• 제목/요약/키워드: Carbon concentration

검색결과 3,801건 처리시간 0.028초

Electrosorption of Uranium Ions in Liquid Waste

  • Lee, Hye-Young;Jung, Chong-Hun;Oh, Won-Zin;Park, Jin-Ho;Shul, Yong-Gun
    • Carbon letters
    • /
    • 제4권2호
    • /
    • pp.64-68
    • /
    • 2003
  • A study on the electrosorption of uranium ions onto a porous activated carbon fiber (ACF) was performed to treat uraniumcontaining lagoon sludge. The result of the continuous flow-through cell electrosorption experiments showed that the applied negative potential increased the adsorption kinetics and capacity in comparison to the open-circuit potential (OCP) adsorption for uranium ions. Effective U(VI) removal is accomplished when a negative potential is applied to the activated carbon fiber (ACF) electrode. For a feed concentration of 100 mg/L, the concentration of U(VI) in the cell effluent is reduced to less than 1 mg/L. The selective removal of uranium ions from electrolyte was possible by the electrosorption process.

  • PDF

귀금속촉매 (Pt, Pd)를 이용한 일산화탄소 산화반응에 관한 연구 (A Study of Carbon Monoxide Oxidation on Pt & Pt-Pd Catalysts)

  • ;이원묵;유홍진
    • 한국대기환경학회지
    • /
    • 제1권1호
    • /
    • pp.43-51
    • /
    • 1985
  • This study is concerned with the oxidation of carbon monoxide on platinum and platinum-palladium catalysts. Catalysts were made by the impregnation method and flow reactor was used in the catalytic reaction. As for the mixed gases, carbon monoxide concentration varied from 1 to 4% and that of oxygen from 1 to 4%. $N_2$ was used as carrier gas and GHSV varied from 24, 000 $h^{-1} to 60, h^{-1}$. The temperature range was from 200 to $600^\circ$C. It was also taken into consideration that the heat and mass transfer resistance of our catalysts was negligible in the study. Experimental results showed that platinum-palladium catalyst was about 1.5-3.9% superior to platinum catalyst in conversion yield. When we used platinum-palladium catalyst, we observed that carbon monoxide oxidation was found to be 1 st order with respect to carbon monoxide concentration. Activation energy of the catalyst was 23.5 kcal/mol.

  • PDF

SPUTTER-DEPOSITION OF CARBON NITRIDE FILMS WITH HIGH NITROGEN CONCENTRATION

  • Taki, Yusuke;Takai, Osamu
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.498-504
    • /
    • 1996
  • The synthesis of carbon nitride thin films with high nitrgen concentration was accomplished by reactive supttering at relatively high working pressure. In conventional reactive sputter-deposition of carbon nitride films, working pressure was 0.3-5Pa and the ratio of nitrogen to carbon(N/C ratio) in the films was less than 0.5. In this study, amorphous carbon nitride films with the N/C ratio $\tickapprox$ 1.0 were prepared on Si(100). substrates at higher pressure, 20-60 Pa. Structural analyses with Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy revealed that the films prepared consisted of triazine-like plain network.

  • PDF

입상 활성탄의 물리적특성 변화에 따른 흡착특성 (The Adsorption Characteristics of a Granular Active Carbon by the Physical Properties)

  • 김덕기;신창섭
    • 한국안전학회지
    • /
    • 제11권1호
    • /
    • pp.84-89
    • /
    • 1996
  • The adsorption characteristics of active carbon used as a cartridge filler of organic vapor respirator were examined by humidity, particle size, challenge concentration and specific surface area. As a result, the 1% breakthrough time of Carbon Tetrachloride($CCl_4$) was decreased with increase of relative humidity, challenge concentration and particle size (0.6~2.0mm) of active carbon. The adsorbed amount of $CCl_4$ was about 1. 1mg/$m^2$ at RH 40% and 0. 5mg/$m^2$ at RH 80% . However in the case of prehumidified active carbon, humidity did not affected to 1% breakthrough time up to RH 40%.

