• Title/Summary/Keyword: Carbon-monoxide

Search Result 1,001, Processing Time 0.03 seconds

Effect of pH and Temperature on the Electrochemical Reduction of Carbon Dioxide by Carbon Monoxide Dehydrogenase (일산화탄소탈수소화효소를 이용한 이산화탄소의 전기화학적 환원에 미치는 pH와 온도의 영향)

  • Shin, Jun-Won;Kim, You-Sung;Lee, Sang-Hee;Lee, Sang-Phil;Lee, Ho-Jun;Lim, Mi-Ran;Song, Ji-Eun;Shin, Woon-Sup
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.265-269
    • /
    • 2007
  • The effects of experimental variables for the electrochemical reduction of carbon dioxide by Carbon Monoxide Dehydrogenase (CODH) were investigated. It shows the pH optimum at 6.3 where the feasibility of electro-chemical reduction and the stability of CODH compromise each other. The optimum temperature for the reduction was at $60^{\circ}C$ where the enzyme shows the optimum activity although the solubility of carbon dioxide decreases as increasing temperature.

Preparation and Application of Fiber Composites made of Carbon Nanofibers and Carbide Nanofibers (나노탄소섬유와 나노카바이드섬유를 이용한 복합재의 제조와 활용에 관한 연구)

  • 임연수;김기덕;이재춘;김명수;김성수
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.6
    • /
    • pp.569-575
    • /
    • 2000
  • Fabrication of carbon fiber reinforced composites was carried out by hand lay-up method. Carbon nanofibers and SiC nanofibers were used as filler in the composites fabrication. Carbon nanofibers, one of the new carbon materials, have 5∼500 nm in diameter and 5-10 nm in length. SiC nanofibers were modified by silicon monoxide vapor with carbon nanofibers. The composites were carbonized at 1000$^{\circ}C$ in a nitrogen atmosphere, and then densified by molten pitches impregnated in vacuum. Multiple cycles of liquid pitch impregnation and carbonization were carried out to obtain a desired density. The composites were characterized by density, microstructure. The inter-laminar shear strength (ILSS) test was performed for mechanical properties. For the new application, the microwave reflective proeprty of composites was investigated. Dielectric constant and permeability spectrum were measured in 12∼18 GHz frequency ranges. On the basis of the wave propagation theory in a lossy media, the reflection loss from the composite inter-layer was predict as a function of frequency.

  • PDF

Emission of Carbon Monoxide and Carbon Dioxide Gases during Fire Tests of Specimens Treated with Phosphorus-Nitrogen Additives (인-질소 첨가제로 처리된 시험편의 연소 시에 발생하는 일산화탄소와 이산화탄소 생성)

  • Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.609-614
    • /
    • 2015
  • This study was to investigate the production of combustion toxic gases of pinus rigida specimens treated with pyrophosphoric acid (PP)/4ammonuium ion ($4NH_4{^+}$), methylenepiperazinomethyl-bis-phosphonic acid (PIPEABP) and PIPEABP/$4NH_4{^+}$. Each pinus rigida plates was painted in three times with 15 wt% in the aqueous solution followed by drying the species at room temperature. Emission of combustion toxic gases was examined by the cone calorimeter (ISO 5660-1). First-time to peak mass loss rate (1st-$TMLR_{peak}$) treated with chemicals was delayed upto 66.7~250.0% compared to those of untreated specimens. For test pieces treated with the chemicals, the emission of peak carbon monoxide ($CO_{peak}$) values of 0.0136~0.0178% and peak carbon dioxide ($CO_{2\;peak}$) value of 0.04432~0.3648% were obtained, which were higher than those for the virgin plate. In particular, oxygen emission is much higher than the level of 15% which can be fatal to humans. Therefore, the resulting risk could be eliminated. However it is supposed that the combustion-toxicities were partially increased compared to those of virgin plate.

The Assessment and Recognition on Indoor Air Quality at Schools in Korea (전국 일부 학교 건축물 내의 실내 공기 및 인식도 조사)

  • Sohn Jong-Ryeul;Yoon Seung-Uk;Kim Jong-Hyuk;Lee Yong-Sik;Choi Han-Young;Kim Young-Sung;Son Bu-Soon;Yang Won-Ho;Kim Min-Hoi
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.1-9
    • /
    • 2005
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the healthy effectsrelated to IAQ, specially in schools in Korea. Therefore, objectives of this study in this study were to measure and compare the perception of TAQ of selected air pollutants in Seoul from April to September 2004. Measurement place measured 2 schools of Seoul and local 9 schools (by Kyonggi Province, Chungchong-bukdo Chungchong-namdo, Chollado-bukdo, Cholla-namdo, Kyongsang-bukdo, Kyongsang-namdo, Kwangju, schoolin Pusan each 1 place). Temperature, humidity, illumination, carbon monoxide, carbon dioxide, TBC (total bacteria count), noise, PM10, TVOC(total volatile organic compounds), HCHO (formaldehyde) were measured simultaneously. Also, we Performed a questionnaire survey of 250 students and 50 teachers about their awareness for the importance of IAQ in their schools. Among this article, we handled noise, carbon monoxide, carbon dioxide, TBC, TVOC, HCHO, PM 10 in our conclusion. Major results were as follows ; Carbon monoxide (CO) was lower than indoor air standard of Korea. Carbon dioxide $(CO_2)$ appeared that 4 schools among our sample target school exceeded in normal standard. 4 schools were almost similar with normal standard. TBC appeared that 7 schools among 11 schools were higher than standard. Noise measured school's mean value passed exceeded standard. And school which passed over standard appeared to 7 schools among 11 schools. HCHO was exceeded 4 schools by standard that excess and certainly interrelation between school's establishment year and facilities of construction was detected. PM10 was exposed all schools by fitness in standard. TVOC appeared that 9 schools among 11 measurement school was exceeded health effect standard of Japan.

