• 제목/요약/키워드: Cardiac Volume

검색결과 259건 처리시간 0.028초

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제50권2호
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

Cardiac Response to Head-Out Water Immersion in Man

  • Choi, Jang-Kyu;Park, Won-Kun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권3호
    • /
    • pp.253-261
    • /
    • 2000
  • Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time intervals. Ten men rested on a siting position in the air and in the water at $34.5^{circ}C$ for 30 min each. Their stroke volume, heart rate, ventricular systolic time intervals, and aortic blood flow indices were assessed by impedance cardiography. During immersion, the stroke volume increased 56%, with a slight (4%) decrease in heart rate, thus cardiac output increased ${\sim}50%.$ The slight increase in R-R interval was due to an equivalent increase in the systolic and diastolic time intervals. The ventricular ejection time was 20% increased, and this was mainly due to a decrease in pre-ejection period (28%). The mean arterial pressure increased 5 mmHg, indicating that the cardiac afterload was slightly elevated by immersion. The left ventricular end-diastolic volume index increased 24%, indicating that the cardiac preload was markedly elevated during immersion. The mean velocity and the indices of peak velocity and peak acceleration of aortic blood flow were all increased by ${\sim}30%,$ indicating that the left ventricular contractile force was enhanced by immersion. These results suggest that the increase in stroke volume during immersion is characterized by an increase in ventricular ejection time and aortic blood flow velocity, which may be primarily attributed to the increased cardiac preload and the muscle length-dependent increase in myocardial contractile force.

  • PDF

심장병 진단을 위한 실시간 디지탈 감산 조영 영상기법의 개발 (Development of Cardiac Digital Subtraction Angiographic System for Diagnosis of Cardiac Diseases)

  • 민병구;이태수
    • 대한전자공학회논문지
    • /
    • 제26권2호
    • /
    • pp.132-139
    • /
    • 1989
  • 본 연구에서는 심장의 박동영상을 방사선 투시법으로 관찰하여 심장질환을 진단하기 위한 실시간 처리 심장 디지탈 감산 조영 영상기법(cardiac digital subtraction angiography)을 개발하여 임상실험을 시행하였다. 평균 1초에 1번의 심장박동에 따른 주변부위의 운동에 의한 오차의 영향을 감소하면서, 좌심실 박동상을 32프레임까지 실시간으로 감산 처리하는 고속기억(512X512 해상도와 256 gray level) 및 고속 데이타링크 시스템과 프로세서를 개발하였다. 기억된 영상을 컴퓨터에 입력하고, 심장의 경계면을 Dynamic Programming을 사용하여 검출하고, 부피를 구하여 심장의 박동에 따른 최대부피(ESV)와 박동후 최소부피(ESV), 최대와 최소부피의 비율(EF)로서 표시되는 심박출계수 등 심장의 좌심실기능을 나타내는 생리계수를 영상으로 부터 구하는 알고리듬을 개발해서 임상실험을 시행하였다.

  • PDF

Effects of vasopressin administration in the oral cavity on cardiac function and hemodynamics in rats

  • Fukami, Hayato;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권1호
    • /
    • pp.11-18
    • /
    • 2022
  • Background: The vasoconstrictive effect of epinephrine in local anesthetics affects the heart, which leads to hesitation among dentists in injecting local anesthetics into patients with cardiovascular disease. Due to its vasoconstrictive effects, the present study investigated the effects of vasopressin administration on cardiac function in rats. Methods: Experiment 1 aimed to determine the vasopressin concentration that could affect cardiac function. An arterial catheter was inserted into the male Wistar rats. Next, 0.03, 0.3, and 3.0 U/mL arginine vasopressin (AVP) (0.03V, 0.3V, and 3.0V) was injected into the tongue, and the blood pressure was measured. The control group received normal saline only. In Experiment 2, following anesthesia infiltration, a pressure-volume catheter was placed in the left ventricle. Baseline values of end-systolic elastance, end-diastolic volume, end-systolic pressure, stroke work, stroke volume, and end-systolic elastance were recorded. Next, normal saline and 3.0V AVP were injected into the tongue to measure their effect on hemodynamic and cardiac function. Results: After 3.0V administration, systolic blood pressures at 10 and 15 min were higher than those of the control group; they increased at 10 min compared with those at baseline. The diastolic blood pressures at 5-15 min were higher than those of the control group; they increased at 5 and 10 min compared with those at baseline. The preload decreased at 5 and 10 min compared to that at baseline. However, the afterload increased from 5 to 15 min compared with that of the control group; it increased at 10 min compared with that at baseline. Stroke volume decreased at 10 and 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Stroke work decreased from 5 to 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Conclusion: Our results showed that 3.0 U/mL concentration of vasopressin resulted in increased blood pressure, decreased stroke volume and stoke work, decreased preload and increased afterload, without any effect on myocardial contractility.

소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가 (Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT)

  • 박기석;김동현
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.683-689
    • /
    • 2019
  • 소아의 선천적 심장질환 진단을 위해 High Pitch Mode를 사용하여 획득한 소아 심장 CT 영상과 Wide Coverage Volume Axial Mode를 사용하여 획득한 소아 심장 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Wide Coverage Volume Axial Mode의 유용성을 평가해보고자 한다. 소아 심장 CT 검사 시 High Pitch Mode와 Wide Coverage Volume Axial Mode를 각각 50명 총 100명의 환자를 대상으로 시행하였으며, 각 프로토콜로부터 얻은 영상을 이용하여 환자의 피폭선량을 비교하였다. 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상의 화질을 비교하였다. High Pitch Mode에 비해 Wide Coverage Volume Axial Mode를 사용하여 검사하였을 때 환자의 피폭선량이 13.07% 감소하였고, SNR과 CNR이 향상되었다. Wide Coverage Volume Axial Mode는 고속 회전 스캐너를 이용하여 조사시간을 줄이고, 저선량 기술인 ASi R-V를 통해 High Pitch Mode를 사용했을 때보다 환자의 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다.

Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.450-461
    • /
    • 2020
  • Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters. Materials and Methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods. Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA. Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

임피던스 방법을 이용한 심장 기능의 측정 (Measurement of Cardiac Function using Impedance Technique)

  • 김정얼;김덕원;김원기;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.727-730
    • /
    • 1988
  • In this paper, cardiac parameters and relationship between stroke volume and impedance change were explained, and an impedance cardiograph was designed and constructed, and its accuracy was verified by experiment. Useful cardiac parameters such as stroke volume and contractility of cardiac muscle were measured noninvasively. The reproducibility of the instrument was measured to be better(less than 10%) than that of clinical standard method such as thermodilution. Hence impedance cardiography was found to be better technique for monitoring stroke volume and contractility of patients for pre and post operation, and pharmacological studies.

  • PDF

Current Trend of Robotic Thoracic and Cardiovascular Surgeries in Korea: Analysis of Seven-Year National Data

  • Kang, Chang Hyun;Bok, Jin San;Lee, Na Rae;Kim, Young Tae;Lee, Seon Heui;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • 제48권5호
    • /
    • pp.311-317
    • /
    • 2015
  • Background: Robotic surgery is an alternative to minimally invasive surgery. The aim of this study was to report on current trends in robotic thoracic and cardiovascular surgical techniques in Korea. Methods: Data from the National Evidence-based Healthcare Collaborating Agency (NECA) between January 2006 and June 2012 were used in this study, including a total of 932 cases of robotic surgeries reported to NECA. The annual trends in the case volume, indications for robotic surgery, and distribution by hospitals and surgeons were analyzed in this study. Results: Of the 932 cases, 591 (63%) were thoracic operations and 340 (37%) were cardiac operations. The case number increased explosively in 2007 and 2008. However, the rate of increase regained a steady state after 2011. The main indications for robotic thoracic surgery were pulmonary disease (n=271, 46%), esophageal disease (n=199, 34%), and mediastinal disease (n=117, 20%). The main indications for robotic cardiac surgery were valvular heart disease (n=228, 67%), atrial septal defect (n=79, 23%), and cardiac myxoma (n=27, 8%). Robotic thoracic and cardiovascular surgeries were performed in 19 hospitals. Three large volume hospitals performed 94% of the case volume of robotic cardiac surgery and 74% of robotic thoracic surgery. Centralization of robotic operation was significantly (p<0.0001) more common in cardiac surgery than in thoracic surgery. A total of 39 surgeons performed robotic surgeries. However, only 27% of cardiac surgeons and 23% of thoracic surgeons performed more than 10 cases of robotic surgery. Conclusion: Trend analysis of robotic and cardiovascular operations demonstrated a gradual increase in the surgical volume in Korea. Meanwhile, centralization of surgical cases toward specific surgeons in specific hospitals was observed.

전기적 임피던스 방법을 통한 hand-held 타입의 심박출량 모니터링 시스템 개발 및 검증 (Development and Verification of a Hand-held Typed Monitoring System for Cardiac Output Measurement using Electrical Impedance Technique)

  • 서광석;심명헌;김민용;윤찬솔;정주홍;박성빈;윤형로
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1932-1938
    • /
    • 2012
  • The impedance cardiogram has been proposed as a non-invasive, continuous, operator independent, and cost-effective method for cardiac output monitoring. However, it can not be completely considered as non-restrictive method because of attached spot and band type electrodes. Therefore, we developed a improved convenient hand-held typed measurement system for cardiac output by electrical impedance technique. 80 subjects from Yonsei University and the surrounding areas, participated. All subjects measured stroke volume and cardiac output through Physioflow and developed system. To verify the developed system, statistical methods such as correlation, Wilcoxon signed ranks test, and the Bland-Altman analysis were used. The proposed system showed significant correlation in both male and female stroke volume(r=0.715, r=0.704) and cardiac output(r=0.826; r=0.804). From these results, it can be concluded that stroke volume and cardiac output could be improved convenient measurement using the both hands without the help of a specialist.

Time Course of Ventricular Remodeling after Atrial Septal Defect Closure in Adult Patients

  • Bae, Yo Han;Jang, Woo Sung;Kim, Jin Young;Kim, Yun Seok
    • Journal of Chest Surgery
    • /
    • 제54권1호
    • /
    • pp.45-52
    • /
    • 2021
  • Background: Atrial septal defect (ASD) is the most common congenital heart disease. However, the details of cardiac chamber remodeling after surgery are not well known, although this is an important issue that should be analyzed to understand long-term outcomes. Methods: Between November 2017 and January 2019, cardiac magnetic resonance imaging was performed preoperatively, at a 1-month postoperative follow-up, and at a 1-year postoperative follow-up. Cardiac chamber volume, valve regurgitation volume, and ejection fraction were measured as functions of time. Results: Thirteen patients (10 men and 3 women) were included. The median age at surgery was 51.4 years. The preoperative median ratio of flow in the pulmonary and systemic circulation was 2.3. The preoperative mean right ventricular (RV) end-diastolic volume index (EDVi) and RV end-systolic volume index (ESVi) had significantly decreased at the 1-month postoperative follow-up (p<0.001, p=0.001, respectively). The decrease in the RVEDVi (p=0.085) and RVESVi (p=0.023) continued until the postoperative 1-year follow-up, although the rate of decrease was slower. Tricuspid valve regurgitation had also decreased at the 1-month postoperative follow-up (p=0.022), and continued to decrease at a reduced rate (p=0.129). Although the RVEDVi and RVESVi improved after ASD closure, the RV volume parameters were still larger than the left ventricular (LV) volume parameters at the 1-year follow-up (RVEDVi vs. LVEDVi: p=0.016; RVESVi vs. LVESVi: p=0.001). Conclusion: Cardiac remodeling after ASD closure is common and mainly occurs in the early postoperative period. However, complete normalization does not occur.