• Title/Summary/Keyword: Carbonization patterns

Search Result 15, Processing Time 0.017 seconds

A Study on the Analysis of the Combustion Behavior and Carbonization Pattern of Vinyl Flooring on Which a Real-Scale Combustion Test Was Performed (실물 연소 실험이 진행된 비닐장판의 연소거동 및 탄화 패턴 해석에 관한 연구)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.120-125
    • /
    • 2019
  • A real-scale combustion test was conducted on a vinyl flooring in a divided space, with 50 mL of an inflammable liquid sprayed on it. The combustion behavior of the vinyl flooring was studied in real time, and the carbonization patterns of the surface and cross-sections of the carbonized vinyl floor were analyzed. When the flame ignited by gasoline reached its peak, a continuously flaming region, intermittent flaming region, plume region, etc., were formed. The combustion of 50 mL gasoline on vinyl flooring took 26 s, and a halo pattern was observed. This test involved spraying kerosene evenly on the vinyl flooring and attempting to ignite the flooring using a gas torch, which failed. After the combustion of the vinyl flooring was complete, its carbonized range was measured to be 600 mm in length and 380 mm in width, and the carbonized area was 1000 ㎟. Heat transformed the coated layer of surface of the carbonized vinyl flooring into a carbonized layer, which became harder. The analysis of cross-section of the boundary surface of the carbonized vinyl flooring using a stereoscopic microscope showed that the vinyl flooring was bubbling, and that the white boundary layer at the bottom of the coated layer had disappeared.

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

Analysis of the Damage Patterns and Metal Structure of 3 Phase Mold Transformers to which Interlayer Short-circuits have Occurred (층간 단락된 3상 몰드변압기의 소손 패턴 및 금속 조직 해석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.86-91
    • /
    • 2010
  • The purpose of this study is to analyze the damage patterns and metal structure of 3 phase mold transformers collected from places where accidents have occurred. Compared to an oil-immersed transformer, a mold transformer has the advantage of requiring a smaller installation area and can be kept clean, while its disadvantages include the fact that abnormal symptoms of an accident are difficult to discover and its repair is impossible. The capacity of the mold transformers collected from places where accidents have occurred was 200kVA with primary voltages being F23,900V, R22,900V, 21,900V, 20,900V, 19,900V, etc., as well as secondary voltages being 380V, 220V, etc. It was found from the analysis on the diffusion of combustion in the damaged mold transformers that fire occurred first inside the U-phase primary winding and that carbonization and heat were diffused to V-phase and W-phase in V-pattern. In addition, from the analysis on the cross-sectional structure of the metal of the melted high voltage winding using a metallurgical microscope, it was found that the boundary surface, voids, and columnar structure were formed when an interlayer short-circuit had occurred Therefore, even though it is not possible to find the cause for the occurrence of an interlayer short-circuit at the inner side of the primary winding, it is thought that, due to the thermal energy generated when the short-circuit occurred, the heat source was diffused to the upper side and outside, causing a secondary accident.

Optimization of hydrochar generated from real food waste using titration methods (음식물폐기물-하이드로촤 최적 반응조건 도출을 위한 적정법 응용)

  • Choi, Minseon;Choi, Seong-Eun;Han, Sol;Bae, Sunyoung
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.40-46
    • /
    • 2015
  • Hydrochar has been generated from food waste via hydrothermal carbonization (HTC) reaction. As a solid product of HTC reaction, hydrochar has a great potential as an adsorbent of pollutants from the various media. The surface area and pore volumes are very important parameters to be served as an adsorbent. It requires an expensive equipment and consumes time to measure those parameter. Therefore, titration methods including iodine and methylene blue adsorption were evaluated to be correlated with that of BET analysis. Even though the absolute values of the computed surface area and pore volumes were not able to be matched directly, the patterns of change were successfully correlated. Among the reaction conditions, the reaction time and temperature at $230^{\circ}C$ for 4 h was determined as an optimization condition, which confirmed by titration method and BET analysis. Titration method for surface area and pore volumes computed by combination of iodine and methylene blue adsorbing values would be a simple and fast way of determining the optimization condition for hydrochar as an adsorbent produced by HTC reaction.

Analysis on Composition and Strength of Lime-Soil Mixture Barrier Tombs at Guri Galmae Site in Joseon Dynasty (조선시대 구리 갈매유적 회곽묘의 조성 및 강도분석)

  • Lee, Chan Hee;Eo, Eon Il;Shin, Sook Chung
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.2
    • /
    • pp.40-61
    • /
    • 2017
  • This study investigated material characteristics of composition and variable strength measurement using physicochemical and petrographic analysis for lime-soil mixture barrier tombs of Guri Galmae site in Joseon Dynasty. The tomb barriers are composed mainly of microcrystalline calcite, quartz, feldspar and mica with lime matrix. The lime matrix shows compact sheet texture, and some samples show hydration aggregates with needle-shaped textures. Gypsum occurred as a secondary process where carbonization reactions were poor. Concentrations of CaO in the tomb barrier very widely ranged from 4.43 to 36.19 wt.%, specific gravity and absorption ratio of the materials show of 1.35 to 1.62 and 20.1 to 32.6%, respectively. As the rebound hardness, the materials ranged from 10.0 to 28.4 (mean 15.7). The values are higher in the $-90^{\circ}$ direction rather than in the $0^{\circ}$ direction with the consequence that the values indicate more strength toward the vertical direction. Difference in strength by directions was caused by the directions of the tomb barriers, which is related to the processes in each stage. In the tomb barriers, ultrasonic velocity and unconfined compressive strength ranged from 1,049.2 to 1,728.9m/s and under 5.00MPa, respectively. Variation patterns between the two are very similar in values. As the result of composition and strength, the materials of higher contents on CaO are higher in strength values. Generally, techniques and skills to make the lime-soil mixture barriers are interpreted as low qualities in relatively.