A Study of the Formation of Carbon Monoxide in the Combustion of Anthracite Holed Briquettes (연탄이 연소할 때에 생성되는 일산화탄소에 대한 연구)

  • Han, Dong-Chin
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.150-158
    • /
    • 1967
  • When anthracite burns by natural draft the mole percent of carbon monoxide (CO%) contained in exhaust gas is approximately expressed as follows in the early stage of combustion. (CO%)=$\frac{2{\alpha}}{1+{\alpha}}(CO_2%)$ exp $[-\vec{k}(No_2-Nc)^{1/2}{\tau}]$ where ${\alpha}=\frac{-0.395K_p+\sqrt{0.156K^2_p+(0.83+0.21K_p)K_p}}{0.83+0.21K_p}$ and $logK_p =-\frac{8593}{T} + 2.45logT -1.08{\times}10^{-3}T + 1.12{\times}10^{-7}T^2+2.77\vec{k},\;No_2$ and $N_c$ are the rate constant for the reaction ($CO+\frac{1}{2}O_2{\to}CO_2$), mole fraction of oxygen and oxides of carbon contained in the exhaust gas, respectively. From experimental evidence obtained in this work with natural draft combustion of briquettes the percent of carbon monoxide to the total quantity of oxides of carbon produced and rate of air flow into the furnace were: 1.76% and 0.53 l/sec (When lid is used in the furnace) 12.35% and 2.4 l/sec (without use of a lid). is the rate constant for the reaction($CO+\frac{1}{2}O_2{\to}CO_2$) and $N_0,\;and\;N_c$ are respectively the molefraction of oxygen and oxide of carbon contained in the exhaust gas.

  • PDF

The Prediction of Emission Concentrations in SI Engine Considering Temperature Gradient in Combustion Chamber (전기점화기관의 연소실 온도구배를 고려한 배출물 농도예측)

  • 신동신;김응서
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.3
    • /
    • pp.83-93
    • /
    • 1985
  • The prediction of emission concentrations in a 4cycle spark ignition engine was made by considering nonuniform model with thermodynamics, chemical equilibrium and kinetic mechanism of nitric oxide. Calculation of this model shows that a temperature difference of the order of 500K can be established across he cylinder. Results of the kinetic calculation of nitric oxide show that the temperature gradient across the cylinder has a profound effect on the nitric oxide formation. The predicted values for nitric oxide, carbon dioxide and carbon monoxide agree with measured ones for a variety of equivalence ratio.

  • PDF

Electrocatalytic Reduction of Carbon Dioxide on Sn-Pb Alloy Electrodes

  • Choi, Song Yi;Jeong, Soon Kwan;Park, Ki Tae
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.231-236
    • /
    • 2016
  • Electrocatalytic reduction can produce useful chemicals and fuels such as carbon monoxide, methane, formate, aldehydes, and alcohols using carbon dioxide, the green house gas, as a reactant through the supply of electrical energy. In this study, tin-lead (Sn-Pb) alloy electrodes are fabricated by electrodeposition on a carbon paper with different alloy composition and used as cathode for electrocatalytic reduction of carbon dioxide into formate in an aqueous system. The prepared electrodes are measured by Faradaic efficiency and partial current density for formate production. Electrocatalytic reduction experiments are carried out at -1.8 V (vs. Ag/AgCl) using H-type cell under ambient temperature and pressure and the gas and liquid products are analyzed by gas chromatograph and liquid chromatograph, respectively. As results, the Sn-Pb electrodes show higher Faradaic efficiency and partial current density than the single metal electrode. The Sn-Pb alloy electrode which have Sn:Pb molar ratio=2:1, shows the highest Faradaic efficiency of 88.7%.

Production of Carbon Monoxide and Carbon Dioxide Gases in the Combustion Tests (연소 시험에서 발생하는 일산화탄소와 이산화탄소의 발생)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.7-13
    • /
    • 2015
  • This study was performed to test the production of combustion toxic gases by Pinus rigida specimens treated with various types of methylpiperazinomethyl-bis-phosphonic acid $M^{n+}$ ($PIPEABPM^{n+}$) and methylpiperazinomethyl-bis-phosphonic acid (PIPEABP). Three coats of 15 wt% $PIPEABPM^{n+}$ and PIPEABP solutions were applied to plates of Pinus rigida at room temperature. After drying the treated specimens, the production of combustion toxic gases was examined using a cone calorimeter (ISO 5660-1). The specimens treated with $PIPEABPM^{n+}$ showed lower carbon monoxide production ($CO_{2\;peak}$; 0.0136~0.0178% at 532~678 s) than the PIPEABP plates, except for the specimen treated with $PIPEABPFe^{3+}$. In addition, the peak carbon dioxide production ($CO_{2\;peak}$) was lower (0.03648~0.3648% at 373~433 s) than that of the PIPEABP-treated plate. Notably, oxygen production was much higher than 15%, which can be fatal to humans. Therefore, the resulting risk could be eliminated. The results indicate that the combustion toxicities were partially decreased due to treatment of the virgin plate with $PIPEABPM^{n+}$.