High-Resolution Numerical Simulation of Respiration-Induced Dynamic B0 Shift in the Head in High-Field MRI

  • Lee, So-Hee;Barg, Ji-Seong;Yeo, Seok-Jin;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.38-45
    • /
    • 2019
  • Purpose: To demonstrate the high-resolution numerical simulation of the respiration-induced dynamic $B_0$ shift in the head using generalized susceptibility voxel convolution (gSVC). Materials and Methods: Previous dynamic $B_0$ simulation research has been limited to low-resolution numerical models due to the large computational demands of conventional Fourier-based $B_0$ calculation methods. Here, we show that a recently-proposed gSVC method can simulate dynamic $B_0$ maps from a realistic breathing human body model with high spatiotemporal resolution in a time-efficient manner. For a human body model, we used the Extended Cardiac And Torso (XCAT) phantom originally developed for computed tomography. The spatial resolution (voxel size) was kept isotropic and varied from 1 to 10 mm. We calculated $B_0$ maps in the brain of the model at 10 equally spaced points in a respiration cycle and analyzed the spatial gradients of each of them. The results were compared with experimental measurements in the literature. Results: The simulation predicted a maximum temporal variation of the $B_0$ shift in the brain of about 7 Hz at 7T. The magnitudes of the respiration-induced $B_0$ gradient in the x (right/left), y (anterior/posterior), and z (head/feet) directions determined by volumetric linear fitting, were < 0.01 Hz/cm, 0.18 Hz/cm, and 0.26 Hz/cm, respectively. These compared favorably with previous reports. We found that simulation voxel sizes greater than 5 mm can produce unreliable results. Conclusion: We have presented an efficient simulation framework for respiration-induced $B_0$ variation in the head. The method can be used to predict $B_0$ shifts with high spatiotemporal resolution under different breathing conditions and aid in the design of dynamic $B_0$ compensation strategies.

Artifacts due to Retrograde Flow in the Artery and Their Elimination in 2D TOF MR Angiography (2D TOF 자기공명 혈관조영술에서 동맥혈류의 역류로 인한 영상훼손과 이의 제거)

  • Jung, K.J.;Lee, J.K.;Kim, S.K.;Park, S.H.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.38-42
    • /
    • 2001
  • Dark band artifacts are often observed in angiograms of arteries obtained by 2D time-of-flight (TOF) angiography with saturation of veins by presaturation RF pulses. At some arteries the arterial blood velocity varies in a triphasic pattern during a cardiac cycle. The arterial blood, that is saturated by presaturation RF pulses in the saturation band, can flow back into the imaging slice during the retrograde flow phase of the triphasic variation. When such saturated retrograde flow occurs during the acquisition of the central part of the K space, a signal void can result in base images and consequently dark band artifacts can appear in angiograms. This phenomenon is experimentally demonstrated by varying the gap between the imaging slice and the saturation band. Furthermore, a new pulse sequence is proposed to eliminate the dark band artifacts by changing the profile of the saturation band front a rectangle to a ramp.

  • PDF

Design of MRI Spectrometer Using 1 Giga-FLOPS DSP (1-GFLOPS DSP를 이용한 자기공명영상 스펙트로미터 설계)

  • 김휴정;고광혁;이상철;정민영;장경섭;이동훈;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • Purpose : In order to overcome limitations in the existing conventional spectrometer, a new spectrometer with advanced functionalities is designed and implemented. Materials and Methods : We designed a spectrometer using the TMS320C6701 DSP capable of 1 giga floating point operations per second (GFLOPS). The spectrometer can generate continuously varying complicate gradient waveforms by real-time calculation, and select image plane interactively. The designed spectrometer is composed of two parts: one is DSP-based digital control part, and the other is analog part generating gradient and RF waveforms, and performing demodulation of the received RF signal. Each recover board can measure 4 channel FID signals simultaneously for parallel imaging, and provides fast reconstruction using the high speed DSP. Results : The developed spectrometer was installed on a 1.5 Tesla whole body MRI system, and performance was tested by various methods. The accurate phase control required in digital modulation and demodulation was tested, and multi-channel acquisition was examined with phase-array coil imaging. Superior image quality is obtained by the developed spectrometer compared to existing commercial spectrometer especially in the fast spin echo images. Conclusion : Interactive control of the selection planes and real-time generation of gradient waveforms are important functions required for advanced imaging such as spiral scan cardiac imaging. Multi-channel acquisition is also highly demanding for parallel imaging. In this paper a spectrometer having such functionalities is designed and developed using the TMS320C6701 DSP having 1 GFLOPS computational power. Accurate phase control was achieved by the digital modulation and demodulation techniques. Superior image qualities are obtained by the developed spectrometer for various imaging techniques including FSE, GE, and angiography compared to those obtained by the existing commercial spectrometer.

  • PDF

Isolated Congenital Left Ventricular Diverticulum in Adults

  • Jung, Joon Chul;Oh, Hong Chul;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.355-358
    • /
    • 2015
  • Isolated congenital left ventricular diverticulum is a rare cardiac malformation. Here, we report the case of a 33-year-old woman who had suffered from recurrent transient ischemic attacks for 6 years. Preoperative cardiac magnetic resonance imaging and computed tomography angiography revealed a diverticulum near the apex. The diverticulum was successfully obliterated by cardiopulmonary bypass. We suggest that isolated congenital left ventricular diverticulum can be easily corrected with a low surgical risk by patch repair and plication techniques.

