• Title/Summary/Keyword: Cardiac artery stenosis

Search Result 111, Processing Time 0.018 seconds

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF