• Title/Summary/Keyword: Cardiac resynchronization therapy device

Search Result 3, Processing Time 0.017 seconds

Nonpharmacological treatment of arrhythmia (소아 부정맥의 비약물적 치료)

  • Bae, Eun-Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.930-936
    • /
    • 2006
  • Although antiarrhythmic medication has been the main treatment modality for arrhythmia in children, in recent decades technological development and computerization have made great advances in nonpharmacological therapy. This article reviews the transcatheter radiofrequency ablation for tachycardia in children, recent advances of device therapy for bradycardia, antitachycardia pacing, implantable cardioverter defibrillator. As a new field of device therapy, cardiac resynchronization therapy for congestive heart failure is also mentioned.

Clinical Implications of Device-Detected Atrial Fibrillation in Cardiac Resynchronization Therapy

  • Minjae Yoon;Jaewon Oh;Kyeong-Hyeon Chun;Hee Tae Yu;Chan Joo Lee;Tae-Hoon Kim;Hui-Nam Pak;Moon-Hyoung Lee;Boyoung Joung;Seok-Min Kang
    • Korean Circulation Journal
    • /
    • v.53 no.7
    • /
    • pp.483-496
    • /
    • 2023
  • Background and Objectives: Atrial fibrillation (AF) is associated with decreased cardiac resynchronization therapy (CRT) benefits compared to sinus rhythm (SR). Effective biventricular (BiV) pacing is a determinant of CRT success, but AF can interfere with adequate BiV pacing and affect clinical outcomes. We investigated the effect of device-detected AF on clinical outcomes and optimal BiV pacing in patients with heart failure (HF) treated with CRT. Methods: We retrospectively analyzed 174 patients who underwent CRT implantation between 2012 and 2019 at a tertiary center. The optimal BiV pacing percentage was defined as ≥98%. Device-detected AF was defined as an atrial high-rate episode ≥180 beats per minute lasting more than 6 minutes during the follow-up period. We stratified the patients without preexisting AF at pre-implantation into device-detected AF and no-AF groups. Results: A total of 120 patients did not show preexisting AF at pre-implantation, and 54 had AF. Among these 120 patients, 19 (15.8%) showed device-detected AF during a median follow-up of 25.1 months. The proportion of optimal BiV pacing was significantly lower in the device-detected AF group than in the no-AF group (42.1% vs. 75.2%, p=0.009). The devicedetected AF group had a higher incidence of HF hospitalization, cardiovascular death, and all-cause death than the no-AF group. The device-detected AF and previous AF groups showed no significant differences regarding the percentage of BiV pacing and clinical outcomes. Conclusions: For HF patients implanted with CRT, device-detected AF was associated with lower optimal BiV pacing and worse clinical outcomes than no-AF.

Transaxillary Subpectoral Placement of Cardiac Implantable Electronic Devices in Young Female Patients

  • Oh, Joo Hyun;Kim, Chae Min;Song, Seung Yong;Uhm, Jae Sun;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.44 no.1
    • /
    • pp.34-41
    • /
    • 2017
  • Background The current indications of cardiac implantable electronic devices (CIEDs) have expanded to include young patients with serious cardiac risk factors, but CIED placement has the disadvantage of involving unsightly scarring and bulging of the chest wall. A collaborative team of cardiologists and plastic surgeons developed a technique for the subpectoral placement of CIEDs in young female patients via a transaxillary approach. Methods From July 2012 to December 2015, subpectoral CIED placement via an axillary incision was performed in 10 young female patients, with a mean age of 25.9 years and mean body mass index of $20.1kg/m^2$. In the supine position, with the patient's shoulder abducted, an approximately 5-cm linear incision was made along one of the deepest axillary creases. The submuscular plane was identified at the lateral border of the pectoralis major, and the dissection continued over the clavipectoral fascia until the subpectoral pocket could securely receive a pulse generator. Slight upward dissection also exposed an entrance to the subclavian vein, allowing the cardiology team to gain access to the vein. One patient with dilated cardiomyopathy underwent augmentation mammoplasty and CIED insertion simultaneously. Results One case of late-onset device infection occurred. All patients were highly satisfied with the results and reported that they would recommend the procedure to others. Conclusions With superior aesthetic outcomes compared to conventional methods, the subpectoral placement of CIEDs via a transaxillary approach is an effective, single-incision method to hide operative scarring and minimize bulging of the device, and is particularly beneficial for young female or lean patients.