Late Gadolinium Enhancement of Left Ventricular Papillary Muscles in Patients with Mitral Regurgitation

  • Su Jin Lim;Hyun Jung Koo;Min Soo Cho;Gi-Byoung Nam;Joon-Won Kang;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1609-1618
    • /
    • 2021
  • Objective: Arrhythmogenic mitral valve prolapse (MVP) is an important cause of sudden cardiac death characterized by fibrosis of the papillary muscles or left ventricle (LV) wall, and an association between late gadolinium enhancement (LGE) of the LV papillary muscles and ventricular arrhythmia in MVP has been reported. However, LGE of the papillary muscles may be observed in other causes of mitral regurgitation, and it is not limited to patients with MVP. This study was to evaluate the association of LGE of the LV papillary muscles or ventricular wall on cardiac magnetic resonance imaging (CMR) and ventricular arrhythmia in patients with mitral regurgitation. Materials and Methods: This study included 88 patients (mean age ± standard deviation, 58.3 ± 12.0 years; male, 42%) with mitral regurgitation who underwent CMR. They were allocated to the MVP (n = 43) and non-MVP (n = 45) groups, and their LGE images on CMR, clinical characteristics, echocardiographic findings, and presence of arrhythmia were compared. Results: LV myocardial wall enhancement was more frequent in the MVP group than in the non-MVP group (28% vs. 11%, p = 0.046). Papillary muscle enhancement was observed in 7 (7.9%) patients. Of the 43 patients with MVP, 15 (34.8%) showed LGE in the papillary muscles or LV myocardium, including 12 (27.9%) with LV myocardial wall enhancement and 4 (9.3%) with papillary muscle enhancement. One patient with bilateral diffuse papillary muscle enhancement experienced sudden cardiac arrest due to ventricular fibrillation. Univariable logistic regression analysis showed that high systolic blood pressure (BP; odds ratio [OR], 1.05; 95% confidence interval [CI], 1.01-1.09; p = 0.027) and ventricular arrhythmia (OR, 6.84; 95% CI, 1.29-36.19; p = 0.024) were significantly associated with LGE of the papillary muscles. Conclusion: LGE of the papillary muscles was present not only in patients with MVP, but also in patients with other etiologies of mitral regurgitation, and it was associated with high systolic BP and ventricular arrhythmia. Papillary muscle enhancement on CMR should not be overlooked.

Multi-biological Signal-based Smart Trigger System for Cardiac MRI (다중 생체 신호를 이용한 심장 자기공명영상 스마트 트리거 시스템)

  • Yang, Young-Joong;Park, Jinho;Hong, Hye-Jin;Ahn, Chang-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.945-949
    • /
    • 2014
  • In cardiac magnetic resonance imaging (CMRI), heart and respiratory motions are one of main obstacles in obtaining diagnostic quality of images. To synchronize CMRI to the physiological motions, ECG and respiratory gatings are commonly used. In this paper multi-biological signal (ECG, respiratory, and SPO2) based smart trigger system is proposed. By using multi-biological signal, the proposed system is robust to the induced noise such as eddy current when gradient pulsing is continuously applied during the examination. Digital conversion of the multi-biological signal makes the system flexible in implementing smart and intelligent algorithm to detect cardiac and respiratory motion and to reject arrhythmia of the heart. The digital data is used for real-time trigger, as well as signal display, and data storage which may be used for retrospective signal processing.

Successful Removal of a Cardiac Fibroma in Infant (신생아에서 발생한 심장 섬유종의 외과적 치료 -1례 보고-)

  • Kim, Si-Ho;Jo, Beom-Gu;Hong, Yu-Seon
    • Journal of Chest Surgery
    • /
    • v.28 no.5
    • /
    • pp.491-494
    • /
    • 1995
  • A fibroma arising in the right ventricle outflow tract of a 14 month-old infant was successfully removed. The patient was first seen because of shortness of breath and tachycardia. Pertinent clinical and laboratory findings included a grade II/VI systolic murmur, blood pressure of 120/60 mmHg, slight cardiomegaly on chest X-ray, a mass obstructing the outflow tract of the right ventricle on echocardiography and magnetic resonance imaging. On october 30,1992, under cardiopulmonary bypass, a 4cm x 3cm x 3cm tumor was resected from the right ventricular outflow tract, together with a portion of the ventricular wall. Histologically, it was diagnosis as a fibroma. The patient was sent home on the 6th postoperative day following an uneventful recovery form the operation. Although cardiac fibroma is the second most common cardiac tumor in infancy and childhood, it is usually found in the left ventricle and one arising in the right ventricle is considered rare. Although it is a benign tumor, it could produce a severe cardiac dysfunction and even sudden death, depending on its size and location. With the advance in diagnostic techniques and operative management, there is a renewed interest in the early detection and operative removal of these tumors. The case herein presented is the first such case successfully managed and reported in the Korean literature.

  • PDF

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF

Cardiac Angiosarcoma on the Right Atrium: Two Cases

  • Park, Won-Kyoun;Jung, Sung-Ho;Lim, Ju-Yong
    • Journal of Chest Surgery
    • /
    • v.45 no.2
    • /
    • pp.120-123
    • /
    • 2012
  • We detected two cases of right atrial angiosarcoma that had a similar appearance on imaging studies. Although the surgical findings were similar for the two patients, one had a clear resection margin, while the other had tumor cells in the resection margin on frozen biopsy. We suggest that preoperative data on magnetic resonance imaging and computed tomography in patients with angiosarcomas may not predict the exact extent of surgical resection or prognostic outcomes.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.