital death was occurred in 3 cases[4.4%] with LOS [1 case] and sudden cardiac arrest [2 cases]. 6. Mean follow-up time of survival cases[65 cases] was 31.3$\pm$21.9 months and the total follow-up time was 169.8 patient-years. Late postoperative complications were occurred in 4 cases[2 thromboembolism, 1 paravalvular leak, 1 thromboembolism br paravalvular leak, 1 valve endocarditis] with the occurrence rate as 2.35% per patient-years. Reoperation was performed in 2 cases [1 paravalvular leak, 1 left atrial thrombus] and there was one [1.5%] late valve related death. Therefore the 6 year complication free rate was 90.6% and 6 year actuarial survival rate was 98.3$\pm$1.7%. On the basis of this experience and the results, SJMvalve appears to be one of the best performing mechanical prosthesis currently available, in terms of both hemodynamics and lower complications with warfarin antioagulation.

  • PDF

Reoperation for Dysfunction of Cardiac Valve Prosthesis (인공 심장판막 기능부전 환자에서의 심장판막 재치환술)

  • 윤정섭;김치경;조규도;이성호;곽문섭;김세화
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.242-246
    • /
    • 1998
  • From January 1988 to December 1995, 27 patients, 11 men and 16 women, underwent surgical intervention at our institution for prosthetic valve dysfunctions. The mean age was 43.5$\pm$12.2 years. Seventeen(63.0%) patients had the mitral valve replacement, 8(29.6%) the aortic valve, 1(3.7%) the aortic composite graft, and 1(3.7%) the tricuspid valve. Mean follow-up period was 49.5$\pm$30.9 months. In 12 bioprostheses, mean interval between the previous valve replacement and the reoperation was 104.9$\pm$34.9 months. The causes of redo surgery were structural deterioration of the prosthetic valve (12/12, 100%), paravalvular leak (2/12, 16.7%), and prosthetic valve endocarditis(1/12, 8.3%). In 15 mechanical prostheses, the mean interval was 55.2$\pm$43.7 months. The causes of redo surgery were pannus formation (8/15, 53.3%), paravalvular leak(4/15, 26.7%), and valve thrombosis(3/15, 20.0%). Posto- perative complications occurred in 7 patients (25.9%). There was no intraoperative death. But one patient, who received mechanical aortic valve replacement died on the 3rd postoperative day due to low cardiac output and multiorgan failure.

  • PDF