• 제목/요약/키워드: Carbide Tool

검색결과 236건 처리시간 0.024초

특허(特許)와 논문(論文)으로 본 텅스텐카바이드(WC) 재활용(再活用) 기술(技術) 동향(動向) (Trend on the Recycling Technologies for the used Tungsten Carbide(WC) by the Patent and Paper Analysis)

  • 정진기;이재천;박상우;강경석
    • 자원리싸이클링
    • /
    • 제21권1호
    • /
    • pp.82-92
    • /
    • 2012
  • 텅스텐카바이드는 금속절단 공구, 드릴의 날, 광산공구, 군사무기 재료, 화학원료, 촉매, 내마모성재료, 제트엔진 터빈 블레이드 등 다양한 용도로 사용된다. 요즘 경제적인 측면과 효율적인의 측면에서 텅스텐카바이드 재활용 기술이 넓게 연구되었다. 이 논문에서는 텅스텐카바이드 재활용 기술에 대하여 1969년부터 2011년까지 공개/등록된 미국, 일본, 유럽, 한국의 특허와 SCI급 논문을 조사하였다. 키워드를 이용하여 조사하였고 필터링 하여 특허와 논문을 수집하여 연도별, 국가별, 기관별, 기술별로 분석하였다.

자종공무마모계측시스템개발 (System Development for Automatic Tool Wear Measurement)

  • Kim, Y.I.
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.185-199
    • /
    • 1994
  • This study has been performed to present a new automatic tool wear measurement by digital image processing. The purpose of this paper is to develop an automatic tool wear measuring system based on the image processing which can be applied to the quasi-real time measurement of the characteristics of insert tip in turning. Tool wear monitoring is one of the key-problems, for the development of control systems of modern unmanned factory which are not completely solved now. In oredr words at present complete qualitative and quantitative information on tool wear morphology is required, at least on the following aspects : flank wear, its dimensions and distribution on the maximum and mean values on VB pqrqmeter in the various zones of the wearland. crater wear, its main dimensions and values of KT parameters. This research has been performed to this technique made possible by designing a proper lighting system to the worn tool with following features : The flank wear is measured by observing the active cutting part from a proper direction and by lighting the wearland by a diffuser optic system. The crater wear is visualized by lighting the tool by a He-Ne gas laser system developed in this study. By means of this system it is research to evaluate classical parameters of tool wear and to have complete information about tool wear morphology.

  • PDF

초경 엔드밀의 플라즈마 이온 주입과 저온 열처리를 통한 내마멸성 향상 (Enhancement of Wear Resistance by Low Heat Treatment and the Plasma Source Ion Implantation of Tungsten Carbide Tool)

  • 강성기;왕덕현;김원일
    • 한국생산제조학회지
    • /
    • 제20권2호
    • /
    • pp.162-168
    • /
    • 2011
  • In this research, nitrogen plasma source ion implantation(PSII) of non-coated tungsten carbide endmill tools was conducted with low heat treatment for increasing wear resistance. After the low heat treatment of PSIIed tools to give a homogeneity of wear resistance, the surface modification of tools was analyzed by hardness test, surface roughness and cutting forces. As for the resultant cutting forces, low heat treatment in temperature of $400^{\circ}C$ and $500^{\circ}C$ is stable because of low cutting resistance. The 20-minutes heat treated tool at spindle speed 25000rpm has superiority of surface roughness, Ra of $0.420{\mu}m$ and was found to have good wear resistance. The higher hardness value was obtained by increasing temperature from $300^{\circ}C$ to $600^{\circ}C$ for PSIIed tools with low heat treatment. As the PSIIed tools under 10minutes at temperature of $600^{\circ}C$ have the highest hardness as Hv of 2349.8, It was analyzed that temperature processing give much influences on hardness.

연속파형 Nd:YAG 레이저를 이용한 열간금형 공구강의 표면경화 특성 (Characteristics of Surface Hardening for Hot Work Tool Steel using Continuous Wave Nd:YAG Laser)

  • 신호준;신병헌;유영태
    • 한국정밀공학회지
    • /
    • 제24권4호
    • /
    • pp.57-67
    • /
    • 2007
  • Laser surface hardening technologies have been used to improve characteristics of wear and to enhance the fatigue resistance fur mold parts. The objective of this research work is to investigate the influence of the process parameters, such as power of laser and defocused spot position, on the characteristics of laser surface hardening for the case of SKD61 steel. CW Nd:YAG laser is selected as the heat source. The optical lens with the elliptical profile is designed to obtain a wide surface hardening area with a uniform hardness. From the results of the experiments, it has been shown that the maximum average hardness is approximatly 780 Hv when the power, focal position and the travel of laser are 1,095 W, 0mm and 0.3 m/min, respectively. In samples treated with lower scanning speeds, some small carbide particles appear in the interdendritic regions. This region contains fine martensite and carbide in proportions which depend on the local thermal cycle.