  • PDF

Correlation between Carbon Steel Corrosion and Atmospheric Factors in Taiwan

  • Lo, C.M.;Tsai, L.H.;Hu, C.W.;Lin, M.D.
    • Corrosion Science and Technology
    • /
    • 제17권2호
    • /
    • pp.37-44
    • /
    • 2018
  • Taiwan has a typical marine climate featuring perennial high-temperature and dampness. This climate, together with the emission of various industrial corrosive waste gases in recent years, contributes a lot to the corrosion of metal materials. In this study, samples of carbon steel exposed to various atmospheres in Taiwan were analyzed to investigate the impacts of atmospheric factors on carbon steel corrosion. Carbon steel samples were collected from 87 experimental stations between 2009 and 2012. Statistical analysis was employed to investigate the correlations between the carbon steel corrosion situations and the atmospheric factors such as concentrations of sulfur dioxide or chloride, exposure time, rainfall, etc. The results indicate that for samples from industrial areas, the sulfur dioxide concentration and exposure time during fall and winter are significantly correlated to the condition of the carbon steel corrosion. However, for samples from coastal zones, the significant correlated factors are chloride concentration and wetting time during winter. The results of this study are useful for the development of carbon steel corrosion prediction models.

PTFE 입자 크기 변화와 Carbon Paper 발수 코팅 특성 변화 (Characteristics of Coated Carbon Paper with PTFE Emulsion Have Different Particle Size)

  • 전현;송기세;정문국;이혜민;조태환;최원경
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.424-431
    • /
    • 2009
  • Treatment for water repellency on the carbon supports of GDL which composed a part of MEA has been suggested as a solution to prevent flooding. PTFE is a fluoropolymer that has hydrophobic property and a PTFE emulsion was selected as waterproof agent in this investigation. Carbon paper was coated by PTFE emulsion with different particle size of 5~500 nm and 3~$5\;{\mu}m$ as various concentration. PTFE coated carbon paper has difference in weight variation changed proportionally at PTFE concentration and coating times. Then gas permeability of the coated carbon paper with emulsion of 3~$5\;{\mu}m$ PTFE was changed vastly. Characteristics of carbon paper coated with different PTFE emulsion were analyzed by FE-SEM, FT-IR spcetroscopy and were evaluated by weight variations, gas permeability and water contact angle.

Modifications of mechanical, thermal, and electrical characteristics of epoxy through dispersion of multi-walled carbon nanotubes in supercritical carbon dioxide

  • Zaidi, M.G.H.;Joshi, S.K.;Kumar, M.;Sharma, D.;Kumar, A.;Alam, S.;Sah, P.L.
    • Carbon letters
    • /
    • 제14권4호
    • /
    • pp.218-227
    • /
    • 2013
  • A supercritical carbon dioxide (SCC) process of dispersion of multi-walled carbon nanotubes (MWCNTs) into epoxy resin has been developed to achieve MWCNT/epoxy composites (CECs) with improved mechanical, thermal, and electrical properties. The synthesis of CECs has been executed at a MWCNT (phr) concentration ranging from 0.1 to 0.3 into epoxy resin (0.1 mol) at 1800 psi, $90^{\circ}C$, and 1500 rpm over 1 h followed by curing of the MWCNT/epoxy formulations with triethylene tetramine (15 phr). The effect of SCC treatment on the qualitative dispersion of MWCNTs at various concentrations into the epoxy has been investigated through spectra analyses and microscopy. The developed SCC assisted process provides a good dispersion of MWCNTs into the epoxy up to a MWCNT concentration of 0.2. The effects of SCC assisted dispersion at various concentrations of MWCNTs on modification of mechanical, thermal, dynamic mechanical thermal, and tribological properties and the electrical conductivity of CECs have been investigated.