흑연소재가공용 공구의 DLC 코팅두께가 가공특성에 미치는 영향 (Effect on Tooling Characteristics to DLC-coated Thickness of Tool for Graphite Material)

  • 윤재호;김형균;최성대
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.22-27
    • /
    • 2015
  • Processing of low toughness graphite material requires high-speed machine tools and DLC coating. In this study, results of investigation of the tool wear and machining properties of the DLC coating according to the thickness, and the machining time of the tool used for the machining of graphite electrodes, were as follows. 1. DLC coating thickness shows a larger wear amount of the tool center in accordance with thickness; the wear amount of the tool increases in proportion to the machining time. 2. The difference between the amount of wear depending on the processing time shows edge portions larger than the tool wear amount in the center. This amount of wear of the tool edge is formed since the rotating torque is in contact with the graphite material surface significantly more than the central portion. 3. The thicker the DLC coating, the more the coating tool eliminated of the coating area by the interface between the cemented carbide tool being coated with an increased friction of the graphite material and the DLC coating area.

냉간 단조용 금형 수명 및 단조품 품질 향상을 위한 금형 특성 연구 (Characteristics of tools for improving the tool life and forged product on cold forging)

  • 이영선;권용남;권용철;이정환;최석탁
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.125-126
    • /
    • 2006
  • The characteristics of the tool system give many effects into the costs and qualities for the finished components. Therefore, a tool life is one of the important issues on cold forging industry. However, since variables related with tool life are many complicated, the studies for solution should be investigated by the systematic research approach. In this study, heat-treatment of tool material is investigated to improve the tool life. Deep cryogenic treatment of tool steel is very efficient to improve the wear resistance due to the fine carbide. And, it is investigated that the shape and dimension of tool give effect into both tool life and quality of forged product.

  • PDF

플라즈마 이온주입에 의해 표면 개질한 초경공구의 가공특성 (Cutting Characteristics of Plasma Source Son Implanted Tungsten Carbide Tool)

  • 강성기;왕덕현;김원일
    • 한국정밀공학회지
    • /
    • 제27권1호
    • /
    • pp.33-40
    • /
    • 2010
  • In this research, the effects for surface Improvement of plasma ion implanted carbide endmill tools were observed by measuring cutting forces and tools wear affecting surface roughness in high speed cutting. From the 2nd ion mass analysis, the oxidation layer was found to be built up by sputtering. The residual gas contamination of oxygen was found to be contained impurities in nitrogen gas. The plasma implanted ion was found to be spreaded, especially the nitrogen was implanted up to 150nm depth as impressed voltage and ion implanting time. It is analyzed as bring surface improvement by spreading deeply forming oxidation on surface. The factors in Analysis of Variance(ANOVA) about mutuality cause reference of cutting force. The cutting force Fx is affected by the interaction of spindle rpm and federate, the cutting force Fy is influenced by spindle rpm and time injected ion, and cutting force Fz is affected by the interaction of impressed voltage and feedrate. Also, it was found that the cutting forces of implanted tools become lower and the surface roughness is improved by the effect of nitrogen according to the implantation.

유리섬유 강화 플라스틱 절삭시의 공구마멸 특성 (Characteristics of tool wear in cutting of glass fiber reinforced plastics)

  • 강명순;이원평
    • 대한기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.1055-1062
    • /
    • 1988
  • 본 연구에서는 역학모델을 이용해 공구마멸 특성을 절삭속뿐만 아니라 공구와 유리섬유의 접촉길이에 대해서도 논하고, 이 결과와 실험결과를 대비 검토하였다. 또 몇 가지 공구재종으로 절삭성능을 측정하였다.

초음파 가공에 의한 미세 에어홀 가공 기술 (Micro-machining of Glass Air Hole using Ultrasonic Machining)

  • 김병희;전성건;남권선;김헌영;전병희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.48-52
    • /
    • 2004
  • Ultrasonic machining is effective for machining of extreme hard and brittle materials, including glass, ceramic, carbide, graphite. The major machining principle involves the direct hammering as well as the impact of abrasive panicles on the workpiece. Also, it involve cavitation erosion. The general workpiece is flat side. This study attempted micro hole machining of a curved surface of glass tube. Ultrasonic machining is fault of the slow machining speed. An experiment does and got 16 seconds validity machining time as increasing the processing speed. Moreover, entrance crack and surface roughness was similar both machining speed is slow and fast. Several micro hole of glass tube machined using one micro tool, but tool wear is infinitesimal.

  • PDF