Temperature Dependence on Structural, Tribological, and Electrical Properties of Sputtered Conductive Carbon Thin Films

  • Park, Yong-Seob;Hong, Byung-You;Cho, Sang-Jin;Boo, Jin-Hyo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.939-942
    • /
    • 2011
  • Conductive carbon films were prepared at room temperature by unbalanced magnetron sputtering (UBMS) on silicon substrates using argon (Ar) gas, and the effects of post-annealing temperature on the structural, tribological, and electrical properties of carbon films were investigated. Films were annealed at temperatures ranging from $400^{\circ}C$ to $700^{\circ}C$ in increments of $100^{\circ}C$ using a rapid thermal annealing method by vacuum furnace in vacuum ambient. The increase of annealing temperature contributed to the increase of the ordering and formation of aromatic rings in the carbon film. Consequently, with increasing annealing temperature the tribological properties of sputtered carbon films are deteriorated while the resistivity of carbon films significantly decreased from $4.5{\times}10^{-3}$ to $1.0{\times}10^{-6}\;{\Omega}-cm$ and carrier concentration as well as mobility increased, respectively. This behavior can be explained by the increase of sp2 bonding fraction and ordering $sp^2$ clusters in the carbon networks caused by increasing annealing temperature.

Hevea brasiliensis - A Biosorbent for the Adsorption of Cu(II) from Aqueous Solutions

  • Sivarajasekar, N.
    • Carbon letters
    • /
    • 제8권3호
    • /
    • pp.199-206
    • /
    • 2007
  • The activated carbon produced from rubber wood sawdust by chemical activation using phosphoric acid have been utilized as an adsorbent for the removal of Cu(II) from aqueous solution in the concentration range 5-40 mg/l. Adsorption experiments were carried out in a batch process and various experimental parameters such as effect of contact time, initial copper ion concentration, carbon dosage, and pH on percentage removal have been studied. Adsorption results obtained for activated carbon from rubber wood sawdust were compared with the results of commercial activated carbon (CAC). The adsorption on activated carbon samples increased with contact time and attained maximum value at 3 h for CAC and 4 h for PAC. The adsorption results show that the copper uptake increased with increasing pH, the optimum efficiency being attained at pH 6. The precipitation of copper hydroxide occurred when pH of the adsorbate solution was greater than 6. The equilibrium data were fitted using Langmuir and Freundlich adsorption isotherm equation. The kinetics of sorption of the copper ion has been analyzed by two kinetic models, namely, the pseudo first order and pseudo second order kinetic model. The adsorption constants and rate constants for the models have been determined. The process follows pseudo second order kinetics and the results indicated that the Langmuir model gave a better fit to the experimental data than the Freundlich model. It was concluded that activated carbon produced using phosphoric acid has higher adsorption capacity when compared to CAC.

Development and Evaluation of Impregnated Carbon Systems Against Iodine Vapours

  • Srivastava, Avanish Kumar;Saxena, Amit;Singh, Beer;Srivas, Suresh Kumar
    • Carbon letters
    • /
    • 제8권4호
    • /
    • pp.274-279
    • /
    • 2007
  • In order to understand the breakthrough behaviour of iodine vapours on impregnated carbon systems, an active carbon, 80 CTC grade, $12{\times}30$ BSS particle size and $1104\;m^2/g$ surface area, was impregnated with metal salts such Cu, Cr, Ag, Mo and Zn, and an organic compound Triethylene diamine (TEDA) to prepare different carbon systems such as whetlerite, whetlerite/TEDA, whetlerite/KI/KOH and ASZMT. The prepared adsorbents along with active carbon were characterized for surface area and pore volume by $N_2$ adsorption at liquid nitrogen temperature. These carbon systems were compared for their CT (concentration X time) values at 12.73 to 53.05 cm/sec space velocities and 2 to 5 cm carbon column bed heights. The carbon column of 5.0 cm bed height and 1.0 cm diameter was found to be providing protection against iodine vapours up to 5.5 h at 3.712 mg/L iodine vapour concentration and 12.73 cm/sec space velocity. The study clearly indicated the adsorption capacities of carbon systems to be directly proportional to their surface area values. Dead layer with all the prepared carbon systems was found to be less than 2.0 cm indicating it to be minimum bed height to have protection against $I_2$ vapours. Effect of carbon bed height and flow rate was also studied. The active carbon showed maximum protection at all bed heights and flow rates in comparison to all other impregnated carbon systems, showing that only physical adsorption is responsible for the removal of iodine vapours.